PubMed Health⌕ Search

Biomedical subjects

E J Dabezies

Publications and source records attributed to E J Dabezies.

At least 19 recordsLinked to original sources

Magnetic resonance imaging of the interosseous membrane of the forearm.

BACKGROUND: Diagnosis of damage to the interosseous membrane of the forearm after trauma is difficult. Patients with a proximal radial fracture and associated damage to the interosseous membrane may have wrist pain in association with subluxation or dislocation of the distal radioulnar joint. Accurate identification of injury to the interosseous membrane may allow better planning of surgical treatment. METHODS: T1 and T2-weighted magnetic resonance images that were made in the axial, sagittal, and coronal planes were used to evaluate the interosseous membrane in the forearms of cadavera, volunteers, and patients. The images were evaluated subjectively by two orthopaedic surgeons and a musculoskeletal radiologist. RESULTS: The interosseous membrane was most consistently visualized on the axial images. Axial T2-weighted images showed the interosseous membrane clearly. The addition of fat-suppression techniques allowed abnormalities to be identified more accurately. Fast-spin-echo techniques were used to obtain data quickly and accurately. CONCLUSIONS: The intact and disrupted interosseous membrane can be evaluated with use of magnetic resonance imaging. Axial T2-weighted fast-spin-echo images with fat suppression in the middle one-third of the forearm provide the most accurate information.

Forearm↗

Ganglions of the proximal interphalangeal joint.

Ganglions of the proximal interphalangeal joint are uncommon. Six patients (nine ganglions) were treated surgically. The lesions presented on the ulnar aspect of the extensor mechanism between the lateral band and the central slip and communicated with the joint by means of a stalk. Mild degenerative joint disease was noted in each case. Surgical excision provided relief of symptoms, and no patient has experienced any recurrence to date.

Adult↗

Tissue expansion prior to revision total knee arthroplasty.

The first case of the use of a tissue expander in revision total knee surgery is reported. A 76-year-old woman presented with extremely adherent scare tissue on the anterior proximal tibia that was the result of multiple debridements and skin grafting for an infected primary total knee arthroplasty. The tissue expander was placed prior to subsequent revision total knee arthroplasty to permit complete excision of the scar and to provide tension-free closure with normal skin at the time of revision. Three years after the surgery, the patient is doing well.

Aged↗

Fractures in very low birth weight infants with rickets.

A syndrome in very low birth weight premature infants weighing less than 1500 g is evidenced by developmental nutritional rickets and fractures at 75 days of age. In a review conducted over 42 months, 247 very low birth weight cases were identified. Rickets was diagnosed in 96 (39%) infants whose mean age was 50 days and fractures were diagnosed in 26 (10.5%) infants whose mean age was 75 days. These 26 infants experienced 98 fractures: 10 humerus, 13 radius, 8 ulna, 4 metacarpal, 3 clavicle, 54 ribs, 5 femur, and 1 fibula. Risk factors included hepatobiliary disease, total parenteral nutrition, diuretic therapy, physical therapy with passive motion, and chest percussion therapy. With early recognition, metabolic therapy and splinting, not casting, are appropriate treatments.

Diuretics↗

Femoral osteotomy for secondary arthritis of the hip in young adults.

Osteotomy around the hip is a valuable and important treatment option in hip disease. It may be used on either side of the joint or in a combined fashion. The authors review the scientific background to femoral osteotomy and summarize its role in the treatment of developmental dysplasia, nonunion of femoral neck fractures, osteonecrosis, slipped capital femoral epiphysis and Perthes disease. They conclude that it is a most useful tool for the contemporary hip surgeon. The procedure may not be appropriate for elderly patients with arthritic deterioration of the hip, but in carefully selected young adults with clearly defined antecedent developmental conditions, the results can be excellent and long lasting. Careful preoperative planning is emphasized; particular attention must be paid to the possibility of arthroplasty in the future because insertion of the stem of a hip prosthesis can be a problem difficult.

Age Factors↗

Enhanced spino-pelvic fixation for segmental spinal instrumentation: a preliminary biomechanical evaluation.

A new method for spino-pelvic fixation of Luque rods was developed and biomechanically evaluated on cadaveric specimens. The technique is surgically simpler and faster than the Galveston technique because it does not require the complex three-dimensional bending of rods to conform to the medullary cavity of the iliac wings. Spines were tested in axial compression in both bilateral and unilateral ischial weight bearing in the intact condition, instrumented with the new technique, and instrumented with the Galveston technique. Compared to the intact spine, the technique increased bilateral average stiffness by 131% and unilateral average stiffness by 192%. Compared directly to the Galveston technique, the new method exhibited increased average stiffness of 15% in bilateral and 11% in unilateral ischial weight bearing. The new method combines the advantages of a simpler and faster surgical procedure than the Galveston technique with enhanced spino-pelvic fixation with the potential to decrease migration of rods relative to each other and the pelvis.

Aged↗

Interlocking intramedullary fixation of hand fractures.

Reduction and stabilization can be especially difficult in treating comminuted hand fractures with bone loss or nonunion. Two cases are presented to illustrate a method of intramedullary fixation using an AO mini fragment reconstruction plate, which allows interlocking fixation proximally and distally. Any defect can be filled with corticocancellous bone graft. When necessary, this graft can be fixed to the metal plate that acts as a strut. The fixation obtained is stable against rotational, angular, and compressive forces, making it a useful adjunct to the hand surgeon's armamentarium.

Adolescent↗

Plate fixation of the humeral shaft for acute fractures, with and without radial nerve injuries.

We report herein the results of operatively treating 44 consecutive acute fractures of the humeral shaft using plates for internal fixation. Ninety-seven percent (43 of 44) of the fractures healed after plate fixation at an average of 12 weeks. One short plate pulled out and required revision with a longer plate and bone grafting; this fracture also healed. Cancellous bone grafting successfully filled in cortical bone gaps. Range of motion of the shoulder and elbow were essentially normal. Plate size varied depending on the location of the fracture and bone size. Eight of nine fractures treated with 3.5-mm compression plates healed uneventfully. All 11 open fractures, eight from bullet wounds, healed uneventfully after early plating. Fifteen radial nerve injuries were associated with the fractures. Twelve anatomically intact radial nerve palsies recovered in 17 weeks on average after plate fixation. One lacerated nerve was sutured and recovered. One nerve with segmental loss associated with an open fracture was left unrepaired, as was an avulsed nerve associated with a closed fracture. The dissection required for plate fixation provides information that may be helpful in determining appropriate treatment of radial nerve injuries and the prognosis for spontaneous return of function.

Adolescent↗

Anatomical demonstration of the nerve-supply to the flexor tendon.

A dissection of four unembalmed human fingers demonstrated a branch from the digital nerve which enters the flexor tendon sheath at the same place as the transverse branch of the digital artery. We conclude that this branch supplies the nerve fibres found within the vinculum.

Cadaver↗

The small pin circular fixator for proximal tibial fractures with soft tissue compromise.

We used a Monticelli-Spinelli small pin circular external fixator in five cases, in combination with closed reduction or limited open reduction internal fixation, to salvage a satisfactory result in juxtaarticular, intraarticular fractures of the proximal tibia, when associated soft tissue compromise prevented standard fixation with plates and screws. The small pin circular fixator allows juxtaarticular placement of the small pins, enhancing stabilization of the comminuted fractures, allowing early range of motion of the joint and early patient mobilization. The small diameter pins support the soft cancellous bone fragments. This technique attempts to combine the benefits of traction, external fixation, and limited internal fixation. We recommend this method as a salvage procedure when plates and screws are contraindicated because of poor bone and soft tissue conditions.

Adult↗

The small pin circular fixator for distal tibial pilon fractures with soft tissue compromise.

A Monticelli-Spinelli small pin circular external fixator was used in combination with closed reduction or a limited open reduction internal fixation in five cases in an attempt to salvage a satisfactory result in distal tibia pilon fractures when associated soft tissue compromise prevented standard fixation with plates and screws. The small pin fixator enhances the ability to perform a closed reduction through a technique that uses distraction with pins in the tibia and calcaneus, combined with correction of angulation by tensioning wires with a stop nut. Small pin stabilization of these comminuted fractures allows early patient mobilization. The small diameter pins support the soft cancellous bone fragments. This technique attempts to combine the benefits of traction, external fixation, and limited internal fixation. We recommend this technique as a salvage procedure when plates and screws are contraindicated because of poor bone and soft tissue conditions.

Adult↗

Intracapsular hip fractures: case reports and discussion.

Two cases of intracapsular hip fracture illustrate some of the treatment options available for Garden Stage IV fractures. In Case 1, a prosthesis was chosen because of the patient's physiologic age and poor general health. In Case 2, a compression screw augmented with a single-pin fixation to prevent rotation was used. This patient, although only 3 years younger than the first patient, was in good health. Although there was some posterior comminution, an attempt at fixation, allowing time for bone healing, was appropriate. Arthroplasty may be needed in several years if bone healing fails.

Female↗

Measurement of effective pedicle diameter in the human spine.

Effective pedicle diameter (EPD), the maximal cancellous diameter of the spinal pedicle, demonstrates the maximal diameter available for transpedicular screw placement. The pedicles of 16 spines from T6 to L5 were measured directly with a graduated mean increase in the EPD ranging from 4.8 mm at T6 to 5.9 mm at L5. This direct pedicle measurement was significantly smaller than that of previously reported studies, which directly and radiographically measured pedicle outside width rather than inner diameter. Three specimens had little, if any, pedicular medullary cavity on direct measurement, although radiographic appearance of a medullary cavity existed. If EPD is significantly smaller than radiographic pedicle width measurements, safe transpedicular screw fixation may not be achieved. Preoperative planning must account for this so that transpedicular screws of correct diameter may be used and the complications of pedicular blowout fracture and neurologic impairment may be avoided.

Adult↗

Stabilization of sacroiliac joint disruption with threaded compression rods.

Eleven cases of sacroiliac dislocation and/or fracture (Malgaigne pattern) were successfully reduced and stabilized using two threaded compression rods. The mean follow-up period was 26.1 months (range, seven to 45 months). None of the implants failed and there was no subsequent displacement. Two patients had mild residual lower back pain, and one was treated with implant removal without subsequent relief of pain. One patient, in whom the operation was done 110 days after dislocation, had extension of an incomplete preoperative peroneal nerve palsy. After anterior pelvic ring stabilization has been performed, two threaded 3/16-inch diameter rods are driven from the normal posterior iliac wing superficial to the sacrum and through the reduced opposite iliac wing. Compression is obtained with washers and nuts. This procedure can be performed safely and effectively, providing stable fixation and allowing early mobilization to help lessen or prevent the complications associated with prolonged bed rest.

Adolescent↗

Complex femur fractures: treatment with the Wagner external fixation device or the Grosse-Kempf interlocking nail.

One hundred complex femur fractures were treated with the Grosse-Kempf interlocking nail and 35 were treated with the Wagner external fixation device. Retrospectively, we analyzed the results in the two groups to determine specific indications for the future use of these nails. The Grosse-Kempf nail, although a technically demanding procedure, achieved excellent overall end results in comminuted closed fractures, and in Type I, Type II, and some Type III open fractures after appropriate wound care. We found that the Wagner apparatus was a simple, easy device for obtaining initial fracture stabilization in contaminated Type III-B and Type III-C open fractures. It does, however, require substantial postoperative care; four cases required secondary intramedullary fixation. We found a high infection rate with secondary reamed intramedullary nailing after initial stabilization with the external fixator.

Adolescent↗