B-flow and B-flow with 3D and SRI postprocessing before intervention and monitoring after stenting of the internal carotid artery.

OBJECTIVE: To investigate the extent to which B-flow and B-flow with 3D postprocessing and speckle reduction imaging (SRI) have advantages in appraising the morphology of a high-grade stenosis of the internal carotid artery (ICA) for preinterventional planning and for postinterventional ultrasonographic follow-up. MATERIALS/METHODS: A comparative appraisal of flow with CCDS, power Doppler, B-flow and 3D B-Flow with SRI were carried out prospectively in 50 patients with >70% stenosis according to NASCET criteria in contrast medium-enhanced MRA before and after the intervention. After stenting of the internal carotid artery (ICA), i.a. digital substraction angiography (DSA) served as an additional reference method. RESULTS: In >70% ICA stenosis, simultaneous imaging of the pre-stenotic, intra-stenotic and post-stenotic flow was attained with B-flow in 45/90 cases (90%), with power Doppler in 39/50 cases (78%) and with CCDS in only 31/50 cases (62%). After intervention, a complete detection of flow without overwriting or blooming artifacts was achieved in all 50 patients only by B-flow. The intrastenotic flow (p<0.05) could be better demarcated against the lumen and the vessel wall before the intervention, whereas the flow within the stent could be very much better appraised after the intervention (p<0.01) using 3D postprocessing of B-flow with additional SRI. Re-stenoses with hypoechoic vascular wall changes (3/50 patients) were detected at an early stage using B-flow. CONCLUSIONS: B-flow technique with SRI and 3D postprocessing can facilitate the intrastenotic detection of flow in >70% ICA stenosis with fewer flow artifacts. After stenting, the perfused vascular lumen shows less flow artifacts compared with CCDS and power Doppler. In order to elucidate hemodynamic changes, additional Doppler examinations are still necessary.

Aged↗

Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography.

The purpose of this study is to investigate the diagnostic potential of color-coded Doppler sonography (CCDS), power-Doppler (PD) and B-flow ultrasound in assessing the degree of extracranial internal carotid artery (ICA) stenosis in comparison to CT-angiography (MD-CTA). Thirty-two consecutive patients referred for CTA with 41 ICA-stenoses were included in this prospective study. MD-CTA was performed using a 64 row scanner with a CTDIvol of 13.1 mGy/cm. In CTA, CCDS, PD and B-flow, the degree of stenosis was evaluated by the minimal intrastenotic diameter in comparison to the poststenotic diameter. Two radiologists performed a quantitative evaluation of the stenoses in consensus blinded to the results of ultrasound. These were correlated to CTA, CCDS, PD and B-flow, intraoperative findings and clinical follow-up. Grading of the stenoses in B-flow ultrasound outperformed the other techniques in terms of accuracy with a correlation coefficient to CTA of 0.88, while PD and CCDS measurements yield coefficients of 0.74 and 0.70. Bland-Altman analysis additionally shows a very little bias of the three US methods between 0.5 and 3.2 %. There is excellent correlation (coefficient 0.88, CI 0.77-0.93) with 64-MD-CTA and B-flow ultrasound in terms of accuracy for intrastenotic and poststenotic diameter. Duplex sonography is useful for screening purposes.

Aged↗

Cost analysis in interventional radiology--A tool to optimize management costs.

OBJECTIVE: The objective of the study was to analyze the methods to reduce cost in interventional radiology departments by reorganizing procurement. MATERIALS AND METHODS: All products used in the Department of Interventional Radiology were inventoried. An ABC-analysis was completed and A-products (high-value and high turnover products) underwent a XYZ-analysis which predicted demand on the basis of ordering frequency. Then criteria for a procurement strategy for the different material categories were fixed. The net working capital (NWC) was calculated using an interest rate of 8%/year. RESULTS: Total annual material turnover was 353,000 euro. The value of all A-products determined by the inventory was 260,000 euro. Changes in the A-product procurement strategy tapped a cost reduction potential of 14,500/year euro. The resulting total saving was 17,200 euro. Improved stores management added another 37,500 euro. The total cost cut of 52,000 euro is equivalent to 14.7% of annual expenses. CONCLUSION: A flexible procurement strategy helps to reduce the storage and capital tie-up costs of A-products in interventional radiology without affecting the quality of service provided to patients.

Cost Control↗

High-grade stenoses of the internal carotid artery: comparison of high-resolution contrast enhanced 3D MRA, duplex sonography and power Doppler imaging.

PURPOSE: The objective of this study was to determine the agreement and diagnostic accuracy of high-resolution contrast enhanced magnetic resonance angiography (MRA) with integrated parallel acquisition techniques (iPAT), color coded duplex ultrasound (CCDS) and power Doppler ultrasound (PD) in the assessment of high-grade stenoses of the internal carotid artery (ICA). METHODS: Forty-four patients with 52 known or suspected stenoses of the internal carotid artery (ICA) were included in this prospective study. High-resolution MRA scans with a spatial resolution of 0.9 mm x 0.7 mm x 0.9 mm were acquired with an iPAT acceleration factor of 2 on a 1.5T MR system (Sonata Maestro Class, Siemens Medical Solutions, Erlangen, Germany) with a head, neck and body coil. For the 3D-CE MRA a fast spoiled gradient echo sequence (FLASH) was used. To compensate for the inherent signal loss with parallel imaging, a 1M contrast agent (gadobutrol, Gadovist, Schering, Berlin, Germany) was used. Stenoses were quantified by two readers in consensus in cross-sectional area measurements and graded according to the NASCET criteria. Using color coded duplex ultrasound (CCDS) and power Doppler (PD; Logiq 9, GE), the stenoses were also graded by two readers in consensus according to the NASCET criteria from intra- and post-stenotic diameter measurements. The results of MRA, CCDS and PD were compared to intraoperative findings or to follow-up examinations. RESULTS: High-resolution MRA allowed an excellent grading of vascular stenoses. In 70-90% degrees of stenosis there was an underestimation of the degree of stenosis in MRA as well as in CCDS. However, there was an overestimation of 90% stenoses in both MRA and CCDS. Pseudoocclusions with a lumen of less than one millimeter were occasionally rated as a complete occlusion in MRA. CONCLUSION: A combination of MRA and duplex sonography seems reasonable for the accurate grading of stenoses and determination of distal stenoses downstream. However, the accuracy of duplex ultrasound depends on the examiner's experience.

Aged↗

Value of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) in detection and characterisation of breast tumours.

The purpose of this study was to investigate the extent to which tissue harmonic imaging (THI), speckle reduction imaging (SRI), spatial compounding (SC) and contrast can improve detection and differentiation of breast tumours. We examined 38 patients (14 benign, 24 malignant tumours) with different combinations of THI, SRI and SC. The effect on delineation, margin, tissue differentiation and posttumoral phenomena was evaluated with a three-point score. Additionally, 1oo not palpable tumours (diameters: 4-15 mm) were examined by contrast harmonic imaging (CHI) with power Doppler. After bolus injection (0.5 ml Optison), vascularisation and enhancement were observed for 20 min. The best combination for detection of margin, infiltration, echo pattern and posterior lesion boundary was the combination of SRI level 2 with SC low. THI was helpful for lesions OF more than 1 cm depth. In native Power Doppler, vessels were found in 54 of 100 lesions. Within 5 min after contrast medium (CM) injection, marginal and penetrating vessels increased in benign and malignant tumours and central vessels mostly in carcinomas (p<0.05). A diffuse CM accumulation was observed up to 20 min after injection in malignant tumours only (p<0.05). THI, SRI and SC improved delineation and tissue differentiation. Second-generation contrast agent allowed detection of tumour vascularisation with prolonged enhancement.

Adult↗

Diagnostics and characterisation of preocclusive stenoses and occlusions of the internal carotid artery with B-flow.

The purpose was to evaluate whether B-flow can improve the ultrasonographic diagnosis of preocclusive stenosis and occlusion of the internal carotid artery (ICA) compared with colour-coded Doppler and power Doppler. Ninety patients with occlusions or preocclusive stenoses of the ICA suspected by Doppler sonography were examined with B-flow in comparison with colour-coded Doppler sonography (CCDS), power Doppler (PD) and intra-arterial digital subtraction angiography (DSA). Intrastenotic flow detection and lengths of stenoses were the main criteria. Ulcerated plaques found by surgery in 42/90 patients were compared by ultrasonography (US). Diagnosis of ICA occlusion with CCDS, PD and B-flow was correct in all 42 cases. A preocclusive ICA stenosis in DSA was detected correctly in all 48/48 cases (100%) for B-flow, in 44/48 (92%) for PD and in 39/48 (81%) for CCDS. Surgical findings showed in 17/42 cases ulcerated plaques; 15/17 (89%) of these cases were detected with B-flow, 12/17 (71%) with PD, 10/17 (59%) with CCDS, and 8/17 (47%) with DSA. With B-flow the extent of stenosis was appraised more precisely than with PD and CCDS (P<0.0001). In conclusion, B-flow is a reliable method for preocclusive stenosis of the ICA with less intrastenotic flow artefacts. B-flow facilitates the characterization of plaque morphologies.

Aged↗

Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison).

PURPOSE: To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. MATERIALS/METHODS: 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. RESULTS: Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85%) of HCC cases. All 19 hemangiomas were correctly classified by phase inversion imaging. CONCLUSIONS: Contrast medium-enhanced ultrasound investigation of liver tumors with Optison allowed reliable detection of tumor foci and, in most cases, appraisal of tumor vascularization. The time available for evaluation of tumor margin vascularization was substantially longer in B-flow.

Adult↗

[Patient safety in diagnostic ultrasound I--fundamentals].

Diagnostic ultrasound is not totally free of side effects. Therefore, the principle of good clinical practise and ALARA must be considered. In particular inpulsed wave Doppler examinations critical values can be exceeded. Potentially, damage can be the result. Also ultrasound contrast agents are not absolutely free of side effects. The most important risk, of course, are ultrasound examinations performed by inadequat skilled physicians.

Contrast Media↗

[Patient safety in diagnostic ultrasound II--ultrasound guided interventions].

New digital ultrasound techniques simplify the documentation of ultrasound images and allow better comparison with respect to different image modalities. New vascular imaging modes including contrast enhanced power Doppler and 3D power Doppler allow for the detection of very small vessels and leakages. B-flow, a recently introduced digital substraction technique is advancing the detection of residual blood flow in high-grade stenosis without vibration artifacts. Modern contrast agents allow to perform ultrasound guided intervetion such as biopsies and ablation therapies with improved accuracy. This way, the risk for complications can be significantly reduced.

Aortic Aneurysm, Abdominal↗

Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography.

The purpose was to evaluate the diagnostic results of different ultrasound techniques: color-coded Doppler (CCD), power Doppler (PD) and B-flow in the diagnosis of vascular dissection. Findings from 68 patients with arterial dissection proven either by vascular ultrasound (US) or by magnetic resonance angiography (MRA), computed tomographic angiography (CTA) or intra-arterial digital subtraction angiography (DSA) were reviewed in retrospect. The study compared results from three different modes of ultrasound, i.e., CCD, PD and B-flow, in dissections of the carotid artery (n=11), of the vertebral artery (n=9), of the abdominal aorta (n=13), of the iliac artery (n=12) and of the femoral artery (n=23). MRA, CTA and DSA were considered as reference standard. The sensitivity of CCD for detecting all dissections was 78%, 84% for the PD and 98% for B-flow. For carotid artery dissection, the sensitivity of CCD, PD and B-flow was 82, 91 and 98%, for the vertebral artery 67, 78 and 98%, for the abdominal aorta 85, 85 and 98%, for the iliac artery 67, 75 and 98%, for the femoral artery 83, 87 and 98%, respectively. Intima flaps, fissures of membranes and residual flow within the true and false lumen were better detected by B-flow than by CCD and PD. The lack of angle dependence of the US probe in B-flow made the examination procedure easier. In the cine mode of B-flow, the pulse synchronic movement of the membrane was more apparent than in any other imaging method. With B-flow, accuracy for the diagnosis of arterial dissection is improved compared to CCD and PD. Flow within the true and false lumen, low-echo thrombi, intramural hematoma and even movements of the dissection membrane are clearly distinguished.

Adult↗

[Materials management system in interventional radiology -- initial experience with a computer-supported program].

PURPOSE: To perform a cost analysis for assessing options of reorganizing material supplies and reducing costs of the radiology division through the introduction of a materials management system. MATERIALS AND METHODS: A materials management system (Piranha, Boston Scientific) was installed on an existing computer system. All consumables were inventoried and entered into the system. An ABC analysis determined further action. On the basis of order frequencies and availability requirements for emergencies, safety levels were agreed with physicians and other medical staff. Inventory costs were computed using these data. The interest rate for the capital tied up in the inventory was 8 % per year. RESULTS: The inventory showed that the capital tied up in stocks was euro 260,000 in 2001 and euro 190,000 in 2002. A change in supply strategy reduced inventory cost in 2001 and 2002. Annual interest expense was lowered by euro 18,420. Another saving of euro 2,700 was achieved by a reduction in storage cost. Annual inventory turnover totaled euro 298,000. The total cost cut through improved inventory management was euro 21,120 per year, which is equivalent to 7 % of the annual expenses. Adding the decline in the cost of shelf time overruns equal to 5 % of the annual expenses, the saving was approximately 12 % of total interventional radiology cost in 2001 and some 11 % in 2002. CONCLUSION: Flexible supply strategies and the introduction of a materials management program can help to reduce inventory costs in interventional radiology divisions without any impact on service levels.

Computer Systems↗

[Tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) for sonographically guided vacuum-assisted biopsy of mammographically occult breast tumors].

PURPOSE: To assess the guidance of tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) for vacuum assisted biopsies of suspicious breast lesions compared to fundamental B-mode ultrasound-guided biopsies. MATERIAL AND METHODS: In 550 patients, ultrasound examinations of the breast were performed prospectively using fundamental B-scan, THI, and CHI. Focal lesions were documented in comparable projections for all three ultrasound modes. As contrast agent, a dose of 0.5 milliliters of Perflutren Protein-Type A microspheres ( Optison) was injected. An ultrasound-guided biopsy was performed in 38 focal lesions. Three radiologists experienced in breast imaging retrospectively assessed the lesions on the ultrasound images. RESULTS: Thirty-eight suspicious focal lesions [size 4 - 15 mm; median 8 mm] were detected by ultrasound. Of these, 29 were detected by fundamental B-scan images, 34 by THI, and 38 by CHI. Ultrasound-guided biopsy was performed on all of these lesions. No complications related to the biopsy were observed. In 25/38 cases, invasive carcinomas were found; in 6/38 ductal carcinomas in situ; in 3 cases metastases of already known invasive ductal carcinomas; and in 4 cases fibroadenomas. The size of the lesion was best identified using THI, smaller lesions (< 10 mm) using CHI. CONCLUSION: THI and CHI can help to detect focal lesions in dense breasts. Both modes can make it easier to perform ultrasound-guided biopsies of focal breast lesions.

Biopsy, Needle↗

[Investigation of the entrance dose of standardized chest radiographs].

In 50 chest radiographs obtained in PA projection with the patient erect and the radiographic techniques kept constant, entrance dose, entrance surface dose and dose area product were measured and compared with the measurements obtained with Plexiglas and Alderson phantoms. Following the recommendations of the International Commission on Radiological Protection, the "absorbed dose in air" at the point of intersection of the X-ray beam with the surface of the patient was used as reference. For patients with the same diameter, the measured dose deviated up to +/- 50 % from the "Reference Man" according to the ICRP 23 as well as from the "Representative Patient" according to the ICRP 73. The exposure data produced by the equipment corresponded to the measured values with minor deviations, but the dose values expressed as entrance surface dose showed major deviation in comparison with the entrance dose due to differences in the back-scatter factor. The values of entrance dose calculated from the dose area product measurements showed additional uncertainties due to different field sizes. Moreover, a sex-specific dose area product value was identified. These results reveal that the values of the "ICRP Reference Man" differ in many situations from the values produced by the examined patient due to differences in radiation transmission. This has consequences for determining diagnostic reference values and investigating recorded radiation exposure. This will be explained and substantiated.

Humans↗

Blood fluidity, fibrinogen, and cardiovascular risk factors of occlusive arterial disease: results of the Aachen study.

In the Aachen study the prevalence of arterial disease was established in 346 out of a cohort of 2821 subjects between 45 and 65 years of age. Rheological variables and risk factor profile for patients with peripheral occlusive arterial disease (POAD), coronary heart disease (CHD) and cerebrovascular insufficiency (CI) in comparison to a control group are given. Significantly elevated are hematocrit in males, plasma viscosity, erythrocyte aggregation and fibrinogen. It is evident that plasma viscosity is the rheological parameter most often elevated in patients with arterial disease (70.8%). In patients with CI (80.6%) plasma viscosity is elevated about four times more often than in healthy subjects. While 85.8% of healthy volunteers show no or only one elevated rheological parameter only 44.5% of the patients have this constellation. Risk factors are bundled in patients compared to healthy volunteers. 84.2% of the healthy volunteers have no or only one risk factor whereas patients with OAD show this constellation in only 30.9% (32.4% in POAD, 16.1% in CI and 32.4% in CHD).

Blood Viscosity↗

[Improved evaluation of stenoses of hemodialysis fistulas by B-flow ultrasound].

PURPOSE: To evaluate the new technique of B-flow ultrasound in assessing stenoses of hemodialysis fistulas. MATERIALS AND METHODS: 50 patients (mean age 58 years) with Brescia-Cimino-Shunts (27 shunts of the radial and 23 of the cubital artery) were prospectively assessed with intraarterial DSA and vascular ultrasound by independent examiners. Eligibility for the study was a shunt-volume of less than 400 ml/min and an angiographically suspected hemodynamically significant stenosis of the anastomosis or of shunt veins. Sonography was performed with a multifrequency ultrasound probe (5 to 10 MHz, Logic 700, GE) using B-mode, color coded Doppler sonography (CCDS) and B-flow technique. RESULTS: Anastomotic stenosis and stenosis of the shunt veins were equally distributed, found in 25 patients each. The measurements of the residual lumen of the 25 anastomotic stenoses were 1.47 to 3.43 mm (average: 2.3 mm) for intraarterial DSA, 1.57 to 3.73 mm (average: 2.6 mm) for B-mode ultrasound, 1.97 to 4.17 mm (average: 2.9 mm) for CCDS, 1.43 to 3.47 mm (average: 2.3 mm) for B-flow technique in the brightness mode and 1.6 to 3.47 mm (average: 2.4 mm) for B-flow technique in the B-mode. The brightness mode of the B-flow correlated best with intraarterial DSA (r=0.994), with a significantly lower correlation between CCDS and intraarterial DSA. B-flow displays less vascular distortion within the stenosis and fewer flow artifacts. Even in angulated stenoses, the detected intra- and poststenotic flow was markedly less angle-dependent in comparison with CCDS. B-flow clearly facilitates the visualization of hypoechoic plaques and intima proliferation. Furthermore, eccentric cicatricial stenoses, intima flaps or hypoechoic thrombi, which were not seen with DSA or B-mode, showed improved visualization in comparison with CCDS. CONCLUSION: Ultrasound B-flow makes it easier to assess the morphology and the local degree of stenotic hemodialysis fistulas. Flow detection is achieved with fewer artifacts and reduced angle dependence. This opens the way for better planning of interventional therapy.

Aged↗

[B-flow and color-coded B-flow in sonographic diagnosis of filiform stenosis of the internal carotid artery].

PURPOSE: To evaluate B-flow ultrasound in filiform (> 90 %) stenosis or occlusion of the internal carotid artery (ICA) and to compare it with other imaging modalities. METHODS AND MATERIALS: Fifty patients with suspected occlusion or filiform stenosis of the internal carotid artery (ICA) on Doppler ultrasound were examined using B-flow ultrasound in either color-coded or brightness mode. The pre-, intra- and poststenotic flow phenomena were compared with color-coded duplex (CCD) and power Doppler (PD) ultrasound. A contrast agent (Optison) was injected in 15 cases. The results were compared with those of selective intraarterial DSA and in 15 cases also with those of MR-angiography (MRA). Twenty-two patients came to surgical intervention. RESULTS: Diagnosis of ICA occlusion was correct in all 22 cases using CCD, PD and B-flow ultrasound. A filiform ICA-stenosis was correctly seen in all 28 cases when using brightness-modulated or color-coded B-flow or contrast-enhanced power Doppler, but only in 15 cases when using CCD. All 9 ulcerated plaques with appositional thrombi were detected with B-flow, but only 4 cases with CCD. Pre-, intra- and poststenotic flow phenomena in the longitudinal scan were demonstrated simultaneously using color-coded B-flow in 27 out of 28 cases, but only in 17 cases using CCD and in 22 cases using PD. In the 15 cases given contrast agent, B-flow showed no superimposed vessel walls (reverberation artefacts) in the intra- and poststenotic area. In the longitudinal scan, true extend and degree of the distal stenosis of ICA carotid artery stenosis were more precisely measured with B-flow than with PD and CCD. CONCLUSIONS: The ultrasound diagnosis of filiform stenosis of the ICA is more reliable with B-flow ultrasound than with other ultrasound modalities. B-flow ultrasound has flow phenomena that are less angle-dependent and that are better demarcated against the vessel walls. It is free of superimposed vessel walls and offers better simultaneous intra- and poststenotic flow detection. The improved delineation of the plaque morphology by B-flow ultrasound enables a better evaluation of ulcerations and possible thrombi.

Aged↗

[Contrast-enhanced ultrasound with Optison in percutaneous thermoablation of liver tumors].

PURPOSE: To detect vascularization of liver tumors by ultrasound enhanced with Optison and to determine whether increasing necrosis during a percutaneous thermal ablation can be visualized by this method. MATERIALS AND METHODS: Twenty-two patients with non-resectable malignant liver tumors (9 patients with HCC, 13 patients with metastases) and a total number of 34 lesions underwent percutaneous radiofrequency thermoablation using a needle applicator perfused with a 0.9 % NaCl solution (Electrotome HiTT 106, Berchtold). The tumor size ranged from 2 to 8 cm with an average size of 3.6 cm. While intermittent energy was supplied during thermoablation, multi-slice CT (Volume-Zoom, Siemens) and ultrasound were obtained. Ultrasound was performed with a multi-frequency transducer (3 - 7 MHz, LOGIQ 700, GE) and 0.5 to 1 ml of Optison as contrast agent. If necessary, the injection of the contrast agent was repeated after about 30 min. The mechanical index (MI) was set low (0.2 - 0.3) to prevent bubble destruction. Ultrasound power Doppler (PD), contrast harmonic imaging (CHI) and coded harmonic angiography (CHA) as subtraction mode of harmonic imaging were applied intermittently. RESULTS: Only 21 of the 34 lesions showed increased intratumoral perfusion when the conventional B-Mode with PD was used. Similar to spiral CT, the tumor vascularization in the early arterial phase was only reliably visible with CHA after application of contrast agent. CHI with PD was best to detect increasing hypoperfusion of the tumors. When the energy supply was continued, hyperechoic border zones became visible around the central hypoechoic defects. The contrast between remaining tumor and surrounding liver tissue improved in CHI for up to 30 min after the bolus injection of contrast medium, considerably facilitating the evaluation of perfusion. Metal artifacts and the limited amount of contrast agent that can be safely administered interfered with monitoring the thermal ablation with spiral-CT. After an administered energy of maximal 100.000 watts, no more tumor vascularization was seen in 28 of 34 cases. Follow-up spiral-CT showed a complete necrosis in these cases. CONCLUSION: Evaluating perfusion with contrast-enhanced ultrasound may be helpful in monitoring the evolving necrosis during thermoablation of liver tumors. The more reliable assessment of the tumor necrosis enables a more targeted therapy.

Aged↗