PubMed Health⌕ Search

Biomedical subjects

E Kotter

Publications and source records attributed to E Kotter.

At least 19 recordsLinked to original sources

Detection and characterization of benign focal liver lesions with multislice CT.

MDCT is a rapidly evolving technique that significantly improves CT imaging for several indications including depiction of focal benign lesions. Imaging mainly profits from improved longitudinal spatial resolution allowing high-quality non-axial reformations and 3D reconstructions and CT angiography as well as rapid accurate multiphase imaging with short breath-holding periods. This review provides an overview of the current status of MDCT with respect to liver imaging and the implications for characterizing benign focal liver lesions. MDCT currently allows the acquisition of thin slices in daily routine diagnostics providing an improved detection rate of small liver lesions. Whereas large benign focal liver lesions exhibit typical patterns of morphology, attenuation and perfusion, which also may be assessed with single-slice scanners, small lesions remain challenging even with MDCT, since the specific criteria for confident diagnosis become more ambiguous. Here, MR imaging provides more detailed information about tissue components and the availability of liver-specific contrast agents, adding further impact to this technique. With respect to dose considerations, the number of necessary multiphase scans as well as the application of very thin collimation should be strictly checked for each patient undergoing MDCT based on the individual clinical situation and question.

Adenoma, Liver Cell↗

Serial high-resolution computed tomography imaging in patients with Wegener granulomatosis: differentiation between active inflammatory and chronic fibrotic lesions.

PURPOSE: To evaluate pulmonary pathologies in Wegener granulomatosis with sequential computed tomography (CT) in order to differentiate active inflammatory lesions from chronic fibrotic lesions. MATERIAL AND METHODS: Serial CT findings in 38 patients with Wegener granulomatosis were retrospectively analyzed (mean follow-up period, 21 months). The presence, extension, and distribution of the following findings were evaluated with CT: parenchymal nodules, masses, ground-glass attenuation, airspace consolidation, bronchial wall-thickening, bronchiectasis, linear areas of attenuation, pleural irregularities, pleural effusions, hilar and mediastinal lymphadenopathy. RESULTS: Observed in 92% of patients, nodules were the most common CT pathology. Areas of ground-glass attenuation, consolidation, masses of linear attenuation, and tracheal/bronchial wall-thickening were detected in 24%, 26%, 32%, 39%, and 68% of patients. At follow-up, the clearance of lesions was most consistent for areas of ground-glass attenuation (89%), masses (87%), and cavitated nodules (85%). In the follow-up scan, 58% of all nodules, 47% of pulmonary consolidations, and 66% of bronchial wall-thickening were completely resolved. Areas of bronchiectasis and septal/non-septal lines remained stable in 70% and 71% of patients. CONCLUSION: The majority of the lesions decreased or resolved completely with or without areas of linear attenuation. Ground-glass attenuation, cavitated nodules and masses appear to represent active inflammatory lesions. In most probability, areas of bronchiectasis and septal/non-septal lines more often represent chronic fibrotic changes rather than active inflammatory changes. In combination with clinical evaluation and bronchoscopy, CT assists in the assessment of disease activity.

Adult↗

Endovascular treatment of superficial femoral artery occlusive disease with stents coated with diamond-like carbon.

A major consideration in the reduction of early stent thrombosis and in-stent restenosis is the improvement of biocompatibility of the devices. Diamond-like carbon is a novel material for coating stent surfaces in order to increase biocompatibility. The authors report on the endovascular treatment of two individuals with superficial femoral artery occlusions, using stents coated with diamond-like carbon. Technical and clinical success was achieved in both cases, with primary patency rates of 100% 12 months after intervention.

Aftercare↗

Background suppression using magnetization preparation for contrast-enhanced 3D MR angiography of the pelvic and lower leg arteries.

PURPOSE: To develop and evaluate non-slab-selective magnetization preparation in contrast-enhanced 3D-MR angiography. METHODS: An ultrafast spoiled mr angiography sequence (FLASH) with non-selective inversion prepulses for background suppression was implemented on a 1.5 T MR system. In 11 patients gadobenate dimeglumine-enhanced mr-angiography of the pelvic and lower leg arteries was performed using the AngioSURF device. Source data was evaluated for contrast-to-noise-ratio, image quality and the extent of background suppression. RESULTS: Background suppression and selective vessel contrast was excellent in all vascular levels. The mr protocol was comfortable and easy-to-handle. Abandonment of precontrast-series acquisition simplified the examination procedure markedly. CONCLUSIONS: Magnetization preparation provides efficient suppression of the background signal in contrast-enhanced 3D mr angiography of the pelvic and lower leg arteries. Since no subtraction technique is needed, moving-bed and whole body MRA-protocols can be simplified significantly.

Adult↗

[Electronic distribution of patient records and images through PACS: implementation of data protection at the University Hospital in Freiburg].

In large installations of a Picture Archiving and Communication System (PACS), data protection becomes an issue. Above all, not every employee should have access to all data stored in the system. At the Freiburg University Hospital, we developed a concept of dynamic assignment of authorization, assuring that every physician is authorized to the data of all patients under his care. We describe the technical implementation of data protection developed for the integration of PACS and electronic patient records in Freiburg. The system was installed in January 2001 and the experience of its two years in operation is reported.

Computer Security↗

Using receiver operating characteristic methodology to evaluate the diagnostic quality of radiography on paper prints versus film.

OBJECTIVE: The aim of this study was to compare the diagnostic quality of paper prints with film copies in a sample of observers who were trying to detect small coin lesions on radiographs of a phantom. MATERIALS AND METHODS: The phantom consisted of 60 high-contrast and 60 low-contrast test objects, half of which had holes in them. Diameter and depth of the holes varied from 0.5 mm to 2 mm. Fifteen radiographs were obtained from different areas of the test objects. Film copies and paper prints were made using high-quality printers. Five observers independently evaluated 1,800 high-contrast and 1,800 low-contrast images. Data were evaluated using the well-established receiver operating characteristic methodology. RESULTS: The mean area under the curve rated 0.863 for paper prints (0.859 for high contrast and 0.860 for low contrast) and 0.926 for laser films (0.937 for high contrast and 0.913 for low contrast). The difference between the two imaging techniques was statistically significant for both high- and low-contrast lesions (p < 0.05). CONCLUSION: Detection of small coin lesions on radiographs of a phantom was significantly less sensitive on paper prints than on film. We found paper prints less acceptable for the diagnosis of small-sized lesions.

Diagnostic Errors↗

Digital radiography with large-area flat-panel detectors.

Large-area flat-panel detectors with active readout mechanisms have been on the market for the past 2 years. This article describes different detector technologies. An important distinction is made between detectors with direct and those with indirect conversion of X-rays into electrical charges. Detectors with indirect conversion are built with unstructured or structured scintillators, the latter resulting in less lateral diffusion of emitted light. Some important qualities of flat-panel detectors are discussed. The first phantom and clinical studies published report an image quality at least comparable to that of screen-film systems and a potential for dose reduction. The available studies are summarised in this article.

Humans↗

[Image quality of paper prints compared to film copies in CT investigations].

PURPOSE: Evaluation of image quality of paper prints in routine CT investigations. METHOD: The image quality of paper prints from 104 CT scans of daily routine investigations was analysed by three observer three observers according to a five-point ranking scale for contrast, grey level, spatial resolution, and subjective confidence in correct evaluation. Each study was rated "acceptable" or "not acceptable for documentation". RESULTS: In 312 ratings the mean grade for contrast was 2.7, for grey levels 3.2, and for spatial resolution 3.3. Grades ranged from 1 = very good to 5 = insufficient. Subjective confidence in correct evaluation was rated as "certain" in 77.4 %, "likely" in 18.4 % and "impossible to evaluate" in 4.2 % of cases. 93.7 % of printed CT images were rated "acceptable for documentation". CONCLUSION: Image quality of paper prints does not reach the quality of laser films concerning its contrast, grey levels, and spatial resolution. Nevertheless, paper prints are acceptable for documentation of findings in most CT investigations. A high confidence in correct evaluation was found. Limitations are found in documentation of small coin lesions of the lung and ischemic lesions of the neurocranium.

Humans↗

Networks in the radiology department and the hospital.

Data networks are a basic technology with regard to an appropriate design of the information technology (IT) infrastructure for the hospital. Due to the distributed workflow within the hospital, an integrated Hospital Information System (HIS) is based mostly on a set of network applications facing specific items. Medical communication standards, i.e., HL 7, DICOM, and in the near future the migration towards XML, support the interoperability between the IT subsystems and pave the way to patient information systems with access to unified and complete electronic medical records (EMR). Furthermore, with standardized communication techniques, such as CORBAmed, an object-oriented design of Healthcare applications will be possible in the near future. The intent of this paper is to give an overview of which basic technologies are suitable for building comprehensive, flexible, and reliable hospital networks and which also meet the special demands of the radiology department.

Computer Communication Networks↗

[Quality assessment using AGIR: results and experience].

PURPOSE: To evaluate whether a new software from the working group for interventional radiology (AGIR) is an appropriate tool for quality assurance in interventional radiology, and presentation of results acquired within the quality improvement process in 1999. PATIENTS AND METHODS: AGIR-defined parameters such as patient data, risk profile, given interventions as well as complications were registered by a recently developed software. Based on monthly data analyses, possible complications were identified and discussed in morbidity and mortality conferences. RESULTS: 1014 interventions were performed in our institution in 1999. According to criteria established by AGIR, the complication rate was 2.7%. In addition and according to SCVIR criteria, complications were distinguished quantitatively in five classes and semiquantitatively in minor and major groups. The result was a minor complication rate of 1.8%, and a major rate of 0.9%. There were no cases of death associated with the intervention. Further strategies were developed in order to reduce the complication rate. CONCLUSION: Extensive quality assurance methods can be integrated in daily routine work. These methods lead to an intensive transparency of treatment results, and allow the implementation of continuous quality improvements. The development of the software is a first step in establishing a nation-wide quality assurance system. Nevertheless, modification and additional definition of the AGIR predefined parameters are required, for example, to avoid unnecessary procedures.

Adolescent↗

[RIS modality interfaces. From proprietary solutions to DICOM worklist management].

Radiologic information systems (RIS) and picture archiving and communication systems (PACS) are becoming increasingly widespread. This leads to new demands on the integration of the individual, formerly independent information systems (RIS, modalities, PACS). Possible ways of integrating individual systems are introduced. Besides the detailed description of different realizations of system communication, its role in the PACS at the university hospital in Freiburg is explained. The integration of different information systems still requires the use of proprietary interfaces. An appropriate integration generally has been realized in Freiburg. In the near future DICOM basic worklist management will standardize system integration and render an interdepartmental workflow concept possible. Even though an available communication standard exists, not all problems in the RIS-modality interface are solved. Different data models in the various RI systems and modalities demand certain degrees of freedom in the standard. Thus a satisfactory workflow cannot be guaranteed even when all involved systems conform with the standard.

Germany↗

[Modern network technologies for data communication in the hospital].

Modern network technologies provide the basic infrastructure for information and communication systems in the hospital today. The goal to build up a universal network infrastructure which meets the broadly varied requirements. Analysis of data communication in the hospital and the evaluation of established network technologies, as well as new developments, leads to the switching concept as the suitable solution. Two technologies play the major role in building enterprise networks: the Ethernet family, based on frame switching, and ATM, based on cell switching. Orientation on established standards is the key to free system choice and grants interoperability between systems from different manufacturers. However, the network design must meet the application and system architecture of the information technology in order to achieve successful mapping of the involved communication profiles. This means scaling of the bandwidth as needed, suitable segmenting of the network and resilient links. In a further step, policy-based networking takes advantages of prioritizing critical applications and therefore reduces interdependencies across the network.

Computer Systems↗

Comparison between a screen-film system and a selenium radiography system. An ROC study using simulated thoracic lesions.

RATIONALE AND OBJECTIVES: To evaluate the diagnostic image quality of the hard copies of a commercially available selenium detector-based computed radiography system compared to that of a conventional screen-film system. METHODS: Ten radiographs of an anthropomorphic chest phantom with simulated nodular and linear-reticular lesions were produced using either system. Each radiograph was subdivided into 15 fields containing zero lesions, one nodular lesion, one linear-reticular lesion, or both lesions. The total of 150 fields for each modality was reviewed by six radiologists, and receiver operating analysis was performed. RESULTS: The conventional screen-film system performed significantly better for nodular lesions, whereas no statistically significant difference was found between the detection rates of both systems for linear-reticular lesions. CONCLUSIONS: The better detection of nodules with the dedicated selenium detector can be explained by the higher dynamic range of the system. Detection of linear-reticular lesions was slightly but not significantly better with the screen-film system, but the detection rate of the selenium detector might be further improved with a different image processing technique.

Humans↗

Pelvic imaging with a selenium-based detector (Thoravision). Comparison with screen-film radiography in 75 patients.

OBJECTIVE: To evaluate whether the selenium detector (Thoravision) provides sufficient diagnostic confidence in digital pelvic imaging compared with a conventional screen-film combination. METHODS: In 75 patients, pelvic imaging with conventional screen-film and isodose selenium radiography using a dedicated postprocessing mode was compared independently by three radiologists. The depiction of cortical and cancellous bone was evaluated in the iliac wings, sacral and pubic bones, acetabulum, femoral head, and trochanter. Demarcation of soft tissue was assessed in the iliac and trochanteric region. RESULTS: Visualization of cortical bone and soft tissue in the iliac area as well as soft tissue and cortical and cancellous bone in the trochanteric region was significantly superior with the selenium detector. However, conventional imaging was better in the trabecular bone of the sacral region, where results with the selenium system were particularly poor. CONCLUSIONS: The selenium detector (Thoravision) is advantageous in imaging soft tissue adjacent to the iliac wings and the trochanter, but results for the cancellous sacral bone are poor. Further modifications of postprocessing modes may lead to improved depiction of this critical pelvic area.

Adult↗

Integrating HIS-RIS-PACS: the Freiburg experience.

With the integration of different formerly isolated information systems, such as Hospital Information System (HIS). Radiology Information System (RIS), Picture Archiving and Communication System (PACS) and modalities, we evolve towards an architecture of distributed information processing in radiology, the data being stored in distributed databases. The frontier between the cooperative information systems becomes more subtle than in the past, and it seems more convenient to distinguish the different computer functionalities or services used in radiology than to detail the functions of RIS and PACS. This paper opens with a description of the different computer services used in radiology and how they relate one to another. It also shows how these functionalities could be integrated within a global Radiology Information and Archiving System. Finally, it shows the degree of systems interconnection that can be achieved presently, using the PACS-RIS installation at the University Hospital of Freiburg as an example.

Computer Communication Networks↗

Experience with PACS in an ATM/Ethernet switched network environment.

Legacy local area network (LAN) technologies based on shared media concepts are not adequate for the growth of a large-scale picture archiving and communication system (PACS) in a client-server architecture. First, an asymmetric network load, due to the requests of a large number of PACS clients for only a few main servers, should be compensated by communication links to the servers with a higher bandwidth compared to the clients. Secondly, as the number of PACS nodes increases, the network throughout should not measurably cut production. These requirements can easily be fulfilled using switching technologies. Here asynchronous transfer mode (ATM) is clearly one of the hottest topics in networking because the ATM architecture provides integrated support for a variety of communication services, and it supports virtual networking. On the other hand, most of the imaging modalities are not yet ready for integration into a native ATM network. For a lot of nodes already joining an Ethernet, a cost-effective and pragmatic way to benefit from the switching concept would be a combined ATM/Ethernet switching environment. This incorporates an incremental migration strategy with the immediate benefits of high-speed, high-capacity ATM (for servers and high-sophisticated display workstations), while preserving elements of the existing network technologies. In addition, Ethernet switching instead of shared media Ethernet improves the performance considerably. The LAN emulation (LANE) specification by the ATM forum defines mechanisms that allow ATM networks to coexist with legacy systems using any data networking protocol. This paper points out the suitability of this network architecture in accordance with an appropriate system design.

Local Area Networks↗

Cine-MR imaging of the shoulder.

PURPOSE: Shoulder lesions are usually examined with the joint in only one or two positions. We examined the shoulder with the joint in a variety of positions. We also assessed the application of cine-MR to the detection of instability and impingement. MATERIAL AND METHODS: The cine-MR examinations were performed in 30 patients and 15 healthy volunteers. We used an open 0.2 T system and a closed 1.0 T system. Spoiled gradient echo 2D T1-weighted images and turbo spin-echo T1- and T2-weighted images were obtained with a field of view of 180 mm. The examinations were videotaped and evaluated later. RESULTS: Normal variations of the glenohumeral joint were easy to recognize. Sub-luxations and luxations of the humeral head as well as rupture of the labrum were identified. It was also possible to identify the labrum with a signal change after arthroscopic refixation. And we were able to objectively assess distances between the osseous structures during dynamic movement. CONCLUSION: Unlike static MR, cine-MR would appear to be useful in visualizing the capsular ligament complex of the gleno-humeral joint in impingement and instability. It also provides information on dynamic changes and may thus prove to be an important tool for shoulder diagnostics. The method may provide an early diagnosis in the sub-acromial impingement syndrome.

Acromion↗