Accurate mass measurements using MALDI-TOF with delayed extraction.

Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry is now an essential tool in biopolymer analysis. Sensitivity and mass range are unsurpassed, but mass measurement accuracy and resolution have been limited. With delayed extraction and a reflecting analyzer, mass measurements using MALDI-TOF can be made with an accuracy of a few parts per million (ppm). It is possible to distinguish Lys from Gln in peptides, and to determine the elemental composition of smaller molecules (mass 100-500). In database searching strategies, a smaller mass window, resulting from an increase in mass accuracy, greatly decreases the number of possible candidates. Mass measurement accuracy with errors less than 5 ppm is demonstrated on a mixture of 12 peptides ranging in mass from ca. 900 to 3700 Da. Mass measurements on 13 peaks in an unseparated tryptic digest of myoglobin gave results with an overall average error less than 3.5 ppm, with a maximum error of 7 ppm.

Adrenocorticotropic Hormone↗

Sequencing oligonucleotides by exonuclease digestion and delayed extraction matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

A protocol was developed for sequencing oligonucleotides by matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry. Oligonucleotides were partially hydrolyzed in separate time-course digestions with 3' --> 5' and 5' --> 3' acting phosphodiesterases in a MALDI-compatible buffer or in the MALDI matrix itself. The partial digests were analyzed by MALDI-TOF mass spectrometry employing an instrument equipped with delayed ion extraction and the sequence was inferred from the mass differences between adjacent peaks. Resolution, mass accuracy, and sensitivity were considerably enhanced with delayed extraction, in comparison with the standard MALDI technique. Much longer lengths of DNA can be unambiguously sequenced with delayed extraction MALDI compared with standard MALDI-MS.

Base Sequence↗

DNA sequencing by delayed extraction-matrix-assisted laser desorption/ionization time of flight mass spectrometry.

Matrix-assisted laser desorption/ionization (MALDI) time of flight mass spectrometry was used to detect and order DNA fragments generated by Sanger dideoxy cycle sequencing. This was accomplished by improving the sensitivity and resolution of the MALDI method using a delayed ion extraction technique (DE-MALDI). The cycle sequencing chemistry was optimized to produce as much as 100 fmol of each specific dideoxy terminated fragment, generated from extension of a 13-base primer annealed on 40- and 50-base templates. Analysis of the resultant sequencing mixture by DE-MALDI identified the appropriate termination products. The technique provides a new non-gel-based method to sequence DNA which may ultimately have considerable speed advantages over traditional methodologies.

Base Sequence↗