Initial assessment of the performance of an 0.3 T permanent magnet in whole body NMR imaging.

An 0.3 Tesla permanent magnet was constructed and incorporated into a complete whole body NMR imager. Axial, sagittal and coronal images from human subjects were obtained using a two-dimensional Fourier Transform analysis of selected planes 8 mm thick, combined with an efficient multislice technique that produces sections centered 12 mm apart. Images were obtained based on inversion recovery and spin echo modes. The permanent magnetic field is uniform to 10 ppm over 38 cm. The magnet requires no special maintenance and has an extremely small fringe field. The magnet design, with its field vertical to the long axis of the subject, permits use of a solenoidal radiofrequency receiving coil for optimal signal-to-noise ratio. Images were shown that are of high quality and produced under conditions simulating those necessary for efficient patient throughout in a clinical setting. Many of the unique features of NMR imaging, such as ability to directly obtain axial, sagittal and coronal projections, the variety of imaging modes, the natural sources of contrast, and the ability to visualize clearly medium and large blood vessels, were demonstrated.

Adipose Tissue↗

Accessory equipment considerations with respect to MRI compatibility.

The MR Section of The National Electrical Manufacturers Association (NEMA), in response to a request from the Food & Drug Administration (FDA), recently issued a position paper to address generic issues related to the compatibility of accessory equipment produced by third party equipment manufacturers or MR equipment users and intended to be used in conjunction with MR equipment or within the MR scanning room. The recommendations concern scanning accessories, such as radiofrequency (RF) coils, patient monitoring equipment and injectors, as well as patient comfort accessories and positioning devices. The following issues related to safety performance are discussed: (a) the interaction of the equipment with the MR scanner, (b) interactions of the MR scanner with the equipment, and (c) potential safety hazards for patients and staff that can be posed by accessory equipment in the MR scan environment. The recommendations are based on combined input from NEMA member companies who manufacture MR systems and MR accessories and are presented for consideration in the design of MR accessory products and incorporation of these concepts into testing plans to ensure MR compatibility of third party devices.

Equipment Design↗