PubMed Health⌕ Search

Biomedical subjects

E Higginbotham-Ford

Publications and source records attributed to E Higginbotham-Ford.

3 recordsLinked to original sources

Clinical studies of cancer radioimmunodetection with carcinoembryonic antigen monoclonal antibody fragments labeled with 123I or 99mTc.

Seventy-three patients with diverse cancers containing carcinoembryonic antigen received 123I-labeled anti-carcinoembryonic antigen monoclonal antibody F(ab')2 fragment [38 patients], 99mTc-labeled anti-carcinoembryonic antigen monoclonal antibody Fab' fragment [23 patients], or both reagents at different times [6 patients] for evaluation of antibody targeting and imaging [radioimmunodetection (RAID)], using planar and single-photon emission computed tomography. The results indicated that antibody fragments are preferred for early tumor imaging (within 24 h). Rapid targeting and clearance from blood and normal organs of the antibody fragments (blood median t1/2 elimination of 26.5 and 13.2 h for the F(ab')2 and Fab' fragments respectively) permitted the use of short-lived radionuclides, such as 123I (13.3 h) and 99mTc (6 h), and confirmed that selective antibody accretion in tumors occurred very soon after administration, such as between 2 and 5 h. Scan interpretations at 24 h for the 123I-labeled F(ab')2 and at 2-5 h for the 99mTc-labeled Fab' revealed overall sensitivities, on a tumor site basis, of 95.9 and 94.9%, respectively. On a site basis, the overall accuracies were 94.2 and 93.8% for the 123I and 99mTc immunoconjugates, respectively. In the 6 patients studied with both radioimmunoconjugates, a high concordance in detection was found. Both imaging agents also revealed a high number of putatively new tumor sites not disclosed by other radiological methods at the time of the RAID studies, of which 40.0 and 20.5% were subsequently confirmed as tumor for the 123I and 99mTc agents, respectively, within an 11-month follow-up period. This represented 24 proven occult tumor sites in 19 patients given the 123I-immunoconjugate and 16 proven occult tumor sites in 9 patients receiving the 99mTc agent. The new lesions were found up to 17 and 7 months earlier for 123I-RAID and 99mTc-RAID, respectively, than with other detection methods. The smallest tumors identified were below 0.5 cm, especially with the 99mTc immunoconjugate and single-photon emission computed tomography imaging. The findings of this study confirm previous evidence that RAID is a safe and a potentially useful new method of cancer detection. Despite the excellent results with the 123I-F(ab')2 antibody fragment, its poor availability and high cost limit its clinical use. Therefore, the 99mTc agent, which is made by an instant, 1-step, 1-vial, direct labeling method, appears to be the method of choice for rapid and accurate detection of cancer by RAID.

Adolescent↗

Imaging of primary and metastatic liver cancer with 131I monoclonal and polyclonal antibodies against alphafetoprotein.

Thirteen patients with a history of confirmed liver carcinoma were given either I131 goat polyclonal or murine monoclonal antibodies against alpha-fetoprotein (AFP), and then scanned with a gamma camera. In order to reduce background, nontarget activity, especially in the liver, blood pool, and reticuloendothelial system, 99mTc imaging agents were used for tumor image enhancement by computer-assisted subtraction. A sensitivity of 91% for the primary site, 50% for the lungs (33% for the chest area), and 75% for the abdomen and pelvis was achieved, with a specificity of 100%, 94%, and 100% for these sites, respectively. The accuracy was determined to be 93% for the liver, 86% for the lungs (77% for the chest), and 85% for the abdominal and pelvic area, resulting in an overall accuracy rate for imaging primary and metastatic hepatocellular cancer of 84% (90% if bone metastases are excluded). In two of the 13 patients, lesions that had been missed by conventional liver scintigraphy and transmission computed tomography (CT) were first shown by radioimmunodetection (RAID).

Abdominal Neoplasms↗

Human splenic Fc receptor function and dysfunction: definition by circulatory clearance rate compared to computerized kinetic scintigraphy.

In vivo reticuloendothelial Fc receptor function was studied in 14 individuals. To assess this function Tc-99m-labeled IgG-coated autologous erythrocytes were injected intravenously and circulatory clearance rates of radioactivity were determined. In 12 individuals [6 normals and 6 patients with systemic lupus erythematosus (SLE)], kinetic computerized scintigraphic imaging of various internal organs was compared to circulatory clearance rates. Both circulatory clearance rates and percentage splenic uptake (PSU) were significantly depressed in patients. The difference between patients and normals was more significant for PSU than for circulatory clearance. Splenic uptake curves showed significantly less linearity for patients, suggesting that splenic defects in SLE are not only quantitative, but also are qualitative. Understanding the nature of immune clearance defects in immune complex mediated diseases may allow for a more rational approach to treatment of patients with these disorders.

Adult↗