Comparison of BMD precision for Prodigy and Delphi spine and femur scans.

INTRODUCTION: Precision error in bone mineral density (BMD) measurement can be affected by patient positioning, variations in scan analysis, automation of software, and both short- and long-term fluctuations of the densitometry equipment. Minimization and characterization of these errors is essential for reliable assessment of BMD change over time. METHODS: We compared the short-term precision error of two dual-energy X-ray absorptiometry (DXA) devices: the Lunar Prodigy (GE Healthcare) and the Delphi (Hologic). Both are fan-beam DXA devices predominantly used to measure BMD of the spine and proximal femur. In this study, 87 women (mean age 61.6+/-8.9 years) were measured in duplicate, with repositioning, on both systems, at one of three clinical centers. The technologists were International Society for Clinical Densitometry (ISCD) certified and followed manufacturer-recommended procedures. All scans were acquired using 30-s scan modes. Precision error was calculated as the root-mean-square standard deviation (RMS-SD) and coefficient of variation (RMS-%CV) for the repeated measurements. Right and left femora were evaluated individually and as a combined dual femur precision. Precision error of Prodigy and Delphi measurements at each measurement region was compared using an F test to determine significance of any observed differences. RESULTS: While precision errors for both systems were low, Prodigy precision errors were significantly lower than Delphi at L1-L4 spine (1.0% vs 1.2%), total femur (0.9% vs 1.3%), femoral neck (1.5% vs 1.9%), and dual total femur (0.6% vs 0.9%). Dual femur modes decreased precision errors by approximately 25% compared with single femur results. CONCLUSIONS: This study suggests that short-term BMD precision errors are skeletal-site and manufacturer specific. In clinical practice, precision should be considered when determining: (a) the minimum time interval between baseline and follow-up scans and (b) whether a statistically significant change in the patient's BMD has occurred.

Absorptiometry, Photon↗

Assessment of osteoporosis-website quality.

INTRODUCTION: The Internet provides great opportunities for patient healthcare education, but poses risks that inaccurate, outdated, or harmful information will be disseminated. Osteoporosis is a topic of great interest to patients, many of whom use the Internet to obtain medical information. The aim of this study was to develop and evaluate measurement tools to determine the quality of osteoporosis websites for patients. METHODS: Quality indicators in the categories of content, credibility, navigability, currency, and readability were incorporated into separate evaluation tools for healthcare professionals and for patients. Websites were selected from an Internet search. Interobserver reliability and validity were assessed, and a sample of osteoporosis websites was evaluated by an osteoporosis nurse educator and compared to patient evaluations. RESULTS: For the quality indicators, there was 79% agreement between the osteoporosis nurse educators, 88% agreement between the physician osteoporosis experts, and 71% agreement comparing the osteoporosis nurse educators to the physician osteoporosis experts. Quality scores for evaluated websites ranged from 18-96 (maximum possible=100), with a mean of 66. Websites with Uniform Resource Locator (URL) suffix .com scored significantly lower compared to those with .gov (P<0.05), .edu (P<0.01), and .org (P<0.01). Healthcare professionals and patients were in agreement on the quality of the highest-rated websites, with less agreement for lower-rated websites. CONCLUSIONS: In summary, a tool for measuring the quality of medical websites was developed and evaluated. Significant variability in osteoporosis-website quality was observed. Higher-quality scores were associated with a higher level of search engine match and specific URL suffixes. A validated tool for evaluating medical websites may have value in assisting patients to select high-quality osteoporosis educational information on the Internet, and may encourage website developers to improve the quality of information that is provided.

Evaluation Studies as Topic↗

Clinical applications of bone density testing for osteoporosis.

Bone mineral density (BMD) testing is a clinical tool to diagnose osteoporosis or low bone density, predict fracture risk, and monitor changes in bone density over time. Non-invasive measurement of BMD is done with a variety of technologies for many different skeletal sites. Dual-energy X-ray absorptiometry (DXA) is the gold-standard for diagnosing osteoporosis and monitoring changes in BMD over time. Optimal use of DXA requires staff training and standard operating procedures that include quality controls for instrument maintenance, patient education, indications and contraindications for testing, precision assessment, scan acquisition, analysis, interpretation, and reporting. Other technologies, as well as DXA, are used to estimate the risk of fracture. BMD is commonly expressed as a T-score, the standard deviation variance of the patient's BMD compared to a young-normal reference population. In untreated postmenopausal women, there is a strong correlation between T-score and fracture risk, with fracture risk increasing about two-fold for every standard deviation decrease in bone density. BMD in postmenopausal women is classified as normal, osteopenia, or osteoporosis according to criteria established by the World Health Organization. BMD testing, combined with assessment of clinical risk factors for fracture, allows healthcare providers to identify patients who may benefit from pharmacologic therapy to reduce the risk of future fractures. Clinical applications of BMD testing are presented in this review.

Absorptiometry, Photon↗

Special report on the official positions of the International Society for Clinical Densitometry.

The International Society for Clinical Densitometry (ISCD) periodically holds Position Development Conferences (PDCs) for the purpose of establishing standards and guidelines for indications, acquisition, and interpretation of bone density tests. Topics are selected for consideration by the ISCD Scientific Advisory Committee, reviewed by scientific working groups, and presented to an international panel of experts. Topic categories addressed to date include indications for bone density testing, selection of reference databases for T-scores and Z-scores, clinical applications for central and peripheral bone densitometry, serial bone density testing, instrument precision assessment, phantom scanning and calibration testing, requirements for a bone density report, nomenclature, and diagnosis of osteoporosis in postmenopausal women, premenopausal women, men, and children. Following an open session for public comment and discussion, the panel convenes for consideration of each topic and makes recommendations for positions to the ISCD Board of Directors. Recommendations that are accepted become the Official Positions of the ISCD. This Special Report summarizes the methodology of the ISCD PDCs and presents selected Official Positions of general interest.

Absorptiometry, Photon↗