Evidence of microphase separation in controlled pore glasses.

The phase separation of a mixture of water and isobutyric acid (iBA) confined in the pore space of Controlled Pore Glass (CPG) 10-75 has been studied by 1H NMR relaxometry and 1H-pulsed field gradient (PFG) diffusion measurements. For an acid-rich mixture (mass fraction 54 wt% iBA), evidence of a phase separation process in the pores was obtained, which occurs in a temperature window between 32 and 39 degrees C, as indicated in the PFG data by an anomalous temperature dependence of the diffusion coefficient and in the relaxation data by a bi-exponential magnetization decay. The phase separation temperature of the mixture in the pore is slightly lower than in the bulk mixture of the same composition (41 degrees C) and extends over a finite temperature range. A qualitative model of the phase separation process in the pores is developed, which assumes a temperature-dependent domain-like structure of the liquid below the phase transition temperature and a breakdown of these domains upon reaching the transition temperature.

Journal Article↗

In vivo 1H magnetic resonance spectroscopy of rat brain after valproate administration.

Previous studies have shown that valproate is detectable in vitro by 1H magnetic resonance spectroscopy (MRS) at 1.5 T, whereas in patients on valproate monotherapy, no significant dose-dependent valproate signal could be seen. To investigate whether an increased signal-to-noise ratio as provided by higher valproate doses and increased magnetic field strength would enable detection of valproate in vivo, six Wistar rats were examined using volume-selective 1H MRS at 2.34 T. The spectra were analyzed by fitting a linear superposition of the basis spectra of valproate, brain metabolites, and simulated lipid signals. The analysis revealed no significant signal contributions after valproate administration of up to 330 mg/kg body weight. To analyze how underlying mechanisms, such as potential drug interactions with macromolecules, may affect the valproate signal, additional in vitro spectra of valproate were measured before and after adding albumin. The spectra exhibited a strong decrease of the valproate signal with increasing albumin concentration. The results support the hypothesis that in vivo valproate is bound to a high degree to macromolecules and will therefore not be detectable by 1H MRS.

Animals↗

Navigated diffusion-weighted imaging with interpolated phase-correction for high-resolution imaging of stroke.

Stroke imaging was revolutionised with the introduction of diffusion-weighted MRI (DWI). The commonly used echoplanar DWI suffers from geometrical distortion near the skull base and the frontal regions and from reduced spatial resolution and fat suppression. To allow a voxel-by-voxel comparison between high-resolution spin-echo images, we implemented spin-echo-based DWI. Motion artefacts were eliminated by phase correction in hybrid frequency-Fourier domain using navigator echoes. In a novel approach, distorted navigator echoes which did not eliminate motion artefacts were replaced with interpolated navigator echoes, leading to restored image information. Navigated DWI yielded high-resolution images in 21 of 24 patients with brain ischaemia, allowing diagnosis of even small or diffuse zones of ischaemia. We determined the spatial distribution and mean of T(2)- and DWI signal intensity and apparent diffusion coefficients (ADC), using a multidimensional histogram-based analysis. Mean ADC were decreased in ischaemic areas less than 9 days old. The technique may also be useful for high-resolution DWI of tissue other than the brain.