Virtual endoscopy of the labyrinth, using a 3D-FastASE sequence.

Virtual endoscopy (VE) of the labyrinth was performed using three-dimensional (3D)-fast asymmetric spin-echo MR imaging. The spatial resolution requirements and the usefulness of zero-fill interpolation (ZIP) were evaluated, and VE was used to examine three patients. The (0.6-mm) voxel data with ZIP satisfies the minimum requirements for VE for evaluation of the complex 3D anatomy and pathology of the labyrinth. J. Magn. Reson. Imaging 2001;13:792-796.

Adolescent↗

Water fat separation using the single acquisition "sandwich" type 3-point Dixon method to optimize knee joint scans.

In this paper, we tried to evaluate the effect of water-fat separation on and to optimize the scan condition of the newly developed "Sandwiched" 3-point Dixon method at 0.35 Tesla (T), for knee joint imaging. Using a 0.35T superconductive open magnet system with a solenoid type knee coil, one male and two female normal volunteers (27-37 y.o.) underwent knee joint imaging. Each sequence provided good water-fat separated images. At 0.35T, the gradient echo provided a better contrast than the spin echo. Optimal cartilage-marrow and cartilage-fluid contrast could be obtained at a frip angle (FA) of 90 degrees. There was no significant correlation between cartilage-marrow, cartilage-fluid contrast and repetition time (TR) values within the tested range. Cartilage-fluid and cartilage-marrow contrast were both best at an FA of 90 degrees with the gradient echo sequence. TR from 350 ms to 650 ms did not cause any significant contrast difference in the fat suppressed images. This method is useful and could be the only practical choice for obtaining fat suppressed T1 weighted images for joint magnetic resonance (MR) imaging at 0.35T.

Adipose Tissue↗

MR imaging of the enlarged endolymphatic duct and sac syndrome by use of a 3D fast asymmetric spin-echo sequence: volume and signal-intensity measurement of the endolymphatic duct and sac and area measurement of the cochlear modiolus.

BACKGROUND AND PURPOSE: In enlarged endolymphatic duct (EED) and sac (EES) syndrome, deformity of the EED and EES is congenital; however, hearing loss is acquired. To investigate the pathophysiology of progressive sensorineural hearing loss in EED and EES syndrome, we measured the volume of the EED and EES, the diameter of the EED and EES, the area of the cochlear modiolus, and the signal intensity of the EES and compared our findings against degree of hearing loss. METHODS: Thin-section MR images of 33 ears in 17 patients with EED and EES syndrome were studied. All studies were obtained on a 1.5-T MR unit using a quadrature surface phased-array coil. Heavily T2-weighted 3D fast asymmetric spin-echo images were obtained with a voxel size of 0.3 x 0.3 x 0.8 mm without zero-fill interpolation. Two radiologists traced the areas of the EED and EES manually, and the volume was calculated. The area of the cochlear modiolus, diameter of the EED and EES, and signal intensity of the EES were also measured by drawing regions of interest manually. The signal intensity ratio of EES/CSF was calculated. These measured values were compared against audiographic data, and the degree of linear correlation was determined. RESULTS: The volume of the EED and EES, the area of the modiolus, the diameter of the EED and EES, and the signal intensity of the EES did not show significant correlation with degree of hearing loss. CONCLUSION: These findings suggest that there is a microscopic area of damage or fragility in the inner ear not visible even with thin-section heavily T2-weighted MR imaging.

Adolescent↗

Magnitude subtraction vs. complex subtraction in dynamic contrast-enhanced 3D-MR angiography: basic experiments and clinical evaluation.

Magnitude subtraction and complex subtraction in dynamic contrast-enhanced three-dimensional magnetic resonance (3D-MR) angiography were compared using a phantom and 23 human subjects. In phantom studies, complex subtraction showed far better performance than magnitude subtraction, especially for longer echo times, with thicker slices, and without fat suppression. With complex subtraction, non-fat-suppressed studies showed contrast-to-noise ratios comparable to those in fat-suppressed studies. In human subjects, complex subtraction was superior to magnitude subtraction in 9 subjects, but comparable to magnitude subtraction in 14 subjects. There were no cases in which magnitude subtraction was superior to complex subtraction. Although the differences observed in human studies when complex subtraction was applied with thinner slices, shorter echo times, and the fat-suppression technique were not as pronounced as those seen in phantom studies, complex subtraction should be performed in dynamic contrast-enhanced 3D-MR angiography because there are no drawbacks in complex subtraction. Further research is necessary to assess the feasibility of dynamic contrast-enhanced 3D-MR angiography without fat suppression in human subjects using complex subtraction, as suggested by the results of phantom studies. If it is found to be feasible, dynamic contrast-enhanced 3D-MR angiography without fat suppression using complex subtraction may prove to be a robust technique that eliminates the need for shimming and can reduce the acquisition time. J. Magn. Reson. Imaging 1999;10:813-820.

Adult↗

MR imaging of the cochlear modiolus: area measurement in healthy subjects and in patients with a large endolymphatic duct and sac.

PURPOSE: To evaluate the cochlear modiolus with thin-section magnetic resonance (MR) imaging in healthy subjects and patients with a large endolymphatic duct and sac, and to assess whether the cochlea is normal or abnormal in patients with a large endolymphatic duct and sac. MATERIALS AND METHODS: MR images were obtained in 10 ears in five volunteers (group 1), 40 ears in 20 patients with bilateral sensory hearing loss (group 2), three ears in two patients with Mondini malformation (group 3), and 12 ears in seven patients with a large endolymphatic duct and sac (group 4). RESULTS: In groups 1 and 2, all modiolar areas were larger than 4.0 mm2. In group 3, each modiolus was smaller than 2.0 mm2. In group 4, modiolar areas were smaller than 2.0 mm2 in eight ears and were larger than 4.0 mm2 in four ears. CONCLUSION: Findings in this study confirm that a large endolymphatic duct and sac is frequently associated with modiolar deficiency, but the modiolar area is normal in some cases. This result does not support the recently proposed hypothesis that hearing loss with a large endolymphatic duct and sac is caused by the transmission of subarachnoid pressure forces into the labyrinth through a deficient modiolus.

Adolescent↗

High-resolution MR cisternography of the cerebellopontine angle: 2D versus 3D fast spin-echo sequences.

BACKGROUND AND PURPOSE: The clinical usefulness of MR cisternography of the cerebellopontine angle, applying 2D or 3D fast spin-echo sequences, has been reported recently. Our purpose was to investigate the cause of signal loss in CSF in the prepontine or cerebellopontine angle cistern on 2D FSE MR images and to compare the cisternographic effects of 2D and 3D FSE sequences. METHODS: Preliminary experiments were performed in four volunteers to assess the causes of signal loss. Initially, using a 2D cardiac-gated cine phase-contrast method with a velocity encoding value of 6 cm/s, we measured the velocity and flow pattern of CSF. Comparisons were made to assess the effects of intravoxel dephasing, amplitude of the section-selecting gradient, echo time (TE), and section thickness. Four healthy subjects and 13 patients with ear symptoms were examined, and multisection 3-mm-thick 2D images and 30-mm-slab, 1-mm-section 3D images were compared qualitatively and quantitatively. Then, 3D MR cisternography was performed in 400 patients with ear symptoms, and qualitative evaluation was performed. RESULTS: In volunteers, the average peak velocity of CSF was 1.2 cm/s. With TE = 250, CSF may move an average of 3 mm, and can be washed out of a 3-mm-thick 2D section volume. The CSF signal relative to that of a water phantom decreased gradually as TE increased on single-section 3-mm-thick 2D images. The CSF signal relative to that of the water phantom increased gradually as section thickness increased. No significant differences were noted in intravoxel dephasing and amplitude of the section-selecting gradient. The contrast-to-noise ratio (CNR) between CSF and the cerebellar peduncle, and the visibility of the cranial nerves and vertebrobasilar artery were significantly improved on 3D images in 17 subjects. In images from 400 patients, no significant signal loss in the cistern was observed using 3D FSE. CONCLUSION: CSF signal loss in thin-section 2D MR cisternography is mainly attributable to the wash-out phenomenon. 3D acquisition can reduce this phenomenon and provide thinner sections. The scan time for 3D acquisition is not excessive when a long echo train length and half-Fourier imaging are used. MR cisternography should be performed using a 3D acquisition.

Cerebellopontine Angle↗

High-resolution MR cisternography of the cerebellopontine angle, obtained with a three-dimensional fast asymmetric spin-echo sequence in a 0.35-T open MR imaging unit.

High-resolution MR cisternography performed with 3D fast asymmetric spin-echo imaging (3D fast spin-echo with an ultra-long echo train length and asymmetric Fourier imaging) was optimized in a 0.35-T open MR imaging unit. The 0.35- and 1.5-T images of the two volunteers and three patients with acoustic schwannomas were then compared. The optimal parameters for images obtained by 3D fast asymmetric spin-echo imaging at 0.35 T were as follows: field of view, 15 cm; matrix, 256 x 256 x 40; section thickness, 1 mm; echo train length, 76; and imaging time, 10 minutes 44 seconds. Scans obtained from both normal volunteers showed the facial, cochlear, and superior and inferior vestibular nerves separately in the internal auditory canal on both 0.35- and 1.5-T images. All three acoustic schwannomas were depicted on both 0.35- and 1.5-T images. Screening for disease at the cerebellopontine angle and in the internal auditory canal, without the administration of contrast material on a low-field open MR imaging unit and within a clinically acceptable imaging time, may be possible. Further controlled prospective studies are required, however, before implementation on a wide basis. If proved effective, this may be of particular value for reducing healthcare costs and for imaging claustrophobic and pediatric patients in an open system.

Cerebellopontine Angle↗