PubMed Health⌕ Search

Biomedical subjects

E J Adam

Publications and source records attributed to E J Adam.

39 records · Page 3Linked to original sources

Patterns of breast skin thickness In normal mammograms.

Measurement of the mammographic skin thickness over different parts of the breast was performed in 150 normal patients. The patients were divided into three groups based on breast size and the skin thickness in these three groups compared. The results showed that skin thickness decreased with increasing breast size and that the upper limit of normal was greater than the previously quoted normal range at 3.0 mm. Measurement over different parts of the breast showed that medial exceeded lateral skin thickness by up to 100%, and similarly for the inferior and superior measurements. These findings in the normal breast are of importance in deciding on the presence or absence of abnormal skin thickening as an indicator of underlying breast disease.

Adult↗

CT monitoring of therapy for meconium ileus.

Meconium ileus equivalent is a common complication of cystic fibrosis in the postneonatal period. Because of the added risks of surgery in these patients, conservative management is preferred. We describe here a method of monitoring the conservative treatment of this condition using CT and suggest that its application will reduce the need for potentially dangerous surgical intervention.

Adolescent↗