PubMed Health⌕ Search

Biomedical subjects

E L Chan

Publications and source records attributed to E L Chan.

At least 19 recordsLinked to original sources

AU binding proteins recruit the exosome to degrade ARE-containing mRNAs.

Inherently unstable mammalian mRNAs contain AU-rich elements (AREs) within their 3' untranslated regions. Although found 15 years ago, the mechanism by which AREs dictate rapid mRNA decay is not clear. In yeast, 3'-to-5' mRNA degradation is mediated by the exosome, a multisubunit particle. We have purified and characterized the human exosome by mass spectrometry and found its composition to be similar to its yeast counterpart. Using a cell-free RNA decay system, we demonstrate that the mammalian exosome is required for rapid degradation of ARE-containing RNAs but not for poly(A) shortening. The mammalian exosome does not recognize ARE-containing RNAs on its own. ARE recognition requires certain ARE binding proteins that can interact with the exosome and recruit it to unstable RNAs, thereby promoting their rapid degradation.

3' Untranslated Regions↗

Human coronary endothelial cell activation by endotoxin is characterized by NF-kappa B activation and TNF-alpha synthesis.

Tumor necrosis factor-alpha (TNF-alpha), an early inflammatory mediator typically regulated by nuclear factor kappa B (NF-kappa B), plays a critical role in the development of cardiovascular dysfunction in sepsis. While several myocardial cell types synthesize TNF-alpha, the importance of the myocardial endothelium in sepsis-related cardiac cytokine production is unclear. To determine the role of the human coronary artery endothelial cell (HCA-EC) in the cytokine response to endotoxin we measured in vitro TNF-alpha synthesis, TNF-alpha mRNA, and the associated NF-kappa B response to LPS. To determine the magnitude of the HCA-EC response we assessed the TNF-alpha and NF-kappa B response to LPS in a human monocytic cell line (THP-1) as well. We observed an increase in supernatant TNF-alpha from LPS-stimulated HCA-EC (12 h) that was ablated by the proteosome inhibitor, ALLN (N-acetyl-Leu-Leu-norleucinal). Similarly, ALLN-sensitive TNF-alpha was produced by monocytes following LPS, although at concentrations 100-fold higher than HCA-EC. TNF-alpha mRNA from HCA-EC was detected at 60 min in LPS-stimulated cells, but not in unstimulated cells or cells pretreated with ALLN. NF-kappa B p50/p65 subunits were detectable in endothelial nuclear protein 60 min following LPS. In contrast, NF-kappa B subunits from monocytes were detected at 15 min. Also, while ALLN only attenuated endothelial NF-kappa B translocation, monocyte NF-kappa B translocation was completely inhibited. These data suggest endotoxin-stimulated human coronary endothelial cells express TNF-alpha, which is regulated in part by NF-kappa B activation, in a manner and degree distinct from human monocytes.

Cell Nucleus↗

Comparison of Chemicon SimulFluor direct fluorescent antibody staining with cell culture and shell vial direct immunoperoxidase staining for detection of herpes simplex virus and with cytospin direct immunofluorescence staining for detection of varicella-zoster virus.

A new rapid direct immunofluorescence assay, the SimulFluor direct fluorescent-antibody (DFA) assay, which can simultaneously detect herpes simplex virus types 1 and 2 (HSV-1 and -2) and varicella-zoster virus (VZV), was evaluated in comparison with our current standard procedures of (i) shell vial direct immunoperoxidase (shell vial IP) staining and cell culture for detection of HSV and (ii) cytospin DFA staining for VZV detection. A total of 517 vesicular, oral, genital, and skin lesion specimens were tested by all three procedures. For HSV detection, the SimulFluor DFA assay had an overall sensitivity, specificity, positive predictive value, and negative predictive value of 80.0, 98.3, 92.3, and 95.1%, respectively, when compared to culture. Shell vial IP staining had a sensitivity, specificity, positive predictive value, and negative predictive value of 87.6, 100, 100, and 96.9%, respectively, when compared with cell culture. The SimulFluor DFA assay, however, offers same-day, 1.5-hours results versus a 1- to 2-day wait for shell vial IP staining results and a 1- to 6-day wait for culture results for HSV. For VZV detection SimulFluor DFA staining detected 27 positive specimens as compared to 31 by our standard cytospin DFA technique--a correlation of 87.1%. A positive SimulFluor reaction for VZV is indicated by yellow-gold fluorescence compared to the bright apple-green fluorescence observed by cytospin DFA staining. There is no difference in turnaround time between the two assays. The SimulFluor DFA assay is a rapid immunofluorescence assay that can detect 80% of the HSV-positive specimens and 87% of the VZV-positive specimens with a 1.5-h turnaround time.

Animals↗

Evidence for the direct role of acetylcholinesterase in neurite outgrowth in primary dorsal root ganglion neurons.

Dorsal root ganglion (DRG) neurons show a transient peak expression of acetylcholinesterase (AChE) during periods of axonal outgrowth prior to synaptogenesis, suggesting that AChE has a non-enzymatic role during development. We have previously shown that perturbation of cell surface AChE in cultured embryonic rat DRG neurons results in decreased neurite outgrowth and neurite detachment. In this report, we demonstrate a direct correlation between endogenous AChE content and neurite outgrowth in primary DRG neurons. Adenoviral vectors were constructed using full-length rat AChE(T) cDNA in either the sense or antisense orientations to overexpress or knock down AChE expression, respectively. Treatment with the sense-expressing vector produced a 2.5-fold increase in AChE expression and a 2-fold increase in neurite length compared with either untreated or null virus-treated control cells. Conversely, treatment with the antisense-expressing vector reduced AChE expression by 40% and resulted in a reduction in neurite length of similar magnitude. We also observed that overexpression of AChE resulted in greater branching at the distal tips of each primary neurite as well as an increase in cell body size. These findings further indicate that AChE expressed on the axonal surface of developing DRG neurons may modulate their adhesive properties and thereby support axonal development.

Acetylcholinesterase↗

Evaluation of fluorescence-based amplified fragment length polymorphism analysis for molecular typing in hospital epidemiology: comparison with pulsed-field gel electrophoresis for typing strains of vancomycin-resistant Enterococcus faecium.

Fluorescence-based amplified fragment length polymorphism (fbAFLP) is a novel assay based on the fluorescent analysis of an amplified subset of restriction fragments. The fbAFLP assay involves the selective PCR amplification of restriction fragments from a total digest of genomic DNA. The ligation of adapters with primer-specific sites coupled with primers containing selective nucleotides allowed the full potential of PCR to be realized while maintaining the advantages of restriction endonuclease analysis. Fluorescence-based fragment analysis with polyacrylamide gel electrophoresis provides the accurate band sizing required for homology assessment. The large number of phylogenetically informative characters obtained by fbAFLP is well suited for cluster analysis and database development. The method demonstrated excellent reproducibility and ease of performance and interpretation. We typed 30 epidemiologically well-characterized isolates of vancomycin-resistant enterococci from an outbreak in a university hospital by fbAFLP. Clustering of fbAFLP data matched epidemiological, microbiological, and pulsed-field gel electrophoresis data. This study demonstrates the unprecedented utility of fbAFLP for epidemiological investigation. Future developments in standardization and automation will set fbAFLP as the "gold standard" for molecular typing in epidemiology.

Bacterial Typing Techniques↗

Comparison of the effectiveness of polymerase chain reaction and enzyme immunoassay in detecting Chlamydia trachomatis in different female genitourinary specimens.

BACKGROUND: In high-volume laboratories, enzyme immunoassay (EIA) is the most commonly used method of detecting Chlamydia trachomatis. The optimal specimen for detecting C trachomatis is a combined urethral and cervical swab. OBJECTIVE: To compare EIA with the combined urethral and cervical swab with polymerase chain reaction (PCR) on urine alone and urine mixed with cervical cells. PATIENTS AND METHODS: Phase 1 of the study included 752 sets of specimens used for comparison. In phase 2, another 212 samples of urine and urine plus cervical cells were added to the study for comparison of the 2 specimen types using PCR. RESULTS: In phase 1, 648 samples were negative and 76 were positive by all 3 methods and specimen combinations. Enzyme immunoassay was able to detect 81 positive samples (10.8%), whereas PCR on urine alone detected 97 positive samples (12.9%) and PCR on urine plus cervical cells detected 102 positive samples (13.6%), giving a sensitivity of 75%, 93.3%, and 98. 1% respectively. In phase 2, PCR on urine alone detected 119 positive samples (12.3%) and PCR on urine plus cervical cells detected 127 positive samples (13.1%), with a sensitivity of 92.2% and 98.5%, respectively. CONCLUSION: Polymerase chain reaction on urine alone or urine plus cervical cells is superior to EIA on combined cervical and urethral swabs. There is a slight advantage of adding cervical cells to the urine compared with the urine specimen alone when PCR is used as the assay for detection. The total inhibition rate in our female population is only 3.1% when PCR is used.

Cervix Uteri↗

Performance characteristics of the Becton Dickinson ProbeTec System for direct detection of Chlamydia trachomatis and Neisseria gonorrhoeae in male and female urine specimens in comparison with the Roche Cobas System.

OBJECTIVE: The Becton Dickinson BDProbeTec ET System is a new semiautomated system using strand displacement amplification technology that simultaneously amplifies and detects Chlamydia trachomatis and Neisseria gonorrhoeae DNA. The strand displacement amplification products are hybridized with a fluorescent detector probe and are captured by a chemiluminescent assay in a microwell format. An amplification control is also included to monitor assay inhibition. This study evaluated the performance of the BDProbTec ET system in detecting C trachomatis and N gonorrhoeae in male and female urine specimens, calculated its ability to process large volumes of specimens, and determined the inhibition rate. MATERIALS AND METHODS: Eight hundred twenty-five male and 399 female urine specimens were tested for both C trachomatis and N gonorrhoeae with the BDProbeTec ET system, and results were compared with those of the Roche Amplicor Cobas system. All urine specimens were processed on both assays on the same day they were received, according to the manufacturers' instructions. Discrepant results were resolved by in-house polymerase chain reaction assays. Internal or amplification controls were also used in each specimen assay to monitor inhibition. The throughput of the BDProbTec ET system was further tested with 150 urine specimens on an 8-hour shift for 2 days. RESULTS: The overall sensitivity, specificity, positive predicative value, and negative predicative value for for detection of chlamydia were 95.3%, 99.3%, 95.9%, and 99.2% for strand displacement amplification and 95.9%, 98.3%, 90.6%, and 99.3% for the Roche Amplicor system. For detection of gonorrhea, these values were 100%, 99.7%, 88.2%, and 100% and 96.7%, 98.9%, 69%, and 99.9%, respectively. The overall inhibition rates for both strand displacement amplification and Roche Amplicor were less than 3.5%. The BDProbTec ET system was able to produce 150 results each for chlamydia and gonorrhea and the internal control within the 8-hour shift. CONCLUSIONS: The performance characteristics of the BDProbeTec ET assay are similar to those of the Roche Amplicor polymerase chain reaction for detection of chlamydia and gonorrhea in male and female urine specimens. The system was able to produce 300 results in an 8-hour shift.

Chlamydia trachomatis↗

Minimal inhibitory effect of male urine on detection of Chlamydia trachomatis by Roche Amplicor PCR.

A total of 1120 specimens of fresh urine from male patients was tested for Chlamydia trachomatis with the Roche Amplicor PCR Kit and an in-house PCR assay. The in-house PCR had an internal control to monitor inhibitory effects of clinical specimens on the PCR assay. All urine samples were processed within 24-48 h of collection and DNA was extracted on the same day that the assays were performed. Specimens that gave discrepant PCR results were tested by a reference laboratory with both the Roche Amplicor kit and their in-house PCR assay. Of the 1120 samples, 174 gave positive results in both assays and 942 gave negative results in both assays. Only one specimen showed an inhibitory effect on the in-house PCR assays, as indicated by failure to produce the internal control PCR product. This specimen gave negative results by both assays. There were four discrepant results in the two PCR assays. One was a false negative result obtained with the Roche Amplicor kit and the remaining three discrepant results could not be resolved because there was an insufficient quantity of specimen. This study demonstrated that the Roche Amplicor kit could effectively detect C. trachomatis in urine specimens from this population of male patients with negligible inhibition of PCR.

Bacteriuria↗

Calcium metabolism and bone calcium content in normal and oophorectomized rats consuming various levels of saline for 12 months.

The effect of different intakes of salt for 12 mo on bone calcium content and urinary excretion of calcium and hydroxyproline were examined in sham operated and oophorectomized (OX) rats to determine the long term effects of high sodium intake and its interaction with estrogen deficiency. Sham operated (n = 24) and OX (n = 24) rats were divided into groups of six rats in a 2 x 4 design. One group of sham and one of OX rats were given 0, 2, 6 or 18 g/L sodium chloride to drink. Urine samples were collected at 0, 2, 4, 6, 10 and 12 mo for the measurement of sodium, calcium, creatinine and hydroxyproline. At the end of 12 mo, blood was taken for measurement of calcium, albumin, alkaline phosphatase and creatinine and the left femur was removed and analyzed for calcium and phosphate. Body weights of the OX rats were higher than the sham operated controls. At the start of the experiment (10 d after OX) urinary excretions of calcium and hydroxyproline were significantly higher in OX rats. However, after 4-6 mo, they were significantly lower in OX rats. Calcium excretion and hydroxyproline excretion were increased by high salt intake, and there was a significant correlation between sodium and calcium excretion (r = 0.962). Bone calcium content of OX rats was lower than their corresponding sham-operated controls. Sodium intake also had a significant effect on bone calcium content. Multiple regression analysis showed that OX and sodium intake explained 7.6% and 1.5% of the variation in bone calcium content. We conclude that high sodium intake causes increased loss of calcium and reduces bone calcium content in sham-operated as well as OX rats.

Administration, Oral↗

Suppression of experimental allergic encephalomyelitis in the Lewis rat, by administration of an acylated synthetic peptide of myelin basic protein.

A Myelin Basic Protein (MBP) epitope encephalitogenic for the Lewis rat (amino acid residues 68-86) was synthesized and acylated by the attachment of a palmitoyl residue. Lewis rats treated intravenously (i.v.) with the palmitoylated peptide alone were better protected against clinical manifestations of experimental allergic encephalomyelitis (EAE) than rats treated with the peptide inserted into liposomes or with the native peptide at similar doses. The administration of the acylated peptide (PAL68 86) conferred excellent protection against a challenge with the encephalitogenic peptide (p68-86) or with the intact MBP molecule, both before and after induction of active disease, and also when administered to recipients after the transfer of lymphocytes from MBP-challenged donors. Histological manifestations were also reduced to a statistically significant degree. Treatment with a palmitoylated peptide from a non-encephalitogenic region of the MBP molecule (PAL44-62) or with a palmitoylated unrelated peptide were ineffective. In vitro Ag-specific proliferative responses as well as the ability to transfer disease to syngeneic recipients, by lymph node lymphocytes from PAL68-86-treated donors, were considerably reduced. Addition of IL-2 to these cultures failed to restore either Ag-specific responsiveness or the ability of the cells to transfer disease. The results suggest that the administration of acylated peptides induces a profound state of unresponsiveness, and thus may provide an effective means for treating T cell-mediated autoimmune inflammatory disorders.

Acylation↗

Comparison of the Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay with the original standard assay and cell culture.

The new Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay was evaluated by comparison with the original standard assay and cell culture. A total of 853 paired male and female genital tract specimens was tested with both Sanofi Chlamydia Microplate EIA shortened and standard assays and the results were compared with those of cell culture. For confirmation, a blocking assay run in the shortened format was used. Discrepancies between the three methods were resolved by a direct fluorescent antibody (DFA) test on the EIA samples or the culture retentate, or both. After resolution of discrepant results, the standard assay had a sensitivity, specificity, positive predictive value and negative predictive value of 98.5%, 100%, 100% and 99.9%, respectively. The shortened assay results were 100%, 100%, 100% and 100%, respectively. The shortened assay takes approximately 1.5 h less time than the standard assay and this study demonstrated that they have equivalent sensitivity and specificity. The improvement in turnaround time enables results to be reported on the same day.

Cells, Cultured↗

A comparison of the Genie and western blot assays in confirmatory testing for HIV-1 antibody.

The Genie HIV-1/2 kit (Sanofi Diagnostics Pasteur, Montreal, Quebec), a synthetic-peptide solid-phase enzyme immunoassay, was evaluated as a confirmatory assay for HIV-1 antibodies in comparison with Western blot (BioRad, Hercules, CA, USA) on 50 stored HIV-1 antibody-positive sera and the 137 sera yielding repeated positive results in the conventional EIA screen out of 13405 fresh patient sera from Saskatchewan in 1993. The stored HIV-1-positive sera were uniformly positive in the Genie test. Of the 137 EIA screen-positive sera, 33 were uniformly positive and 64 were uniformly negative in Genie and Western blot; 36 were Genie-negative and indeterminate by Western blot; and four were Genie indeterminate, of which one was negative and three were indeterminate by Western blot. All HIV-1 Western blot-indeterminate and Genie-interdeterminate sera were negative in radio-immunoprecipitation assay (RIPA) and Western blot for HIV-1 and HIV-2 antibodies performed by a reference laboratory. Genie gave an accurate definitive result for 97% of EIA positive sera compared with 71% for Western blot. There was excellent correlation between Genie, Western blot and RIPA results. However, the Genie assay was faster, less costly and yielded fewer indeterminate results than Western blot in confirmatory testing for HIV-1 antibodies.

Blotting, Western↗

Evaluation of Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay and comparison with cell culture and Syva Chlamydia MicroTrak II EIA in high- and low-risk populations.

Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol and the Syva (San Jose, Calif.) MicroTrak II EIA, and the results were compared with those obtained by cell culture. For the analysis of samples from female patients, the patients were divided into high- and low-risk categories. An additional 121 male urethral samples were collected and tested by the Sanofi Microplate EIA and cell culture; for the analysis of samples from male patients, the patients were divided into asymptomatic and symptomatic categories. All specimens positive by enzyme immunoassay (EIA) were confirmed by a blocking assay following the respective manufacturer's instructions. Specimens negative by EIA that fell within a gray zone 30% below the cutoff and negative cultures with one or more corresponding positive EIA results were tested further by cytocentrifugation and direct immunofluorescent assay. The overall sensitivity, specificity, positive predictive value, and negative predictive value for Syva versus culture were 94, 98.8, 85.5 and 99.6%, respectively. After resolution, the results were 94.5, 99.6, 94.5, and 99.6%, respectively. The parallel results for the Sanofi Microplate EIA versus culture were 94.0, 98.7, and 83.9, and 99.6%, respectively, and after being resolved, the results were 94.9, 100, 100, and 99.6%, respectively. In the small male population tested, the resolved results of the Sanofi Microplate EIA versus culture demonstrated sensitivity, specificity, positive predictive value, and negative predictive value of 100, 100, 100, and 100%, respectively. The present study demonstrated that the Sanofi Microplate EIA shortened protocol is highly sensitive and specific in comparison with cell culture and the Syva MicroTrak II EIA.

Age Factors↗

Oligodendroglial cyclic AMP response element-binding protein: a member of the CREB family of transcription factors.

Several laboratories have shown that cyclic AMP (cAMP) plays an important role in inducing oligodendrocyte differentiation and myelin synthesis. Our previous results have shown that oligodendrocytes contain a nuclear protein that binds to the DNA sequence TGACGTCA or cAMP response element (CRE) known to be involved in the transcriptional regulation of cAMP-responsive genes. In this report the oligodendroglial CRE-binding protein was further identified by using two different antibodies which specifically recognize the CRE-binding protein known as CREB. In DNA-shift assays CREB-1(X-12) antibody interacted with the CRE-protein complexes resulting in further retardation ("super shift") of the mobility of the bands in the gels. Immunoprecipitation of oligodendroglial nuclear extracts with CREB(240) antibody prior to the DNA binding assays resulted in a lack of formation of CRE-protein complexes. In addition immunoreaction with CREB(240) antibody identified the CRE-binding species as a 45 kDa phosphoprotein. Immunocytochemical staining with CREB(240) antibody in oligodendrocytes from 10-, 14-, and 18-day-old and adult rats indicated that this protein is expressed before the appearance of myelin basic protein (MBP) which was used as a marker of myelin synthesis. Collectively, these observations support our previous results and indicate that the oligodendroglial CRE-binding protein species is highly homologous to the CREB protein. The developmental expression of this CREB protein supports the idea of a possible role during the early stages of oligodendrocyte differentiation preceding the peak of myelin synthesis in rat CNS.

Animals↗

The use of a confirmatory assay to increase the sensitivity and specificity of the Chlamydiazyme test.

The blocking assay was used to reexamine 15,662 patient specimens (2,565 male specimens, 13,097 female specimens) that were submitted for Chlamydia detection using the Chlamydiazyme EIA assay (Abbott Laboratories, North Chicago, IL). Specimens that gave optical density (OD) readings between 1.99 to cutoff and between cutoff to 3 times the negative control in the Chlamydiazyme EIA assay were analyzed further by the blocking assay during the phase 1 study. In the phase 2 study, another 1,120 specimens (473 male specimens and 647 female specimens) that had the above mentioned OD range in the Chlamydiazyme assay were tested with the blocking assay and the direct fluorescent antibody test using the cytospin method. Significant finding from phase 1 study demonstrated that 42.3% of the male specimens with optical density between cutoff to three times the negative control can be blocked by blocking assay (confirmed positive), whereas only 50% of the female specimens with OD range between cutoff to .5 were blocked by the blocking assay. In the phase 2 study, similar results were obtained with the blocking assay. The direct fluorescent antibody test showed excellent correlation with the blocking assay. These data showed that both blocking or direct fluorescent antibody tests can be used for confirmation purposes to increase the sensitivity and specificity of the assay. However, for specimens with OD values below the cutoff to 3 times the negative control, it was necessary to reassess the specimens by either of the methods. This was true especially with the male specimens.

Antibodies, Monoclonal↗

A 1-year evaluation of Syva MicroTrak Chlamydia enzyme immunoassay with selective confirmation by direct fluorescent-antibody assay in a high-volume laboratory.

TThe Syva MicroTrak Chlamydia enzyme immunoassay (EIA; Syva Company, San Jose, Calif.) with cytospin and direct fluorescent-antibody assay (DFA) confirmation was evaluated on 43,630 urogenital specimens over a 1-year period in the Provincial Laboratory in Regina, Saskatchewan, Canada. This was a two-phase study intended to define a testing algorithm for Chlamydia trachomatis that would be both highly accurate and cost-effective in our high-volume (> 3,000 tests per month) laboratory. The prevalence of C. trachomatis infection in our population is moderate (8 to 9%). In phase 1, we tested 6,022 male and female urogenital specimens by EIA. All specimens with optical densities above the cutoff value and those within 30% below the cutoff value were retested by DFA. This was 648 specimens (10.8% of the total). A total of 100% (211 of 211) of the specimens with optical densities equal to or greater than 1.00 absorbance unit (AU) above the cutoff value, 98.2% (175 of 178) of the specimens with optical densities of between 0.500 and 0.999 AU above the cutoff value, and 83% (167 of 201) of the specimens with optical densities within 0.499 AU above the cutoff value were confirmed to be positive. A total of 12% (7 of 58) of the specimens with optical densities within 30% below the cutoff value were positive by DFA. In phase 2, we tested 37,608 specimens (32,495 from females; 5,113 from males) by EIA. Only those specimens with optical densities of between 0.499 AU above and 30% below the cutoff value required confirmation on the basis of data from phase 1 of the study. This was 4.5% of all specimens tested. This decrease in the proportion of specimens requiring confirmation provides a significant cost savings to the laboratory. The testing algorithm gives us a 1-day turnaround time to the final confirmed test results. The MicroTrak EIA performed very well in both phases of the study, with a sensitivity, specificity, positive predictive value, and negative predictive value of 96.1, 99.1, 90.3, and 99.7%, respectively, in phase 2. We suggest that for laboratories that use EIA for Chlamydia testing, a study such as this one will identify an appropriate optical density range for confirmatory testing for samples from that particular population.

Algorithms↗

History of medicine and nephrology in Asia.

The beginning of Chinese medicine has been attributed to 3 mythical emperors who gathered herbs for medicines. During the 2nd century BC, Han dynasty physicians developed cranial trephining and sedation with wine and herbs for anesthesia. Chiang Chung-Ching (142-212 AD) used the appearance of rashes in diagnosis, treated infections with anthelmintics and asthma with ephedra, described the symptoms of diabetes mellitus and expanded medical ethics. The specialties of obstetrics, pediatrics, ophthalmology and dentistry were described in the records of the Han and Tang dynasties, and methods of setting fractures and treating trauma were comparable with those of Roman military doctors. Shen Tua (1031-1095 AD) compiled a pharmacopeia and studied acupuncture and the pulses. Forensic medicine was developed during the 10th century by Sung Tse, who also advocated hand washing with sulfur and vinegar to avoid infection during autopsies. The Daoist physicians used androgens and estrogens to treat hypogonadism with therapeutic preparations of placentas. They also had an advanced knowledge of alchemy, claiming to achieve 'immortality' by their preservation techniques. Qualifying examinations for physicians were conducted by the Chinese state as early as the 1st century AD, and later incorporated philosophy and art to conform with the Confucian ideal. Throughout these eras, Chinese medicine profited from contact with western Asia. In ancient Chinese medicine, the excretory function of the kidney was attributed to the bladder. 'Kidney weakness', which refers to somatized depression, was treated by acupuncture along the 'kidney channel'. Pulse examination was also used to give a measure of the imbalance of renal Yin and Yang.(ABSTRACT TRUNCATED AT 250 WORDS)

Alchemy↗