PubMed Health⌕ Search

Biomedical subjects

E L Yeh

Publications and source records attributed to E L Yeh.

At least 19 recordsLinked to original sources

Striatal kinetic modeling of FDOPA with a cerebellar-derived constraint on the distribution of volume of 30MFD: a PET investigation using non-human primates.

The peripherally born metabolite of FDOPA, 3-O-Methyl-FDOPA (3OMFD), crosses the blood-brain barrier, thus complicating positron emission tomography-FDOPA (PET-FDOPA) data analysis. In previous reports the distribution volume (DV) of 3OMFD was constrained to unity. We have recently shown that the forward transport rate-constant of FDOPA (K(S1)) and the cerebellum-to-plasma ratio (C(b)/C(p)), a measure for the DV of 3OMFD, are functions of plasma large neutral amino acid (LNAA) concentration. Given large interstudy and intersubject differences in plasma LNAA levels, variations in the DV of 3OMFD are significant. In this report, the authors propose a constraint on the DV of 3OMFD that accounts for these variations. Dynamic PET-FDOPA scans were performed on 12 squirrel monkeys and 12 vervet monkeys. Two sets of constraints were employed on the compartmental model--M1 or M2. In M1, the striatal DV of 3OMFD was constrained to unity; in M2, the striatal DV of 3OMFD was constrained to an estimate derived from the cerebellum. Striatal and cerebellar time-activity curves were fitted using FDOPA and 3OMFD plasma input functions. The estimate of K(S1) and that of the compartmental FDOPA uptake-constant (K(i)), both obtained using M2, were adjusted to values corresponding to average LNAA levels. Finally, K(i) was compared with the graphical uptake-constant (PK(j)). With the use of constraint M2, intersubject variability of squirrel monkey k(S3) and K(i) was reduced by 45% and 53%, respectively; and for vervet monkeys, by 54% and 44%, respectively. Intersubject variability of K(1) and K(i) was further reduced after correction for variations in intersubject plasma LNAA levels (for squirrel monkeys, by 67% and 41%; for vervet monkeys, by 40% and 36%, respectively). K(i) correlation to PK(i) was enhanced to identity. Finally, average cerebellar k(C2) estimates were more than 2.5-fold higher than striatal k(S2) estimates (P < 0.0001). In modeling of PET-FDOPA data, it cannot be assumed that the DV of 3OMFD is unity. The cerebellar-derived constraint furnishes a reliable estimate for the DV of 3OMFD. Invoking the constraint and correcting for variations in plasma LNAA significantly reduced interstudy and intersubject variations in parameter estimates.

Animals↗

Gallium-67 uptake in non-malignant stomach.

Although 67Ga imaging has been widely used in the diagnosis of malignant and inflammatory diseases, its uptake in the stomach has been reported in the literature mainly in gastric lymphoma and carcinoma. As shown by this report, intense gastric uptake of the radionuclide may be seen not only in malignancy, but also in gastritis, and even in the stomach without known disease. Perhaps, the benign gastric uptake of 67Ga deserves more emphasis in the literature. Our findings would suggest that gastroscopy and biopsy are not necessarily indicated solely because of the gastric concentration of 67Ga.

Aged↗

Gastric gallium-67 uptake in gastritis.

Even though Ga-67 imaging has been used widely in the diagnosis of malignant as well as inflammatory lesions, its uptake in the stomach has been reported in the literature mainly in gastric lymphoma and carcinoma. As shown in this case, intense gastric uptake of the radionuclide may be seen in common gastritis without malignancy. Perhaps the benign gastric uptake of Ga-67 deserves more emphasis.

Adult↗

Compton scatter image simulating jugular venous reflux.

In a radionuclide cerebral angiographic study, Tc-99m photons from the subclavian vein may scatter in the superficial tissues of the neck and head, resulting in an image simulating the jugular venous reflux. In a scintillation camera peaked at 140 keV with a 20% window, any scattered photons with a scatter angle of less tha 53.5 degrees may be counted in the Tc-99m window. This scatter angle is large enough to allow counting of many secondary photons from Compton collisions in an area quite distant from the radioactive source to be counted, provided the scatter area and source are separated by air.

Brain↗

Theoretical error in radionuclide ejection fraction study due to photon attenuation.

The ejection fractions measured with the radionuclide method are usually lower than those measured with the X-ray contrast method in our hospitals. One of the reasons for this may be that the photon attenuation by the cardiac blood pool and soft tissue is greater for the larger end-diastolic ventricle than that for the end-systolic ventricle. Mathematically, the error due to photon attenuation in radionuclide ejection fraction study is calculated to be about 5 percentage points. Clinically, if 5 percentage points are added to the ejection fractions measured by the radionuclide method, the results would correlate better with the studies by the X-ray contrast method. The correction factors for photon attenuation may also be applied in calculation of the residual urinary bladder volume.

Cardiac Output↗

Incidental detection of pericardial effusions on abdominal ultrasound studies.

During ultrasounc studies of the abdomen, three cases of pericardial effusion, two proven and one presumptive, were detected as incidental findings. Pericardial effusion was not clinically suspected at the time of study. Study of the heart-liver interface is simple and can be done in routine abdominal ultrasound study. The pericardial effusion can also be aspirated through a B-mode aspiration transducer.

Abdomen↗

Technical considerations in B-mode scanning with an aspiration transducer.

Proper orientation of the B-mode ultrasonic aspiration transducer is important for accurate imaging during aspiration biopsy. The transducer extension axis must be perpendicular to the plane of the scanning arm for accurate representation of reflector locations. Single pass scans without compound angulation of the transducer are recommended when perpendicularity is not absolute. A simple adaptor to maintain perpendicularity is described.

Biopsy, Needle↗

Varying ejection fractions of both ventricles in paradoxical pulses: demonstration by radionuclide study.

A noninvasive radionuclide study of the paradoxical pulse in pericardial effusion is described. The study shows complementary changes of the right and left ventricular ejection fractions in a patient with paradoxical pulse, supporting the theory that the inspiratory reduction of the left ventricular stroke volume is an immediate and direct result of the inspiratory increase of the right ventricular filling. The technique may be sensitive to detect early paradoxical pulse and cardiac tamponade.

Adult↗

Quantitative methods in the evaluation of thallium-201 myocardial perfusion images.

Methods have been developed for on-line computer enhancement of a scintillation camera's myocardial images and for a graphical presentation showing relative thallium-201 activity in the myocardium. Enhancement uses fast Fourier transform techniques. The methods have been applied to multiple images obtained after stress and 4--5 hr rest. Patients with myocardial infarction and/or transient ischemia were evaluated and typical examples are presented.

Computers↗

Reverberations in echocardiograms.

Different types of reverberations which may cause confusing artifacts in echocardiograms are described. Reverations between the targets may result in identifiable complex echo patterns. An echocardiogram with reverberating echoes is presented. Several experimental studies were done to explain the reverbating echoes. The reverberating echoes may be more prominently displayed than the primary echoes. This raises the possibility of obtaining useful information from the reverberating echoes.

Adolescent↗

Pulsed Doppler studies in B-mode ultrasound scanning.

In B-mode ultrasound abdominal studies, vascular structures may be confused with other tissues. A pulsed Doppler unit was coupled to a B-mode scanner by attaching the Doppler transducer to the B-mode transducer. A standardization procedure was designed to assure that the ultrasound beams from the 2 transducers were properly aligned, and that the Doppler focusing was accurate. The Doppler signal may be obtained from any point in the B-mode image in order to differentiate vascular structure from other tissue types.

Abdomen↗

Jugular venous reflux in cerebral radionuclide angiography.

Jugular venous reflux was observed in six routine cerebral radionuclide angiograms. Repeat studies during a Valsalva maneuver failed to reproduce the reflux. In one case the reflux appeared to be related to the arm position; but in the other five cases, the cause remains unknown. Such reflux may be mistaken for superior vena cava syndrome or asymmetric carotid blood flow.

Cerebral Angiography↗