PubMed Health⌕ Search

Biomedical subjects

E Lesniewska

Publications and source records attributed to E Lesniewska.

At least 19 recordsLinked to original sources

Shear force microscopy with a nanoscale resolution.

This paper presents a shear force microscope having a nanometric resolution at high scan rates. Current techniques were reviewed and tested, and a design based on the use of a tuning fork is described. The use of a low quality factor enabled us to decrease the response time and increase the stability of the tracking. The microscope was coupled with a tunneling current detection, in order to study the interactions between the sample and the probe during scanning. As an example, a sharp nickel nanotip was used to image a gold surface, showing details down to a few nanometers, even at scanning rates of 4Hz.

Journal Article↗

Cell wall modification in grapevine cells in response to UV stress investigated by atomic force microscopy.

Despite cell wall reinforcement being a well-known defence mechanism of plants, it remains poorly characterized from a physical point of view. The objective of this work was to further describe this mechanism. Vitis vinifera cv Gamay cells were treated with UV-light (254 nm), a well-known elicitor of defence mechanisms in grapevines, and physical cell wall modifications were observed using the atomic force microscopy (AFM) under native conditions. The grapevine cell suspensions were continuously observed in their culture medium from 30 min to 24h after elicitation. In the beginning, cellulose fibrils covered by a matrix surrounded the control and treated cells. After 3 h, the elicited cells displayed sprouted expansions around the cell wall that correspond to pectin chains. These expansions were not observed on untreated grapevine cells. The AFM tip was used to determine the average surface elastic modulus of cell wall that account for cell wall mechanical properties. The elasticity is diminished in UV-treated cells. In a comparative study, grapevine cells showed the same decrease in cell wall elasticity when treated with a fungal biotic elicitor of defence response. These results demonstrate cell wall strengthening by UV stress.

Cell Wall↗

Observation of the posterior endothelial surface of the rabbit cornea using atomic force microscopy.

PURPOSE: To study the surface of normal corneal endothelium by means of atomic force microscopy (AFM). METHODS: The central corneal endothelial posterior surface of New Zealand white rabbits was examined. Specimens were observed in Balanced Salt Solution using the contact mode of the AFM either fresh or after fixation in cacodylate-buffered glutaraldehyde solution. Removal of sialic acid residues and hyaluronic acid was achieved by means of enzymatic treatment with neuraminidase and hyaluronidase. RESULTS: Observation of the fresh specimens revealed the presence of an apical endothelial surface coating material (glycocalyx). Removal of sialic acid residues and hyaluronic acid after enzymatic treatment using neuraminidase and hyaluronidase, respectively, permitted the elucidation of the structure of the nondigested coating material. Fixation of the samples resulted in removal of the surface coating material. The imaging of the fixed endothelium surface revealed the mosaic of polygonal cells with the apical flaps of cell junctions emerging over the cell surface. The cell shape and the other characteristics of the posterior surface fixed endothelium were comparable to those described in the literature using scanning electron microscopy. The scanning of very small ranges has provided high-resolution images at the nanometer level in fixed and fresh corneal endothelial surfaces. CONCLUSION: The atomic force microscope represents a new powerful imaging tool permitting high-resolution observation of corneal endothelium surface in fresh and minimally prepared fixed specimens.

Animals↗

Affinity scale between a carrier and a drug in DPI studied by atomic force microscopy.

The dry powder inhalers (DPIs) consist, in the most cases, of ordered mixture where the particles adhesion results of interactions between the drug and the carrier. Generally, one step of production process is the micronization of the drug particles in order to reduce the size for ordered mixing optimization. But this operation is known to partially create an amorphous surface. In this case, surrounding storage conditions, like relative humidity (RH), are able to modify the percentage of amorphous drug surface. The aim of this study was to investigate surface reactivity, surface energy and direct force measurements by atomic force microscopy (AFM) between lactose (carrier) and zanamivir (drug) crystals references in various conditions of RH. Secondly, an amorphization of the drug surface was induced by humidity relative treatment in order to evaluate the consequences of the transition from crystal to amorphous phase. The study demonstrated that the amorphization of drug surface induces an increase of drug affinity with the carrier surface. Ex situ and in situ amorphization of zanamivir tend to reach the affinity measured between raw materials: carrier and micronized drug particles. AFM allowed adhesion force discrimination between the different forms of the drug particles and demonstrated the potential for investigating adhesion properties in DPI formulation.

Drug Carriers↗

Dry powder inhaler: influence of humidity on topology and adhesion studied by AFM.

In the dry powder inhalers (DPIs), the adhesion results of the interactions between the active substance and the excipient. The carrier and the micronized drug particle morphologies are believed to affect the delivery of the drug. In this work, the couple studied was the lactose monohydrate and micronized zanamivir, used for the treatment of influenza. In a first approach, observations by scanning electron microscopy (SEM) have shown that the relative humidity (RH) greatly influenced the zanamivir amount fixed on the lactose monohydrate surface. This paper deals with the direct measurement in controlled atmosphere by atomic force microscopy (AFM) of the forces and the interaction ranges between a zanamivir probe and a lactose substrate. Selected zanamivir crystals were attached to the standard AFM probe. Different RH have been used in order to determine influent parameters permitting to identify the nature of adhesion forces between them. This study demonstrated that the increase of RH modified progressively the surface topology of the two components and increased the adhesion force.

Aerosols↗

Measuring magnetic susceptibilities of nanogram quantities of materials using microcantilevers.

We describe a novel technique for measuring magnetic susceptibilities of nanogram quantities of magnetic materials that utilizes the extreme force sensitivity of microcantilevers. The magnetic force acting on samples attached to the free end of a cantilever can be measured as changes in the resonance response of the cantilever. The shift in resonance frequency of the cantilever is proportional to the field gradient, whereas the deflection of a cantilever is proportional to the magnetic force. The magnetic susceptibility measurement is based on comparison of the forces acting on the sample and a reference material in the same magnetic field and field gradient. We have determined the magnetic susceptibilities of nanogram quantities of many paramagnetic materials. The measured magnetic susceptibilities show excellent agreement with values found in the literature.

Journal Article↗

Investigation by atomic force microscopy of forces at the origin of cement cohesion.

In cement paste, the cohesion results of the interactions between calcium silicate hydrate (CSH) surfaces in an interstitial ionic solution. (N, V, T) Monte Carlo simulations show that the interactions are due to the ion correlation forces influenced by the surface charge density, the ionic concentration and the ion valence. This paper deals with the direct measurement in solutions by atomic force microscopy (AFM) of the forces and the interaction ranges between a probe and an atomically smooth substrate covered by CSH nanoparticles. Different electrolytic solutions (Ca(OH)2, CaCl2, NaCl, NaOH) have been used in order to determine influent parameters permitting to identify the nature of acting forces. Investigations have been rendered possible by selecting appropriate experimental setup and solutions. The selected probe and substrate on which CSH nanoparticles have previously grown are neutral regarding the reactivity during experiments permitting the exchange of solutions. Results show that a force originates from electrostatic nature and differs from Derjaguin-Landau-Verwey-Overbeek (DLVO) theory. Agreement is found between experiments and (N,V,T) Monte Carlo simulations of ionic correlation forces. These forces are at the origin of the cohesion of cement paste.

Journal Article↗

In situ imaging of detergent-resistant membranes by atomic force microscopy.

Purified detergent-resistant membranes (DRMs) are powerful tools for the biochemical study of plasma membrane domains. To what extent these isolated DRMs correspond to native membrane domains remains, however, a matter of debate. The most immediate question to be answered concerns the in situ size range of DRMs, a determination that escapes classical microscopy techniques. In this study we show that in situ three-dimensional images of a material as fragile as Triton X-100-treated cells can be obtained, in buffer, by tapping mode atomic force microscopy. These images establish that, prior to the isolation procedure, the detergent plasma membrane fragments form domains whose size frequently exceeds 15-20 microm(2). This DRMs size range is about 1 order of magnitude higher than that estimated for the larger microdomains of living cells, which strongly suggests that membrane microdomains rearrange into larger DRMs during Triton X-100 treatment. Concomitantly, the images also reveal the presence of the cytoskeleton, which is resistant to detergent extraction, and suggest that, in situ, DRMs are associated with the membrane cytoskeleton.

Animals↗

Detection of peptide-lipid interactions in mixed monolayers, using isotherms, atomic force microscopy, and fourier transform infrared analyses.

To improve the understanding of the membrane uptake of an amphipathic and positively charged vector peptide, we studied the interactions of this peptide with different phospholipids, the nature of whose polar headgroups and physical states were varied. Three lipids were considered: dipalmitoylphosphatidylcholine (DPPC), dipalmitoylphosphatidylglycerol (DPPG), and dioleoylphosphatidylglycerol (DOPG). The approach was carried out by three complementary methods: compression isotherms of monolayers and atomic force microscopy observations associated with Fourier transform infrared investigations. From analysis of the compression isotherms, it was concluded that the peptide interacts with all lipids and with an expansion of the mean molecular area, implying that both components form nonideal mixtures. The expansion was larger in the case of DOPG than for DPPC and DPPG because of an alpha to beta conformational transition with an increase in the peptide molar fraction. Atomic force microscopy observations showed that the presence of small amounts of peptide led to the appearance of bowl-like particles and that an increase in the peptide amounts generated the formation of filaments. In the case of DOPG, filaments were found at higher peptide molar fractions than already observed for DOPC because of the presence of negatively charged lipid headgroups.

1,2-Dipalmitoylphosphatidylcholine↗

Tapping-mode atomic force microscopy on intact cells: optimal adjustment of tapping conditions by using the deflection signal.

Difficulties in the proper adjustment of the scanning parameters are often encountered when using tapping-mode atomic force microscopy (TMAFM) for imaging thick and soft material, and particularly living cells, in aqueous buffer. A simple procedure that drastically enhances the successful imaging of the surface of intact cells by TMAFM is described. It is based on the observation, in liquid, of a deflection signal, concomitant with the damping of the amplitude that can be followed by amplitude-distance curves. For intact cells, the evolution of the deflection signal, steeper than the amplitude damping allows a precise adjustment of the feedback value. Besides its use in finding the appropriate tapping conditions, the deflection signal provides images of living cells that essentially reveal the organization of the membrane cytoskeleton. This allows to show that changes in the membrane surface topography are associated with a reorganization of the membrane skeleton. Studies on the relationships between the cell surface topography and membrane skeleton organization in living cells open a new field of applications for the atomic force microscope.

Animals↗

The use of atomic force microscopy for the observation of corneal epithelium surface.

PURPOSE: To evaluate the feasibility of imaging normal corneal epithelium by means of atomic force microscopy (AFM). METHODS: Twelve normal corneas from six albino rabbits were examined using a commercial atomic force microscope. Six corneas were examined in balanced salt solution after fixation in glutaraldehyde 2.5% and six without any fixation. Rectangular silicon nitride cantilevers with a spring constant of 10 to 20 mN/m were used. The measured forces after imaging were less than 100 pN. All reported images were made with 512x512-pixel definition with typical scan rates ranging from 1 to 5 Hz. RESULTS: High-quality images of corneal epithelium surface were obtained from fixed and unfixed specimens in magnifications ranging from x2000 to x2,000,000. Imaging of fixed specimens was always easier. In unfixed specimens fuzzy images were very common, probably because of the presence of the cell glycocalyx. AFM revealed the typical polygonal corneal epithelial cells. The cell surface was covered by microprojections; at cell borders the microprojections were arranged in two characteristic parallel rows. Craterlike formations were revealed in several specimens. The microprojections' morphology and their surface details were revealed using magnifications up to x2,000,000. Three-dimensional representation of the images facilitated better understanding of the surface topography. Measurements in horizontal and vertical plane were made using the section analysis tool. CONCLUSIONS: In this work the AFM parameters appropriate for corneal epithelium imaging in physiological medium were defined. AFM represents a new powerful tool for corneal epithelium imaging, and its application in this field warrants further investigation.

Animals↗

Lipid-induced organization of a primary amphipathic peptide: a coupled AFM-monolayer study.

To better understand the nature of the mechanism involved in the membrane uptake of a vector peptide, the interactions between dioleoylphosphatidylcholine and a primary amphipathic peptide containing a signal peptide associated with a nuclear localization sequence have been studied by isotherms analysis of mixed monolayers spread at the air-water interface. The peptide and the lipid interact through strong hydrophobic interactions with expansion of the mean molecular area that resulted from a lipid-induced modification of the organization of the peptide at the interface. In addition, a phase separation occurs for peptide molar fraction ranging from about 0.08 to 0.4 Atomic force microscopy observations made on transferred monolayers confirm the existence of phase separation and further reveal that mixed lipid-peptide particles are formed, the size and shape of which depend on the peptide molar fraction. At low peptide contents, round-shaped particles are observed and an increase of the peptide amount, simultaneously to the lipidic phase separation, induces morphological changes from bowls to filamentous particles. Fourier transform infrared spectra (FTIR) obtained on transferred monolayers indicate that the peptide adopts a beta-like structure for high peptide molar fractions. Such an approach involving complementary methods allows us to conclude that the lipid and the peptide have a nonideal miscibility and form mixed particles which phase separate.

Lipids↗

Imaging of the surface of living cells by low-force contact-mode atomic force microscopy.

The membrane surface of living CV-1 kidney cells in culture was imaged by contact-mode atomic force microscopy using scanning forces in the piconewton range. A simple procedure was developed for imaging of the cell surface with forces as low as 20-50 pN, i.e., two orders of magnitude below those commonly used for cell imaging. Under these conditions, the indentation of the cells by the tip could be reduced to less than l0 nm, even at the cell center, which gave access to the topographic image of the cell surface. This surface appeared heterogeneous with very few villosities and revealed, only in distinct areas, the submembrane cytoskeleton. At intermediate magnifications, corresponding to 20-5 microm scan sizes, the surface topography likely reflected the organization of submembrane and intracellular structures on which the plasma membrane lay. By decreasing the scan size, a lateral resolution better than 20 nm was routinely obtained for the cell surface, and a lateral resolution better than 10 nm was obtained occasionally. The cell surface appeared granular, with packed particles, likely corresponding to proteins or protein-lipid complexes, between approximately 5 and 30 nm xy size.

Animals↗

Atomic force microscopy of renal cells: limits and prospects.

In this brief review, we present three-dimensional images of living Madin-Darby canine kidney (MDCK) cells and CV-1 cells that illustrate the possibilities and limits in the use of atomic force microscopy (AFM) for studying the topography of the cell surfaces and of isolated biological membranes. We show that microvilli can be imaged at the surface of living epithelial cells. However, when these microvilli are abundant and close to each other, the geometry of the AFM tip only allows an access to the upper part of the structures and precludes nanometer range imaging of the cell surface. Such a nanometer range imaging was obtained with other cell types like CV-1 cells and with isolated biological membranes. It reveals that protruding particles 5 to 60 nm xy size, likely corresponding to membranes proteins, occupy most of the membrane surface. These images indicate that the AFM already gives an access to the cell surface structure at the mesoscopic scale, which constitutes a major step for the understanding of the structure-function relationships in membranes. Perspectives for a further step, the imaging at molecular resolution of membranes, are discussed.

Animals↗

Simultaneous imaging of the surface and the submembraneous cytoskeleton in living cells by tapping mode atomic force microscopy.

Contact and tapping mode atomic force microscopy have been used to visualize the surface of cultured CV-1 kidney cells in aqueous medium. The height images obtained from living cells were comparable when using contact and tapping modes. In contrast, the corresponding, and simultaneously acquired, deflection images differed markedly. Whereas, as expected, deflection images enhanced the surface features in the contact mode, they revealed the presence of a filamentous network when using the tapping mode. This network became disorganized upon addition of cytochalasin, which strongly suggests that it corresponded to the submembraneous cytoskeleton. Examination of fixed cells further supported this assumption. These data show that, in addition to the structural information on the cell surface, the use of the tapping mode in liquid can also provide a good visualization of the membrane cytoskeleton. Tapping mode atomic force microscopy appears to be a promising technique for studying interactions between cell surface and subsurface structures, a critical step in many biological processes.

Animals↗

Imaging of the cytoplasmic leaflet of the plasma membrane by atomic force microscopy.

The cytoplasmic face of ventral cell membranes of Madin-Darby canine kidney (MDCK) cells grown on glass coverslips was imaged by atomic force microscopy (AFM) in air and under aqueous medium, in "contact" mode. Micrometer range scans on air-dried samples revealed a heterogeneous structure with some filaments, likely corresponding to actin filaments that abut the inner leaflet of the membrane, and a few semi-organized lattice structures that might correspond to clathrin lattices. Experiments in phosphate-buffered saline confirmed the heterogeneity of the inner membrane surface with the presence of large (> 100 nm) globular structures emerging from the surface. Using sub-micrometer scan ranges, protruding particles, that occupy most of the membrane surface, were imaged in liquid medium and in air. These particles, 8 to 40 nm x-y size, were still present following ethanol dehydration which extracts a large fraction of membrane lipids, indicating their proteic nature. Due, at least partly, to the presence of some peripheral proteins, high magnification images of the inner membrane surface were heterogeneous with regard to particle distribution. These data compare with those previously reported for the external membrane leaflet at the surface of living MDCK cells. They show that details of the cytosolic membrane surface can be resolved by AFM. Finally, the images support the view of a plasma membrane organization where proteins come into close proximity.

Air↗

Imaging of the membrane surface of MDCK cells by atomic force microscopy.

The membrane surface of polarized renal epithelial cells (MDCK cells) grown as a monolayer was imaged with the atomic force microscope. The surface topography of dried cells determined by this approach was consistent with electron microscopy images previously reported. Fixed and living cells in aqueous medium gave more fuzzy images, likely because of the presence of the cell glycocalix. Treatment of living cells with neuraminidase, an enzyme that partly degrades the glycocalix, allowed sub-micrometer imaging. Protruding particles, 10 to 60 nm xy size, occupy most of the membrane surface. Protease treatment markedly reduced the size of these particles, indicating that they corresponded to proteins. Tip structure effects were probably involved in the exaggerated size of imaged membrane proteins. Although further improvements in the imaging conditions, including tip sharpness, are required, atomic force microscope already offers the unique possibility to image proteins at the membrane surface of living cells.

Animals↗

Scanning tunnelling microscopy of 16S ribosomal RNA in water.

The scanning tunnelling microscope has been used to image 16S ribosomal RNA molecules in water electrophoretically deposited on graphite surface. Two kinds of images have been obtained: images showing aggregates of 16S ribosomal RNA molecules similar to those obtained from DNA solutions and others showing individual 16S ribosomal RNA molecules. An interesting characteristic of these images, recorded in constant current mode, is that the 16S ribosomal RNA molecules appear to be located below the graphite surface. The morphology and several structural parameters of the molecules were consistent with the data obtained from electron microscopy.

Centrifugation, Zonal↗