PubMed Health⌕ Search

Biomedical subjects

E L Alderman

Publications and source records attributed to E L Alderman.

At least 55 records · Page 3Linked to original sources

Effect of completeness of revascularization on long-term outcome of patients with three-vessel disease undergoing coronary artery bypass surgery. A report from the Coronary Artery Surgery Study (CASS) Registry.

BACKGROUND: Complete revascularization after coronary artery bypass surgery is a logical goal and improves symptomatic outcome and survival. However, the impact of complete revascularization in patients with three-vessel coronary disease with varying severities of angina and left ventricular dysfunction has not been clearly defined. METHODS AND RESULTS: The study was performed as a retrospective analysis of 3,372 nonrandomized surgical patients from the Coronary Artery Surgery Study (CASS) Registry who had three-vessel coronary disease. Group 1 (894 patients) had class I or II angina (Canadian Cardiovascular Society criteria) and group 2 (2,478 patients) had class III or IV angina. In group 1, adjusted cumulative 4-year survivals according to the number of vessels bypassed were 85% (one vessel), 94% (two vessels), 96% (three vessels), and 96% (more than three vessels) (log rank, p = 0.022). Adjusted event-free survival (death, myocardial infarction, definite angina, or reoperation) was not influenced by the number of vessels bypassed, nor was the anginal status among patients remaining alive after 5 years. In group 2, adjusted cumulative 5-year survivals were 78% (one vessel), 85% (two vessels), 90% (three vessels), and 87% (more than three vessels) (log rank, p = 0.074). Adjusted event-free survivals after 6 years were 23% (one vessel), 23% (two vessels), 29% (three vessels), and 31% (more than three vessels) (p = 0.025); at 5 years, those with more complete revascularization were more likely to be asymptomatic or free of severe angina. Among group 2 patients with ejection fractions less than 0.35, 6-year survival was 69% for those with grafts to three or more vessels versus 45% for those with grafts to two vessels (p = 0.04). Placing grafts to three or more vessels was independently associated with improved survival and event-free survival in group 2 but not group 1 patients. The case-fatality rates among 529 patients experiencing a myocardial infarction during follow-up was significantly higher for patients with less complete revascularization. CONCLUSIONS: Complete revascularization (grafts to three or more vessels) in patients with three-vessel coronary disease appears to most benefit those with severe angina and left ventricular dysfunction.

Angina Pectoris↗

Detection of coronary atherosclerosis in young adult hearts using intravascular ultrasound.

BACKGROUND: Coronary atherosclerosis has been demonstrated in young adults by postmortem pathology. Angiographic evaluation of coronary disease in young adults is limited by ethical issues and the insensitivity of angiography for detecting early pathology. Catheter-based intracoronary ultrasound has proven useful both in detecting and quantitating coronary disease, but the ultrasound appearance of young, angiographically normal, coronary arteries has not been well defined. METHODS AND RESULTS: Twenty-five subjects were examined with intracoronary ultrasound within 1 month of cardiac transplantation. Mean age of the donor hearts was 28 years (range, 14-43 years). Measurements of an index of intimal thickening were obtained at four left anterior descending coronary artery sites in each patient. All study patients had angiographically normal coronary arteries. Ultrasound in 14 subjects demonstrated a three-layered appearance of the coronary vessel wall with a mean intimal index of 0.16 +/- 0.07. The other 10 subjects, including all donors under the age of 25 years, had coronary vessel wall layers too thin to be imaged separately at the 30-MHz sound frequency. Five subjects had ultrasound evidence of focal intimal thickening greater than 500 microns. The donors of these hearts each had risk factors for coronary artery disease. Two subjects died within 5 weeks of their ultrasound study. Histological measurements of the vessel wall layers were similar to the corresponding ultrasound values. CONCLUSIONS: This study provides a reference for the intravascular ultrasound appearance of young adult coronary arteries and confirms pathology findings that young subjects with angiographically normal vessels have a range of coronary intimal thickening, which includes occasional evidence of focal, early atheromatous lesions.

Adult↗

Effects of the pericardium on left ventricular diastolic filling and systolic performance early after cardiac operations.

To determine whether closure of the pericardium after cardiac operations affects the filling characteristics and systolic performance of the left ventricle, we measured left ventricular volume, pressure, cardiac index, and stroke work index in 10 patients between 11 and 15 hours after cardiac operations, with the pericardium first closed and then open. At the time of operation, radiopaque tantalum markers were inserted in the left ventricular myocardium to outline the chamber in the 30-degree right anterior oblique projection, and the pericardium was closed by a continuous polypropylene suture exteriorized at both ends of the sternotomy. The patient was then transferred to the surgical intensive care unit, where left atrial pressure was measured via a fluid-filled catheter, left ventricular pressure with a micromanometer-tipped catheter, and myocardial oxygen consumption via a coronary sinus catheter. Left ventricular volume was measured by computer-aided analysis of fluoroscopic images (recorded at 30 frames per second) of the implanted myocardial markers. Left atrial pressure was maintained at target values of 10, 15, and 20 mm Hg by intravenous augmentation of blood volume. Left ventricular and left atrial pressures and volumes were measured with the pericardium closed; the pericardium was then opened by withdrawal of the pericardial suture. Radiopaque clips on the pericardial edges confirmed opening of the pericardium seconds after withdrawal of the suture. Repeated measurements of left ventricular pressures and volumes were then made at the target left atrial pressures with the pericardium open. End-diastolic volume index, peak positive time derivative of pressure, stroke work index, and cardiac index all increased significantly when the pericardium was opened (p < 0.001). Thus we found the following: (1) At physiologic pressures, the pericardium had a significant constraining effect on diastolic filling of the left ventricle, and (2) opening of the pericardium resulted in increased cardiac index and stroke work index. These increases may be attributed to the Frank-Starling response to increased left ventricular preload. The demonstrated improvement in left ventricular systolic performance should be considered when contemplating closure of the pericardium after cardiac operations, especially in patients with preoperative left ventricular dysfunction.

Adult↗

Anatomic and machine projection angles of various radiographic imaging systems used for cardiac angiography.

Quantitation of coronary artery dimensions in serial angiographic studies requires an awareness of the variety, complexity, and implications of radiographic imaging equipment used for coronary arteriography. Recognition of the geometric complexities inherent in angiographic imaging systems is important in understanding complex image rotations and ensuring identity of projections when serial comparison is desired. Tables, figures, and formulae are provided to permit translation of machine angles into patient reference angles and vice versa.

Angiography↗

Coronary artery quantitation and data management system for paired cineangiograms.

A computerized system designed to optimize the quantitation of coronary vessels on 35 mm cineangiograms is described and validated. Because the system has two cine film digitizers, it processes paired coronary arteriograms for the evaluation of serial changes in coronary arteries. A database system was specifically designed for the storage of coronary artery quantitation data which resides on a file server in a local area network and may be accessed by multiple workstations. In radiographic phantom studies of nine contrast-filled lucite cylinders of known size, the overall accuracy and precision for the measured diameters were 0.069 mm and 0.066 mm respectively. Measurements of minimum diameter and percent diameter stenosis of 21 coronary lesions selected from 17 routine cineangiograms showed high degree of intraobserver and interobserver reproducibility.

Cineangiography↗

Intravascular ultrasound imaging of angiographically normal coronary arteries: an in vivo comparison with quantitative angiography.

Intravascular ultrasound, a new technique for real-time two-dimensional visualization of arteries and veins, delineates vessel wall morphology and measures luminal dimensions. This imaging method has been validated with in vitro systems and in peripheral vessels, but there are few in vivo coronary artery studies. Twenty cardiac transplant recipients with no angiographic coronary artery disease were scanned with a 30-MHz intravascular ultrasound catheter from the left main coronary ostium to the mid-left anterior descending coronary artery. Simultaneous angiographic measurements were performed at 76 sites. Ultrasound end-diastolic diameters in two perpendicular axes were 3.8 +/- 0.9 and 3.9 +/- 0.6 mm, respectively, and mean diameter derived from an area determined by planimetry was 3.9 +/- 0.9 mm. Angiographic coronary artery diameters measured with a computer-assisted edge detection system perpendicular to the long axis of the vessel and to the long axis of the catheter were 3.4 +/- 0.8 and 3.6 +/- 0.8 mm, respectively. Luminal diameters measured with the two imaging systems correlated closely, with an r value of 0.86 when ultrasound was compared with the angiographic diameter measured perpendicular to the vessel and 0.88 when compared with the angiographic diameter measured perpendicular to the imaging catheter. Eighty-three percent of the ultrasound-measured diameters were above the line of identity when compared with the simultaneous angiographic measurement. The more the imaging catheter deviated from the long axis of the vessel, the greater was the discrepancy between the ultrasound and angiographic measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography↗

Transplant coronary artery disease: histopathologic correlations with angiographic morphology.

Accelerated coronary artery disease is a major cause of morbidity and mortality among cardiac transplant recipients. Ten patients who died or underwent retransplantation within 2 months of coronary angiography had direct correlation of angiographic (normal discrete lesions, diffuse concentric narrowing) with histologic appearance of coronary arteries. Of the 26 angiographically normal segments, 73% showed mild to moderate fibrous intimal thickening by light microscopy. The remainder had intermediate lesions or atheromatous plaques. Discrete stenoses usually corresponded to lipid-rich intermediate or atheromatous disease. In contrast, angiographically diffuse, concentrically narrowed lesions usually were areas of severe fibrous intimal thickening. Fresh or organizing thrombus was most often associated with discrete lesions and accounted for all complete occlusions. Histologic and angiographic comparisons of the degree of luminal narrowing showed generally good correlation for high grade stenoses. Lesions graded as having less than 25% diameter narrowing were often underestimated angiographically as compared with histologic determinations. Transplant coronary artery disease has a heterogeneous histologic and angiographic appearance, with angiographic underestimation of disease in some patients.

Adult↗

Alterations in left ventricular diastolic twist mechanics during acute human cardiac allograft rejection.

BACKGROUND: Contraction of obliquely oriented left ventricular (LV) fibers results in a twisting motion of the left ventricle. The purpose of this study was to assess the effects of acute human cardiac allograft rejection on LV twist pattern and the twist-volume relation. METHODS AND RESULTS: Tantalum markers were implanted into the LV midwall in 15 transplant recipients to measure time-varying, three-dimensional chamber twist using computer-assisted analysis of biplane cinefluoroscopic images. Twist was defined as the mean longitudinal gradient of circumferential rotation about the LV long axis. When plotted against normalized percent ejection fraction (%EF), the resulting twist-normalized %EF relation could be divided into three phases. In systole, LV twist was linearly related to ejection of blood. In contrast, diastolic untwist was characterized by early rapid recoil with little change in LV volume, followed by more gradual untwisting when the bulk of diastolic filling occurred. During 10 acute rejection episodes in 10 patients, maximum twist, peak systolic twist rate, and the slope of the systolic twist-normalized %EF relation did not change. In contrast, the slope of the early (first 15% of filling) diastolic twist-normalized %EF relation (M(early-dia)) decreased significantly (-0.194 +/- 0.062 [prerejection] versus -0.103 +/- 0.054 rad/cm [rejection], p = 0.0003), resulting in a prolonged tau 1/2 (time required to untwist by 50% [20 +/- 5% versus 28 +/- 5% of diastole], p = 0.0003) and decrease in percent untwisting at 15% diastolic LV filling (62 +/- 11% versus 36 +/- 13%, p = 0.0003). Therefore, a greater proportion of LV untwisting occurred later in diastole during rejection, as reflected by an increase in the slope (M(mid-dia)) of the middle to late (from 15 to 90% filling) diastolic twist-normalized %EF relation (-0.018 +/- 0.009 versus -0.030 +/- 0.010 rad/cm, p = 0.0015). Peak rate of untwist was not affected. With resolution of rejection, M(early-dia) and percent untwist during early diastole returned to baseline levels (p = NS versus baseline). There was also a trend for M(mid-dia) to return toward prerejection values (p = NS versus baseline), but this change did not reach statistical significance compared with rejection values. CONCLUSION: Acute cardiac allograft rejection is associated with altered diastolic twist mechanics in the absence of any demonstratable systolic abnormalities. During rejection, myocardial edema and other factors may result in intrinsic changes of the elastic properties of the myocardium, thereby leading to modification of recoil forces responsible for the early, rapid unwinding of the deformed ventricle.

Acute Disease↗

Effect of volume loading, pressure loading, and inotropic stimulation on left ventricular torsion in humans.

BACKGROUND: The transmural distribution of fiber angles and the extent of shortening among obliquely oriented fibers are likely to be major determinants of the twisting motion that accompanies left ventricular (LV) ejection. As such, measurements of torsion may provide useful information about LV contractile function, but other factors, such as ventricular loading conditions, may also regulate this motion. METHODS AND RESULTS: Torsion angles (theta i) of midventricular and apical regions were measured relative to a reference minor axis near the base in seven human cardiac allografts from biplane radiographic images of metallic midwall markers. Pressure loading with methoxamine (5-10 muk/kg/min) increased LV end-systolic pressure by 41 +/- 14 mm Hg (p less than 0.0001). Volume loading with normal saline raised LV end-diastolic pressure from 9.9 +/- 5.2 to 19.6 +/- 4.9 mm Hg (p less than 0.0001). These alterations in LV loading conditions were associated with no change in theta i (difference not significant) for any marker site. Inotropic stimulation with dobutamine (5 micrograms/kg/min) increased values of theta i by as much as twofold (p less than 0.05); this response varied considerably depending on marker location, with the middle and apical inferior wall and the apical lateral wall being the most sensitive. When the marker site associated with the largest torsion angle (theta max) was considered in each patient, dobutamine increased theta max in all cases (25.2 +/- 10.5 degrees versus 15.8 +/- 7.7 degrees, p less than 0.001), whereas pressure and volume loading had negligible effects. This 59% increase in theta max was greater than that of conventional load-dependent indexes of LV systolic performance such as stroke volume (16%), ejection fraction (22%), and maximum rate of LV pressure rise (52%). CONCLUSIONS: This component of LV motion is relatively insensitive to alterations in preload and afterload, while changes in contractile state influence LV torsion in a regionally heterogeneous manner. Quantification of LV torsion may, therefore, provide a sensitive and relatively load-independent measure of contractile performance that may prove to be useful in the serial assessment of LV function.

Cineradiography↗

Determinants of normal coronary artery dimensions in humans.

BACKGROUND: Studies of normal human coronary dimensions have been performed primarily in postmortem hearts. We evaluated the influence of age, body habitus, and regional myocardial mass on coronary dimensions in living patients with normal coronary vessels. METHODS AND RESULTS: Arteriographically normal coronary angiograms were analyzed from the following groups of subjects: group 1 (age, 15-34 years) consisted of 30 post-cardiac transplant patients with donor hearts from male subjects aged 15-34 years, group 2 (age, 35-54 years) consisted of 12 post-cardiac transplant patients with donor hearts from male subjects aged 35-54 years and 26 male subjects investigated for atypical chest pain, and group 3 (age, 55-74 years) consisted of 26 male subjects investigated for atypical chest pain. All angiograms were performed after sublingual nitroglycerin. Measurements of the dimensions of the left main, proximal left anterior descending, proximal left circumflex, and proximal right coronary arteries were made using a computer-assisted edge-detection algorithm. The regional myocardial mass supplied by each vessel was derived from echocardiographically derived total left ventricular mass and a semiquantitative angiographic territory scoring system based primarily on the number and length of its terminal nutrient branches. CONCLUSIONS: Linear regression analysis showed that coronary vessel cross-sectional area and total coronary cross-sectional area increase with regional myocardial mass and decrease linearly with age. Multivariate regression analysis revealed that regional myocardial mass and age were independent predictors of cross-sectional area for each vessel and for the total coronary cross-sectional area. We speculate that age-related decline in physical activity, in part, may be responsible.

Adolescent↗

Evaluation of catheters and metallic catheter markers as calibration standard for measurement of coronary dimension.

Measurement of coronary dimension requires an accurate and reproducible dimensional reference. Angiographic catheters are frequently used for this purpose. We measured the angiographic diameters of a broad range of diagnostic and angioplasty guiding catheters by using two commonly used edge-detection algorithms. Angiographic diameters are significantly less than true catheter outer diameter. Therefore the use of contrast-filled catheters as a dimensional reference may lead to considerable error in vessel measurement with overestimation of absolute dimension. Tables of reference values for multiple catheter as calibration standard, tested under a variety of angiographic conditions. The metallic-tipped marker was found to have a better degree of reproducibility than catheters. These findings have implications for studies employing serial measurements of coronary artery dimension and for the clinical practice of estimating vessel diameter for choice of balloon size during angioplasty.

Calibration↗

Effects of nitroprusside on transmitral flow velocity patterns in extreme heart failure: a combined hemodynamic and Doppler echocardiographic study of varying loading conditions.

To explore the mechanisms of change of left ventricular diastolic filling associated with preload and afterload reduction, the influence of nitroprusside on the transmitral flow velocity pattern, pulmonary capillary wedge pressure and left ventricular pressure interaction was studied in 11 patients with end-stage heart failure. Pulsed Doppler echocardiographic recordings of mitral inflow were obtained with simultaneous high fidelity left ventricular and phase-corrected pulmonary capillary wedge pressure recordings before and during levels of nitroprusside infusion. With nitroprusside, left ventricular systolic and end-diastolic pressures decreased by 14% and 41% (p less than 0.05, p less than 0.05), respectively, and cardiac output increased by 67% (p less than 0.05). The pulmonary capillary wedge-left ventricular crossover pressure decreased by 41% (p less than 0.05), but the time constant of isovolumetric left ventricular pressure decrease T was insignificantly changed. Isovolumetric relaxation time and acceleration and deceleration times of the early diastolic filling wave were significantly prolonged with nitroprusside infusion (p less than 0.05, p less than 0.05 and p less than 0.05, respectively). Peak early diastolic filling velocity was maintained (65 +/- 11 to 62 +/- 13 cm/s, p = NS) in spite of the decreased absolute crossover pressure. Changes in peak early diastolic filling velocity correlated weakly with changes in the crossover pressure (r = 0.48, p less than 0.05) and correlated better with the crossover to left ventricular minimal pressure difference (r = 0.78, p less than 0.05). Peak early diastolic filling velocity appears to be most affected by the early diastolic pulmonary capillary wedge to left ventricular pressure difference rather than the absolute pulmonary capillary wedge pressure. The lack of peak flow velocity change during nitroprusside infusion could be explained by either the associated decrease in left ventricular minimal pressure or downward shift of left ventricular diastolic pressure by the same amount as the decrease in pulmonary capillary wedge pressure. This may reflect a reduction of external constraint to ventricular distensibility produced by a reduction in filling volume in patients with a markedly dilated ventricle. Thus, a prolonged early diastolic filling period and preserved peak early diastolic filling velocity in spite of decreased left ventricular filling pressure and constant relaxation rate are associated with the beneficial effects of nitroprusside on left ventricular function in patients with severe congestive heart failure.

Blood Flow Velocity↗

Three-dimensional left ventricular midwall dynamics in the transplanted human heart.

To quantify the three-dimensional regional dynamics of the left ventricular (LV) midwall and the centroid and cross-sectional shape of the LV chamber in the transplanted human heart, 12 miniature radiopaque tantalum markers were implanted in the LV midwall of the donor heart at the time of cardiac transplantation in 15 patients. Stereo cineradiography in the late postoperative period (mean, 52 days after surgery) allowed computer-aided measurements of the three-dimensional coordinates of multiple sites in anterior, inferior, lateral, and septal LV regions at 16.7-msec intervals throughout the cardiac cycle. In awake, supine patients, from maximum to minimum LV volume, group mean translations of free wall markers ranged from 0.80 to 1.24 cm, directed toward the LV interior, whereas translations of septal wall markers were significantly less, 0.46 and 0.34 cm (p less than 0.01), directed away from the LV interior. A component of this translation along the septal-lateral axis was also significantly less (p less than 0.01) in the septum (0.19 and 0.20 cm) than in the free wall, where it ranged from 0.32 to 0.97 cm. The LV cross section was not circular, and anterior-inferior dimensions (7.18 +/- 0.66 and 6.13 +/- 0.79 cm, at maximum and minimum volumes, respectively) were significantly greater (p less than 0.01) than septal-lateral dimensions (5.78 +/- 0.65 and 5.12 +/- 0.48 cm), yielding an unchanging transverse elliptical LV eccentricity (0.58 +/- 0.13). The position of the LV center of volume did not change significantly from maximum to minimum volume in the direction of either the LV long axis or the anterior-inferior axis, but it did change significantly (0.55 +/- 0.23 cm, p less than 0.01) along the septal-lateral axis. We conclude 1) as viewed in a fixed external reference system, midwall sites in the interventricular septum of the transplanted human heart move paradoxically yet are relatively immobile compared with the three-dimensional dynamics of midwall sites in the LV free wall; 2) the transverse cross-sectional shape of the LV in the transplanted human heart is decidedly oval, with significantly greater anterior-posterior than septal-lateral dimensions at the time of maximum and minimum LV volumes; and 3) the center of volume in the transplanted human LV is remarkably stable in the directions of the LV long axis and anterior-posterior axis, suggesting a balance of forces along these axes, yet it moves significantly toward the interventricular septum, presumably counterbalancing the opposite translation during systole of the right ventricular (RV) center of volume.(ABSTRACT TRUNCATED AT 400 WORDS)

Cardiac Volume↗

Ten-year follow-up of survival and myocardial infarction in the randomized Coronary Artery Surgery Study.

The Coronary Artery Surgery Study (CASS) randomized 780 patients to an initial strategy of coronary surgery or medical therapy. Of medically randomized patients, 6% had surgery within 6 months and a total of 40% had surgery by 10 years. At 10 years, there was no difference in cumulative survival (medical, 79% vs. surgical, 82%; NS) and no difference in percentage free of death and nonfatal myocardial infarction (medical, 69% vs. surgical, 66%; NS). Patients with an ejection fraction of less than 0.50 exhibited a better survival with initial surgery treatment (medical, 61% vs. surgical, 79%; p = 0.01). Conversely, patients with an ejection fraction greater than or equal to 0.50 exhibited a higher proportion free of death and myocardial infarction with initial medical therapy (medical, 75% vs. surgical, 68%; p = 0.04) although long-term survival remained unaffected (medical, 84% vs. surgical, 83%; p = 0.75). There were no significant differences either in survival and freedom from nonfatal myocardial infarction, whether stratified on presence of heart failure, age, hypertension, or number of vessels diseased. Thus, 10-year follow-up results confirm earlier reports from CASS that patients with left ventricular dysfunction exhibit long-term benefit from an initial strategy of surgical treatment. Patients with mild stable angina and normal left ventricular function randomized to initial medical treatment (with an option for later surgery if symptoms progress) have survival equivalent to those patients randomized to initial surgery.

Coronary Artery Bypass↗

Progressive coronary luminal narrowing after cardiac transplantation.

Accelerated coronary disease is a major factor limiting long-term survival in cardiac transplant recipients. Coronary angiography was obtained a mean of 5.1 weeks posttransplantation and annually thereafter. Replicate projections recorded after nitroglycerine administration were quantitated using computer-assisted edge detection. Five hundred and fifteen coronary segments in 25 patients having 1-year follow-up and 353 segments in 18 patients reaching 2-year follow-up were compared with baseline angiograms. Significant change was defined as +/- 0.10 mm, equal to 3.8% change in diameter based on three standard deviations obtained from estimation of measurement error. Mean coronary diameter fell from 2.44 +/- 0.26 mm at baseline to 2.21 +/- 0.34 mm (p less than 0.001) at 1-year follow-up. This rate of diameter decline was 20-fold more rapid during the initial posttransplantation year than the rate of change of visually normal segments in nontransplant patients with coronary atherosclerosis elsewhere. There was no significant drop in mean diameter between the first and second year in those patients who had second-year studies. Decrease in absolute diameter for vessels greater than 2.9 mm significantly exceeded diameter reduction for smaller vessels but did not differ when considered as a ratio of vessel diameter. In 21 of 25 patients, mean coronary diameter reduction exceeded the three-standard deviation threshold at their last angiogram, but only two of these patients had visually detectable transplant coronary disease.

Cineangiography↗

Angiographic implications of cardiac transplantation.

Coronary vascular disease in the cardiac transplant recipient has become the third most frequent cause of death or retransplantation after infection and acute rejection. A unique pattern of concentric fibrointimal thickening develops within 1 year of cardiac transplantation; however, it is relatively inapparent on routine arteriography. The disease progresses primarily in distal vasculature, leading to progressive occlusion. Angiographically discrete lesions associated microscopically with advanced atherosclerotic plaques frequently occur in the more proximal vessels often associated with thrombus. The number of rejection episodes is somewhat predictive of the development of transplant coronary disease. Annual arteriograms performed in cardiac transplant recipients have revealed several distinctive angiographic features that include clockwise rotation of the heart, presence of coronary arterial-cameral fistulae, presumably resulting from right ventricular endomyocardial biopsy specimens and collateralization of the brachial anastomosis from coronary atrial branches. It is concluded that serial angiography in cardiac transplant recipients is important in the early detection of progressive graft atherosclerosis, a process that is clinically silent until such time as overt heart failure or cardiogenic shock occurs.

Coronary Angiography↗