PubMed Health⌕ Search

Biomedical subjects

E J Rasmussen

Publications and source records attributed to E J Rasmussen.

3 recordsLinked to original sources

Alternative prosthodontic technique for tissue-integrated prostheses.

This modified technique for fabrication of tissue-integrated prostheses saves valuable clinical time for the dentist and treatment time for the patient. The technique differs in that a modified denture is placed in the mouth the day of the second operation, impression copings are eliminated at the final impression, the framework is fabricated before jaw relation records, a high-content palladium alloy is used for the framework, the master cast is flasked similar to a complete denture technique, and the access openings are closed with a light-cured resin. Prerequisites for a tissue-integrated prosthesis are not violated and comparable results are achieved. The technique can also be used in maxillary arches and, with slight modifications, for partially edentulous patients. This technique has been used 3 years for 35 jaws in 37 patients, with 184 fixtures. Four fixtures have failed, producing a 98% success rate. All prostheses have remained continuously stable. Economy of clinical time and laboratory procedures in the prosthodontic phase increase the acceptance of osseointegration in clinical dentistry. The cooperative efforts of all disciplines will provide a greater acceptance of this treatment modality, which will enhance the patients' quality of life.

Dental Alloys↗

An investigation of tensile strength of dental solder joints.

Tensile specimens of dental solder joints were tested to determine the effect of gap distance on the strength of solder joints. Two dental alloys were used; a Type III gold alloy and a gold-palladium (Au-Pd) alloy. The Type III alloy was joined with the recommended gold solder. The Au-Pd alloy was joined using preceramic and postceramic application soldering techniques. Gap distances of 0.13 mm, 0.5 mm, and 1 mm were used with each soldering technique. All solder specimens were machined to a uniform diameter and then tested for tensile strength. It was concluded that: 1. There was a significant increase in strength for the Type III gold as the gap distance was increased. 2. The trend toward stronger joints at narrow gap distances for Au-Pd alloy joined with presolder was not statistically significant. 3. The trend toward stronger joints at wide gap distances for the Au-Pd alloy joined with the postsolder was not statistically significant. 4. The postsolder joints were statistically stronger than the presolder joints. 5. The trends observed could be partially explained in terms of competing effects of yield strength (triaxially), wettability, and void or inclusion content at the various gap distances.

Dental Alloys↗