Time-domain and spectral-domain optical coherence tomography in the analysis of brain tumor tissue.

INTRODUCTION: Detection of residual tumor during resection of glial brain tumors remains a challenge because of a low inherent contrast of adjacent edematous brain, the surrounding infiltration zone, and the solid tumor. Therefore, new technologies that may facilitate an intraoperative analysis of the tissue at the resection edge are of great interest to neurosurgeons. MATERIALS AND METHODS: For ex vivo imaging of gliomas in a mouse model and human biopsy specimens of brain tumors and nervous system tissue we have used a time-domain Sirius 713 Tomograph with a central wavelength of 1,310 nm and a coherence length of 15 microm equipped with a mono mode fiber and a modified optical coherence tomography (OCT) adapter containing a lens system for imaging at a working distance of 2.5 cm. A spectral-domain tomograph using 840 nm and 930 nm superluminescence diodes (SLD) with a central wavelength of 900 nm was used as a second imaging modelity. RESULTS: Both time-domain and spectral-domain coherence tomography delineated normal brain, the infiltration zone and solid tumor in murine intracerebral gliomas. Histological evaluation of H&E sections parallel to the optical plain demonstrated that tumor areas of less than a millimeter could be detected and that not only solid tumor, but also brain invaded by a low-density single tumor cells produced an OCT signal different from normal brain. Spectral-domain OCT (SD-OCT) demonstrated a significantly more detailed microstructure of tumor and normal brain up to a tissue depth of 1.5-2.0 mm, whereas the interpretation of time-domain OCT (TD-OCT) was difficult at a tissue depth >1.0 mm. Because of rapid scanning times SD-OCT data could be acquired as 3D data maps, which allowed a multi-planar analysis of the tumor to brain interface. Similar to our findings in experimental gliomas, images of human nervous system tissue acquired using SD-OCT showed a characteristic signal of normal brain tissue and a detailed microstructure of tumor parenchyma. CONCLUSION: Spectral-domain OCT of experimental gliomas and human brain tumor specimens differentiates solid tumor, diffusely invaded brain tissue, and adjacent normal brain based on microstructure and B-scan signal characteristics. In conjunction with the rapid image acquisition rates of SD-OCT, this technology carries the potential of a novel intraoperative imaging tool for the detection of residual tumor and guidance of neurosurgical tumor resections.

Animals↗

[Utilizing optical coherence tomography (OCT) for visualization of urothelial diseases of the urinary bladder].

PURPOSE: The technique of optical coherence tomography (OCT) has significantly improved over the last few years. This new diagnostic procedure allows imaging of tissue structure of the bladder wall during cystoscopy with high resolution. MATERIALS AND METHODS: The penetration depth of OCT is limited to 2.5 mm. The resolution is approximately 15 microm. Fifty patients with different clinical conditions of the bladder were examined. Altogether 488 OCT images were generated. RESULTS: OCT of normal bladder mucosa clearly shows a differentiation between urothelium, lamina propria, and smooth muscle. Cystitis and metaplasia are characterized by blurring of the laminated structure and thickening of the epithelial layer. In malignant areas there is complete loss of the regular layered tissue structure. CONCLUSION: OCT improves the diagnosis of flat lesions of the urothelium. It has the potential for facilitating intraoperative staging of malignant areas in the bladder.

Aged↗

Optical coherence tomography for experimental neuroendoscopy.

Optical coherence tomography (OCT) is a non-invasive and non-contact imaging technology that has been applied to several biomedical applications. We have recently demonstrated that OCT allows discrimination of tumor adjacent brain, diffuse and solid tumor tissue and that this technology may be used to detect residual tumor within the resection cavity during resection of intrinsic brain tumors. Here we show that an OCT integrated endoscope can image the endoventricular anatomy and other endoscopically accessible structures in a human brain specimen. A Sirius 713 optical coherence tomography device was mounted to a modified rigid endoscope. A formalin-fixed human brain specimen was used to simulate endoscopic visualization of brain anatomy and two specimens of fixed malignant tumors with endoventricular growth patterns. Simultaneous OCT imaging and endoscopic video imaging of the visible spectrum was possible using a graded index rod endoscope. OCT imaging of a human brain specimen in water allowed an in-depth view into structures like the walls of the ventricular system, the choroid plexus or the thalamostriatal vein. OCT further allowed imaging of structures beyond tissue barriers or opaque media. In this fixed specimen OCT allowed discrimination of vascular structures down to a diameter of 50 mum. In vessels larger that 100 mum the lumen could be discriminated and within larger blood vessels a layered structure of the vascular wall as well as endovascular plaques could be visualized. This in vitro pilot study has demonstrated that OCT integrated into neuroendoscopes may add information that cannot be obtained by the video imaging alone. This technology may provide an extra margin of safety by providing cross-sectional images of tissue barriers within optically opaque conditions.

Brain↗

Changes in function and morphology of normal human skin: evaluation using optical coherence tomography.

BACKGROUND: Optical coherence tomography (OCT) is a noninvasive morphological method for investigating human skin. It allows high-resolution in vivo imaging of inflammatory skin diseases and tumours. Because it is a newly developed method, systematic studies on standardization and on evaluation of factors influencing the representation of the skin have not yet been performed. OBJECTIVES: In this study, normal human skin was treated with various external stimuli which induce changes of function and morphology. Changes in stratum corneum thickness as well as changes induced by pigmentation, oedema and erythema were investigated using OCT. METHODS: Healthy skin of human volunteers was treated with tape stripping, ultraviolet A irradiation, water, histamine, nicotinic acid and various ointments. RESULTS: In the tape stripping experiment, the thickness of the horny layer was quantified and monitored. Pigmentation increased the light attenuation of the tissue, whereas hydration and erythema led to a slight decrease of scattering. Topical treatment of the skin gave a nonspecific increase of penetration depth of the light due to the lower reflectivity of the surface. CONCLUSIONS: There are various physiological conditions which influence optical properties of the skin. These parameters should be considered when performing standardized OCT studies.

Adult↗

Isolation and characterization of indene bioconversion genes from Rhodococcus strain I24.

Rhodococcus strain 124 is able to convert indene into indandiol via the actions of at least two dioxygenase systems and a putative monooxygenase system. We have identified a cosmid clone from 124 genomic DNA that is able to confer the ability to convert indene to indandiol upon Rhodococcus erythropolis SQ1, a strain that normally can not convert or metabolize indene. HPLC analysis reveals that the transformed SQ1 strain produces cis-(1R,2S)-indandiol, suggesting that the cosmid clone encodes a naphthalenetype dioxygenase. DNA sequence analysis of a portion of this clone confirmed the presence of genes for the dioxygenase as well as genes encoding a dehydrogenase and putative aldolase. These genes will be useful for manipulating indene bioconversion in Rhodococcus strain 124.

Amino Acid Sequence↗

[Optical coherence tomography of the cornea and the anterior eye segment].

TARGET: The method of optical coherence tomography (OCT) was investigated regarding its suitability and limits for measuring the cornea and the anterior segment of the eye. Furthermore, the stromal expansion of thermally induced lesions in the cornea directly after irradiation was determined within the scope of the laser thermokeratoplasty (LTK). MATERIAL AND METHODS: With the experimental scanning OCT system, x-z sections of the anterior eye segment were made with an optical resolution of about 20 microns axially and 25 microns laterally. Freshly enucleated, tonicized porcine eyes were used as model eyes. Thermal lesions were applied with a continuously emitting laser diode (lambda = 1.86 microns) and various radiation parameters. Before and after coagulation, the cornea was viewed from limbus to limbus in a central OCT scan and the individual coagulation source was measured. RESULTS: Global and local changes of the thickness of the cornea as well as the distance between cornea and lens were measured with high precision. Thermal lesions in their expansion can be dearly presented and matching well with the histologically stained sections, but are not as exactly defined at the edges due to the limited optical resolution, as known from histological preparations. CONCLUSION: With the OCT method quantitative measuring of the anterior eye segment can be performed in vitro and with reduced resolutions also in vivo. Due to the qualitatively good correspondence regarding the dimensions of thermal damage of the cornea with histologically obtained morphometric results, this method can be used for supervision of coagulation directly after LTK as well as for examination of the individual healing process.

Animals↗

Optical coherence tomography of the human skin.

BACKGROUND: Optical coherence tomography (OCT) is a new diagnostic method for tissue characterization. OBJECTIVE: We investigated normal and pathologic structures in human skin in several locations to evaluate the potential application of this technique to dermatology. METHODS: Based on the principle of low-coherence interferometry, cross-sectional images of the human skin can be obtained in vivo with a high spatial resolution of about 15 microns. Within a penetration depth of 0.5 to 1.5 mm, structures of the stratum corneum, the living epidermis, and the papillary dermis can be distinguished. RESULTS: Different layers could be detected that were differentiated by induction of experimental blisters and by comparison with corresponding histologic sections. Furthermore, OCT images of several skin diseases and tumors were obtained. CONCLUSION: OCT is a promising new imaging method for visualization of morphologic changes of superficial layers of the human skin. It may be useful for noninvasive diagnosis of bullous skin diseases, skin tumors, and in vivo investigation of pharmacologic effects.

Adult↗