PubMed Health⌕ Search

Biomedical subjects

E Gornik

Publications and source records attributed to E Gornik.

At least 19 recordsLinked to original sources

Wannier-Stark states in finite superlattices.

Individual Wannier-Stark states are resolved in a current experiment over a wide electric-field range for a 5 and 4 period finite superlattice utilizing a hot-electron transistor. The observed field dependence of the tunneling transmission through the various states directly resembles the progressive localization of the wave functions. The basic transport through Wannier-Stark states in short-period superlattices is identified to be coherent. By tuning the Wannier-Stark state splitting with electric field into the optical phonon energy, the opening of new LO-phonon mediated transport paths is observed.

Journal Article↗

Intersubband transport in quantum wells in strong magnetic fields mediated by single- and two-electron scattering.

We show theoretically that in quantum wells subjected to a strong magnetic field the intersubband current peaks at magnetic field values, which reveal the underlying specific intersubband scattering mechanism. We have designed and grown a superlattice structure in which such current oscillations are clearly visible, and in which the transition from the purely single-electron to the mixed single- and two-electron scattering regimes can be observed by tuning the applied voltage bias. The measurements were conducted in ultrahigh magnetic fields (up to 45 T) to obtain the full spectrum of the current oscillations.

Journal Article↗

Towards functional group-specific detection in high-performance liquid chromatography using mid-infrared quantum cascade lasers.

A distributed feedback quantum cascade laser was applied for the first time as a powerful light source for mid-infrared (MIR) detection in liquid chromatography. Fructose and glucose in red wine were separated with an isocratic HPLC system, which was connected to a custom-made flow cell. This flow cell was constructed of two diamond windows with adjustable spacing and two hollow wave-guides for guiding the incoming and outgoing light. The HPLC column based on an ion-exchange resin with calcium(II) counter ion was run at 80 degrees C with 0.04% formic acid as the mobile phase. Under these conditions the carbohydrates could not be completely separated from the organic acids also present in wine. However, the emission of the laser at 1067 cm(-1) matches the absorption maximum of fructose and glucose, whereas the organic acids do not absorb appreciably at this wavenumber. Thus group-specific detection could be achieved. Additionally, the optical path length could be increased from 25 to 125 microm, which is very promising in gaining enhanced sensitivity compared to Fourier transform IR detection.

Calibration↗

Resonant tunneling mediated by resonant emission of intersubband plasmons.

We study tunneling through resonant tunneling diodes (RTD) with very long emitter drift regions (up to 2 microm). In such diodes, charge accumulation occurs near the double barrier on the emitter side, in a self-induced potential pocket. This leads to a substantial enhancement of the wave function overlap between states of the pocket and the RTD, and, consequently, to increased off-resonant current mediated by various scattering processes. For RTD with the longest drift region (2 microm), an additional strong current peak is observed between the first and the second resonant peaks. We attribute this pronounced feature to the intersubband transitions mediated by resonant emission of intersubband plasmons.

Journal Article↗

A new method of readout in radiochromic film dosimetry.

Radiochromic film as a dosimetry medium offers several advantages in high-resolution radiography. A new technique of readout was developed to measure the optical density distributions of the film in purely directed light. This technique implements radiochromic film dosimetry near the film's absorption maximum by using a single-mode top-surface emitting laser diode (675.2 nm). The effective sensitivity of the film, compared with a helium-neon laser densitometer (632.8 nm), is increased approximately threefold. Good accuracy, high spatial resolution and simple assembly of the readout system is achieved. Beam profiles of the four final collimator helmets of a Leksell Gamma Knife (Elekta Inc., Sweden) were experimentally determined. Measured profiles and full-widths at half maximum are consistent with the computer generated data of the dose planning system (Kula 4.4, Elekta Inc., Sweden). The output factor of the 4 mm collimator (the smallest collimator with the steepest dose gradient), essential for the application of well defined doses, was checked. The measurements established an output factor of 826 +/- 9 that lies 9 +/- 1% lower than the adjusted one.

Calibration↗