PubMed Health⌕ Search

Biomedical subjects

E J Boote

Publications and source records attributed to E J Boote.

9 recordsLinked to original sources

Longitudinal assessment of intra-abdominal fat in postmenopausal women.

Longitudinal changes in intra-abdominal (IA) fat and total body fat were assessed in three healthy postmenopausal Caucasian women receiving hormone replacement therapy (HRT) during a seven-year follow-up study. Measurements were made using dual-energy X-ray absorptiometry, anthropometry, and magnetic resonance images. Changes in intra-abdominal fat were examined in relation to different patterns of weight modification. The weight-stable women had the lowest percent body fat and IA fat at all examinations, with a slight decrease in IA fat at follow-up. The person with a gradual gain in weight of 1.9 kg experienced small increases in body fat and IA fat. The weight-cycling woman had the highest weight, percent body fat, and IA fat area at all examinations. The amounts of IA fat and percent body fat fluctuated with body weight fluctuations. Together with other findings, our results suggest that lean, weight-stable individuals receiving HRT can maintain a low level of IA fat, whereas those experiencing weight gains or regaining lost weight have increases in IA fat.

Abdomen↗

Anthropomorphic 1H MRS head phantom.

An anthropomorphic 1H MRS head phantom has been developed which mimics the in vivo structure, metabolite concentrations, and relaxation times (for both water and metabolites) of human brain tissue. Different brain regions and two tumor types, fluid-containing ventricles, and air-filled sinus, and subcutaneous fat are all simulated. The main tissue-mimicking materials are gelatin/agar mixtures with metabolites and several other ingredients added. Their composition and method of production are thoroughly described. T1's and T2's of water in the phantom are very close to in vivo values, and metabolite T1's and T2's are considerably more realistic than those in aqueous solutions. Spectra and relaxation times for the pig brain were also acquired and compare well with those of the phantom. The realistic properties of this phantom should be useful for testing spectral quantitation and localization.

Animals↗

Computer-assisted instruction: MR imaging of the knee.

Computer-assisted education offers a unique method of learning that is complementary to conventional learning techniques. The regional anatomy of musculoskeletal magnetic resonance (MR) imaging lends itself well to discrete learning modules on the computer. This article describes a computer-assisted educational program for MR imaging of the knee. The program is divided into four sections: MR imaging physics, anatomy, pathology, and a quiz. The program has cross-references between the sections that allow comparison of normal versus pathologic findings, review of specified pathologic entities, and self-testing of comprehension. The student can progress through the program in a linear or nonlinear fashion at his or her own pace. All images in the program were digitally acquired with an MR imager and transferred directly to the computer used to develop the program. The program is available throughout the radiology department on a local area network and in the medical school library on stand-alone units. The program is currently being used at a medical school as a supplement to the recently implemented problem-based learning curriculum and for resident education.

Computer-Assisted Instruction↗

Improved resolution backscatter coefficient imaging.

This paper reports the extension of a method for imaging acoustic backscatter coefficients that allows for greater spatial resolution in the resulting images. This is done by using a broad-band excitation pulse and short-duration time gates in the analysis. The images produced had better spatial resolution than the previously reported technique [Ultrasonic Imaging 10, 121-138]. Furthermore, the pixel values were based upon quantitatively accurate backscatter coefficients at given spatial locations. The paper also discusses the additional computational requirements of greater spatial resolution and proposes a least-squares fit to a smoothly varying set of sparse data to generate the data points in between.

Ultrasonics↗

Accurate depth-independent determination of acoustic backscatter coefficients with focused transducers.

The accuracy of a method of data reduction for determining acoustic backscatter coefficients was tested using focused transducers and narrow-band pulses. Two phantoms with well-defined scattering properties were the bases of the tests, one having low attenuation and one with tissue-mimicking attenuation. The experimentally determined backscatter coefficients were found to be independent of transducer-to-scattering-volume distance and to agree very well with theoretical values, typically within 10%.

Acoustic Stimulation↗

Instrument-independent acoustic backscatter coefficient imaging.

This paper presents an adaptation of a method for determining acoustic backscatter coefficients to produce quantitative ultrasound images. Backscattered echo signals are recorded from a region to be imaged and backscatter coefficients are determined and related to spatial position. The values of the backscatter coefficients are then translated into a gray scale image. Testing of this imaging technique has been performed using tissue-mimicking phantoms which contain sections having backscatter coefficients different from that of the surrounding material. The technique has also been tested using a phantom in which a fat-mimicking layer is interposed between the acoustic window and the main body of the phantom. The images produced were found to be quantitatively accurate throughout the phantom, including the sections with differing backscatter. Quantitative accuracy did not suffer when the fat-mimicking layer was present.

Models, Structural↗

Performance tests of Doppler ultrasound equipment with a tissue and blood-mimicking phantom.

A tissue- and blood-mimicking phantom was assembled for assessing the performance of ultrasound Doppler equipment. The phantom is in the shape of a rectangular parallelepiped with a 10 x 20 cm scanning window and a depth of 16 cm. Components of the phantom include a tissue-mimicking material, 7.9 mm diameter simulated vessels, a fluid with similar back-scatter as whole blood, and a peristaltic pumping system producing peak scatterer velocities greater than 1 m/sec. Performance tests done with the phantom are outlined. These include assessments of the maximum depth of penetration and of the directional discrimination capabilities of the instrument, determinations of the accuracy of displayed flow velocities, and accuracy assessments of the displayed position of the Doppler sample volume.

Blood Flow Velocity↗

Backscatter coefficient imaging using a clinical scanner.

A clinical ultrasound scanner has been integrated with a digital data acquisition system to record echo signals for off-line processing of quantitative acoustic backscatter images. The method used to determine backscatter coefficients accounts for experimental factors related to the beam directivity function, the transmitting and receiving electronics, and the attenuation path of the beam. After characterization and calibration of the ultrasound scanner according to the data processing requirements, the quantitative backscatter coefficient for tissue-mimicking phantoms are within 14% of a value predicted by scattering theory. On five normal volunteers, preliminary in vivo liver images of the acoustic backscatter coefficient are obtained. Results from this study are compared to previously published in vitro results.

Humans↗