PubMed Health⌕ Search

Biomedical subjects

E J Wiesen

Publications and source records attributed to E J Wiesen.

8 recordsLinked to original sources

Generation of parametric images during routine Tc-99m PYP inhalation/Tc-99m MAA perfusion lung scintigraphy. Technical note.

A simple technique is described for generating ventilation/perfusion ratio and perfusion/ventilation ratio images from the posterior Tc-99m PYP aerosol inhalation and Tc-99m MAA perfusion images obtained during routine lung scintigraphy. These images highlight areas of ventilation/perfusion incongruence--mismatch or reverse mismatch--that may sometimes be difficult to detect on conventional images.

Aerosols↗

Improvement in CT pelvimetry.

When computed tomographic (CT) digital radiography is used for pelvimetry, measurement error may occur. Geometric distortion in the lateral direction of the CT digital radiograph can lead to an error in any measurement of the transverse pelvic inlet. The authors measured the magnitude of this error on two scanners and present a general method for correction of this potential error. The authors also showed that an additional dose reduction is possible if the patient is imaged in the posteroanterior rather than anteroposterior projection.

Female↗

Paranasal sinuses: low-dose CT.

While computed tomography (CT) has become an important imaging modality in the evaluation of the paranasal sinuses, the radiation dose remains higher than is necessary. With use of a head phantom and constant kilovolt peak setting, axial and coronal CT scans of the paranasal sinuses were obtained at each of six successively lower milliampere second settings than are commonly used in clinical practice. Although noise, as measured by the standard deviation of the CT numbers, did increase, images were of diagnostic quality even when dose levels were reduced by a factor of 28. In the same incremental manner, the milliampere second settings used in scanning 90 patients were reduced, with no loss of diagnostic quality. The authors discuss the methods of analysis and the advantages of use of lower milliampere second settings at CT scanning of the sinuses.

Humans↗

A proposed new mechanism of traumatic aortic rupture: the osseous pinch.

The currently accepted mechanism to explain traumatic aortic rupture from rapid deceleration involves a combination of traction, torsion, and hydrostatic forces. The authors hypothesize that aortic isthmus lacerations result from a pinch of the aorta between the spine and the anterior bony thorax (manubrium, clavicle, and first ribs) during chest compression caused by abrupt deceleration. Compression of an articulated, normally moving thoracic skeleton containing a synthetic aorta consistently caused transection of the aorta at the isthmus between the spine and anterior bony structures. Analysis of rotation of the first rib in 10 consecutive patients undergoing computed tomography of the chest demonstrated interposition of the distal aortic arch and isthmus between the vertebrae and anterior bony thorax in each instance. Aortas excised from laboratory dogs were pinched between structures simulating bones to reproduce intimal and medial lesions indistinguishable from lesions associated with naturally occurring traumatic disruptions. Although further studies in cadaveric specimens are necessary to confirm this mechanism of injury, the authors believe that their results support the osseous-pinch mechanism of aortic rupture.

Animals↗

The value of quantitative sacroiliac scintigraphy in detection of sacroiliitis.

To evaluate clinical usefulness of quantitative sacroiliac scintigraphy (QSS) in detecting sacroiliitis, we used a modified, pixel by pixel technique for calculating sacroiliac joint/sacrum uptake ratios (sacroiliac joint index - SII). We studied 90 controls, 18 selected patients with active sacroiliitis, 2 ankylosing spondylitis patients with completely ankylosed sacroiliac joints, 14 patients with nonspecific low back pain and 5 patients with rheumatoid arthritis. In the controls, we found that the SII decreases with increasing age (P less than 0.001) and is higher in males than in females (P less than 0.005). In the patients with active sacroiliitis, 9 out of 14 older than 30 had an abnormal SII; 3 of these patients showed no radiographic or CT abnormalities of the sacroiliac joints. None of the 4 patients with sacroiliitis under 30 years of age had values which fell out of the normal range for their age and sex. Only 1 of the 14 patients with non-inflammatory low back pain had an abnormally high SII. A borderline SII was found in 1 of the 5 patients with rheumatoid arthritis. QSS may be useful in detecting active sacroiliitis, sometimes even before the occurrence of radiologic abnormalities. However, because of its low sensitivity, its clinical usefulness is limited, especially in patients under 30 years of age.

Adolescent↗

Centralized, automated chemical-delivery system.

The authors describe the design of a dispensing system which supplies chemicals to ten widely dispersed film processors from centralized bulk-storage feed tanks. Features include a safety circuit which disables a faulty processor in the event of pump malfunction and centralized monitoring of the developer-tank temperature for each processor.

Radiographic Image Enhancement↗

Performance of evaluation of computed tomography scanners using a phantom model.

A phantom was designed to test computed tomography (CT) scanner performance relative to spatial resolution, contrast resolution, field uniformity, spatial linearity, artifact resistance, and radiation dose. Translate/rotate, stationary detector with rotating x-ray tube, and rotate-only scanners were tested under conditions that produced the best possible results for each machine within the dose ranges used in clinical practice. Machines can be ranked according to results for each parameters tested. The range of performance exhibited on machines tested was unrelated to class of scanner. Further, machine dedication to a particular body region did not necessarily secure superior results for that region. Spatial resolution at low contrast levels (poor on most machines) seems to be the most sensitive test of performance.

Humans↗