Changes in long-bone structural properties during the first 8 weeks of plate implantation.

The midplate structural rigidities of metal- and plastic-plated intact canine femora were experimentally determined after initial plate application and 8 weeks after in vivo implantation. Composite beam theory significantly overestimated the bending rigidities of the metal-plated bones. The rigidities of the plastic-plated bones were nearly identical to that of the isolated bone, as composite beam theory predicted. Plating with either plate increased the intracortical porosity and caused the deposition of periosteal new bone, which was greater with plastic than with metal plates. The increased rigidities provided by the attachment of the metal plates and, hence, the degree of bone strain shielding were variable. Platings for 8 weeks which provided little strain shielding with either metal or plastic plates caused an increase in bone flexural rigidity (measured after plate removal) with respect to the contralateral control. Platings that provided increasing amounts of strain shielding caused a decreasing midplate bone rigidity (measured after plate removal) and increasing bone deposition at the outer screws. These findings suggest that the surgical implantation of any plate (metal or plastic) will provide a net stimulus to bone formation and consequently increased bone structural rigidity, even though intracortical porosity is increased. If the plate significantly reduces the normal loads borne by the bone, however, there is a net stimulus to remove bone, resulting in a loss of midplate structural rigidity within 8 weeks of implantation.

Animals↗

Comparative fatigue behavior of different bone cements.

Tensile and fatigue studies were performed on four different preparations of acrylic bone cement: (1) surgical Simplex-P inserted into molds in the dough stage, (2) Zimmer Low Viscosity Cement (LVC) inserted in the liquid phase, (3) an experimental cement inserted in the dough phase, and (4) the same experimental cement inserted in the liquid phase. The void characteristics of the cements appeared to dictate their mechanical performance. While tests revealed no difference in the tensile strengths of the four cement preparations, small but statistically significant differences in mean fatigue life were observed. The experimental cement used in the dough stage exhibited superior fatigue characteristics when compared with Simplex and LVC. LVC had the poorest mechanical properties of the four cement groups. Since the specimen preparation procedures can markedly influence the cement void characteristics and, consequently, the mechanical properties, general statements about different cement types are offered with considerable reservations.

Bone Cements↗

Centrifugation as a method of improving tensile and fatigue properties of acrylic bone cement.

In this study centrifugation dramatically reduced the porosity and substantially increased the mechanical properties of bone cement. Monotonic tensile tests to failure of centrifuged specimens of cement demonstrated an increase of 24 per cent in the mean ultimate tensile strength compared with the control value. Mean ultimate tensile strain was improved by 54 per cent. In fully reversed tension-compression fatigue-testing, centrifugation resulted in a mean increase in fatigue life of 136 per cent. These strong advantages in mechanical properties were obtained without any detrimental changes. There was no change in elastic modulus, setting time, or peak temperature. Handling properties were improved. There was no increase in systemic toxicity as demonstrated in dogs by assessment of arterial blood-pressure response and peak levels of monomer in the serum during simulated total hip arthroplasty. We also present a practical system of cement centrifugation and delivery that is suitable for use in the operating room.

Acrylic Resins↗

Tensile fatigue failure of acrylic bone cement.

Tensile fatigue tests of acrylic bone cement were conducted under strain control in a wet environment at 37 degrees C. A constant strain rate of 0.02s-1 was used, resulting in physiologic loading frequencies. Comparison of the tensile fatigue data with the results of previous tension-compression fatigue tests indicates that fatigue failure is governed primarily by the maximum cyclic tensile strain. The compressive portion of the loading cycle has little effect on the number of cycles to failure. A new empirically derived equation is introduced to describe the influence of mean strain and strain amplitude on fatigue endurance. The results emphasize the critical role tensile strains may play in cement failure and loosening of total joint replacements.

Bone Cements↗

Strain-controlled fatigue of acrylic bone cement.

Monotonic tensile tests and tension-compression fatigue tests were conducted of wet acrylic bone cement specimens at 37 degrees C. All testing was conducted in strain control at a strain rate of 0.02/s. Weibull analysis of the tensile tests indicated that monotonic fracture was governed more strongly by strain than stress. The number of cycles to fatigue failure was also more strongly controlled by strain amplitude than stress amplitude. Specimen porosity distribution played a major role in determining the tensile and fatigue strengths. The degree of data scatter suggests that Weibull analysis of fatigue data may be useful in developing design criteria for the surgical use of bone cement.

Acrylic Resins↗