PubMed Health⌕ Search

Biomedical subjects

E M Pedersen

Publications and source records attributed to E M Pedersen.

At least 37 records · Page 2Linked to original sources

Biplane long-axis magnetic resonance imaging. Survey projections for rapid estimation of left ventricular mass and global function.

OBJECTIVE: To evaluate the accuracy and precision of biplane long-axis magnetic resonance imaging (MRI) and two-dimensional (2D)-echocardiography, for the assessment of left ventricular (LV) mass and volumes, with multislice short-axis MRI as reference standard. DESIGN: Forty-five cardiac patients and four volunteers with varying LV dilatation and hypertrophy were examined by biplane long-axis gradient-echo MRI, 2D-echocardiography, and multiple short-axis gradient-echo MRI. RESULTS: Compared with multislice MRI, the accuracy, i.e. the coefficient of variation (c.v.) of inter-method differences of measured variables, was median 15.7% for biplane MRI and 18.5% for 2D-echocardiography. The precision, expressed as the c.v. of repeated measurements, was median 8.5% for multislice MRI, 9.5% for biplane MRI and 12.4% for 2D-echocardiography. For the determination of LV mass index, MRI was significantly more precise (c.v.: 6.0-8.4%) than 2D-echocardiography (c.v.: 13.7-14.3%, p < 0.05). CONCLUSION: Biplane long-axis MRI is a fast and simplified method, offering the advantage of displaying anatomy and function in recognizable projections. For the estimation of LV mass and volumes, biplane MRI had an acceptable accuracy, and a precision that did not differ significantly from that of multislice MRI.

Aged↗

Heart motion-adapted MR velocity mapping of blood velocity distribution downstream of aortic valve prostheses: initial experience.

PURPOSE: To investigate blood flow velocities and shear rates at two distances downstream of an artificial aortic valve in patients. MATERIALS AND METHODS: Blood velocity was quantified downstream of the valve prosthesis (for replacement after aortic valve stenosis or combined stenosis and regurgitation) in 10 patients by using a magnetic resonance (MR) cine velocity mapping method in which the imaging section position is adapted according to the excursion of the valvular plane of the heart. Two acquisitions were performed to display the blood velocity distributions one-fourth valve diameter and one valve diameter downstream of the valve and to quantify blood volumes and shear rates. RESULTS: The velocity profiles measured during flow acceleration one-fourth valve diameter downstream were characterized by a distinct pattern of two lateral jets and one central jet of antegrade flow. High shear rates were found along the leaflet tips. The profiles obtained one valve diameter downstream were skewed, with varying velocity patterns among patients. Peak shear rates were found close to the vessel wall. With correction for through-plane motion of the valve, the mean apparent regurgitant fraction (+/- SD) was 14% +/- 6; the mean regurgitant fraction without correction was 9% +/- 5. CONCLUSION: The described noninvasive procedure for velocity mapping enables measurements close to the valve and thus evaluation of blood flow patterns with respect to valve design in humans.

Adult↗

Serial magnetic resonance imaging of global and regional left ventricular remodeling during 1 year after acute myocardial infarction.

Biplane long-axis cine MRI was performed in 51 patients 1, 13, 26, and 52 weeks after their first AMI. LV mass index (LVMI) was significantly increased 1 week after AMI (84.3 +/- 16.9 vs. 68.1 +/- 11.4 g/m(2) controls, n = 48, p < 0.001), presumably owing to edema of the infarcted myocardium. Six months after AMI, LVMI decreased to 76.5 +/- 16.4 g/m(2), but had again augmented after 1 year (81.8 +/- 17.3 g/m(2), p < 0.05), suggesting late, compensatory left ventricular hypertrophy. In patients treated with primary percutaneous transluminal coronary angioplasty, LVMI decreased 5% over 1 year, while LVMI increased 10% in patients receiving thrombolysis (p < 0.05). In the entire population, the global increase in LVMI 1 year after AMI seemed to reflect global cavity dilatation with unchanged thickness of the vital myocardium. In conclusion, in patients receiving contemporary treatment, LV remodeling only partially complied with the classical patho-anatomical concept.

Aged↗

Motion correction for the quantification of mitral regurgitation using the control volume method.

Quantifying mitral regurgitation is difficult because of the complexity of the flow, geometry and motion of the mitral valve. In this paper a MRI compatible phantom was built incorporating a left ventricle and mitral valve motion. Valve motion was obtained using a pneumatic piston. The mitral valve was made regurgitant and the regurgitant volume quantified using a modified control volume method. The modification to the method was the addition of mitral motion correction. This was attained by moving the control volume in unison with the mitral valve and by correcting for this motion in the integration of velocity. This correction was found to be simple, in that it represented the volume swept out by the moving control surface. The measured regurgitant volume was compared to a second MR measurement using a single slice technique, made possible by the tubular construction of the phantom's left atrium. Regression analysis between these two methods produced a regression line of y = 0 + 1.02 x; R = 0.97; standard error of the estimate = 3.47 ml.

Blood Flow Velocity↗

Assessment of prosthetic aortic valve performance by magnetic resonance velocity imaging.

OBJECTIVES: Magnetic resonance (MRI) velocity mapping was used to evaluate non-invasively the flow profiles of the ascending aorta in normal volunteers and in patients with an aortic (mechanical) valve prosthesis. BACKGROUND: In patients with artificial aortic valves the flow profile in the ascending aorta is severely altered. These changes have been associated with an increased risk of thrombus formation and mechanical hemolysis. METHODS: Velocity profiles were determined 30 mm distal to the aortic valve in six healthy volunteers and seven patients with aortic valve replacement (replacement within the last 2 years) using ECG triggered phase contrast MRI. Peak flow, mean flow and mean reverse flow were measured in intervals of 25 ms during the entire heart cycle. Systolic reverse flow, end-systolic closing and diastolic leakage volume were calculated for all subjects. RESULTS: Peak flow velocity during mid-systole was significantly higher in patients with valvular prosthesis than in normals (mean + SD, 1.9 +/- 0.4 m/s vs. 1.2 +/- 0.03 m/s, P < 0.001) with a double peak and a zone of reversed flow close to the inner (left lateral) wall of the ascending aorta of the patients. Closing volume was significantly larger in patients than in controls (-3.3 +/- 1.2 ml/beat vs. -0.9 +/- 0.5 ml/beat; P < 0.001). There was reverse flow during systole in valvular patients amounting to 15.7 +/- 6.7% of total cardiac output compared to 2.3 +/- 1.2% in controls (P < 0.001). Diastolic mean flow was negative in patients after valve replacement but not in controls (-11.0 +/- 15.2 ml/beat vs. 6.8 +/- 3.2 ml/beat; P < 0.01). CONCLUSIONS: The following three major quantitative observations have been made in the present study: (1) Mechanical valve prostheses have an increased peak flow velocity with a systolic reverse flow at the inner (left lateral) wall of the ascending aorta. (2) A double peak flow velocity pattern can be observed in patients with bileaflet (mechanical) prosthesis. (3) The blood volume required for leaflet closure and the diastolic leakage blood volume are significantly higher for the examined bileaflet valve than for native heart valves.

Adult↗

Determination of wall shear rate in the human carotid artery by magnetic resonance techniques.

OBJECTIVES: to measure wall shear rates around the circumference of the human carotid bifurcation throughout the heart cycle. DESIGN: prospective, open study. Materials eight healthy volunteers. METHODS: wall shear rates were determined at the carotid bifurcation using magnetic resonance techniques with high resolution and individually adjusted velocity encoding for imaging and haemodynamic mapping. Wall shear stresses were calculated assuming a constant value of 4 centiPoise. RESULTS: data suitable for postprocessing were obtained in all subjects. The main findings were: unidirectional wall shear rate waveforms and high wall shear rate (775 s(-1)+/-167 s(-1)) at the flow divider; low wall shear rate (60 s(-1+/-40 s(-1)) and a high oscillation index with huge interindividual variation (85+/-65) at the lateral wall. CONCLUSION: these are the first in vivo data describing, in detail, the forces of the blood acting on the wall of the carotid bifurcation. The results do not contradict the hypotheses associating low and oscillating wall shear stress with the development of atherosclerosis.)

Adult↗

Magnetic resonance imaging seems safe in patients with intracoronary stents.

We elucidated whether exposure to cardiac magnetic resonance imaging (MRI) of patients with implanted intracoronary stents is associated with increased risk of stent-thrombosis, stent-restenosis, or other cardiovascular complications. Forty-seven patients admitted with acute myocardial infarction (AMI) were studied. Twenty-three were included in a serial cardiac MRI study, using 1.5-T scanners with standard gradient systems. The remaining patients were control subjects who were matched for age and gender with the MRI group. All patient had intracoronary stents implanted in connection with primary angioplastic treatment (PTCA) of AMI (n = 21), secondary PTCA procedures due to recurrent angina (n = 22), or both (n = 4). In the MRI group (n = 23, aged 58 +/- 10 yr), MRI was carried out one to five times in each patient a median of 166 days (range, 1-501) after stent implantation. The control group comprised 24 patients, ages 59 +/- 11 yr. The incidences of stent-thrombosis, stent-restenosis, and other cardiovascular complications did not differ statistically significantly between the two groups. In the MRI group, stent-related thrombosis (n = 1) or restenosis (n = 7) was observed in eight cases a median of 102 days (range, 7-547) after MR examination and a median of 318 days (range, 138-713) after stent implantation, compared with nine cases in the control group (thrombosis, n = 1; restenosis, n = 8) observed a median of 147 days (range, 1-267) after stent implantation. No acute thromboembolic or other complication occurred in immediate connection with MRI. The follow-up time was 21.3 +/- 4.5 months. This small study shows no evidence of an MRI-related risk of stent-restenosis or other cardiovascular complications, not even if cardiac MRI is performed early after stent implantation.

Angioplasty, Balloon, Coronary↗

A semi-automated method to quantify left ventricular diastolic inflow propagation by magnetic resonance phase velocity mapping.

A new method of analysis was used for clinical magnetic resonance phase velocity mapping (PVM) to quantify propagation speed (PS) of early diastolic left ventricular (LV) inflow. A group of older volunteers (OV; n = 21, age 58+/-11 years) and a group of aortic stenosis patients (AS; n = 21, age 69+/-8 years) were studied. PVM was used to measure diastolic inflow in the LV outflow tract plane. PS was quantified by a semi-automated method (Auto) and by an operator (Manual). The mean+/-SD PS was 0.71+/-0.21 (Auto) and 0.67+/-0.23 (Manual) m/sec in the OV group, versus 0.49+/-0.28 (Auto) and 0.43+/-0.18 m/sec (Manual) in the AS group. There were no differences in peak transmitral E-wave (P = 0.70) between OV and AS. However, there were differences in PS-Auto (P = 0.0079) and PS-Manual (P = 0.0007) between the two groups. PS is a promising index for identifying diastolic LV dysfunction in AS patients. The semi-automated technique is a practical approach for quantifying LV filling.

Adult↗

Automatic vessel segmentation using active contours in cine phase contrast flow measurements.

The segmentation of images obtained by cine magnetic resonance (MR) phase contrast velocity mapping using manual or semi-automated methods is a time consuming and observer-dependent process that still hampers the use of flow quantification in a clinical setting. A fully automatic segmentation method based on active contour model algorithms for defining vessel boundaries has been developed. For segmentation, the phase image, in addition to the magnitude image, is used to address image distortions frequently seen in the magnitude image of disturbed flow fields. A modified definition for the active contour model is introduced to reduce the influence of missing or spurious edge information of the vessel wall. The method was evaluated on flow phantom data and on in vivo images acquired in the ascending aorta of humans. Phantom experiments resulted in an error of 0.8% in assessing the luminal area of a flow phantom equipped with an artificial heart valve. Blinded evaluation of the volume flow rates from automatic vs. manual segmentation of gradient echo (FFE) phase contrast images obtained in vivo resulted in a mean difference of -0.9 +/- 3%. The mean difference from automatic vs. manual segmentation of images acquired with a hybrid phase contrast sequence (TFEPI) within a single breath-hold was -0.9 +/- 6%.

Adult↗

Effects of temperature and histopathologic preparation on the size and morphology of atherosclerotic carotid arteries as imaged by MRI.

Using magnetic resonance imaging the effects of temperature, formalin fixation, and decalcification on the size and morphology of atherosclerotic arteries were evaluated. Ten ex vivo carotid arteries were scanned fresh at body and room temperature and formalin-fixed and decalcified at room temperature. Different spin-echo pulse sequences were used and absolute T2 values calculated. During processing for histopathology, the contrast between the arterial layers increased. From body to room temperature there were significant increases in size (4%-7%), T2 of media (60--> 68 msec), and fibrous plaque component (95--> 110 msec). Formalin fixation caused significant increases in size (2%-3%) and media T2 (68--> 74 msec). Decalcification caused significant shrinkage (2%-5%) and decrease in T2 of media (74--> 53 msec) and fibrous plaque component (118--> 76 msec). Thus temperature and preparation have profound effects on contrast, size, and T2 of atherosclerotic arteries. Ex vivo experiments should be performed on fresh specimens at body temperature. J. Magn. Reson. Imaging 1999;10:876-885.

Aged↗

Heart motion adapted cine phase-contrast flow measurements through the aortic valve.

A method for magnetic resonance cine velocity mapping through heart valves with adaptation of both slice offset and angulation according to the motion of the valvular plane of the heart is presented. By means of a subtractive labeling technique, basal myocardial markers are obtained and automatically extracted for quantification of heart motion at the valvular level. The captured excursion of the basal plane is used to calculate the slice offset and angulation of each required time frame for cine velocity mapping. Through-plane velocity offsets are corrected by subtracting velocities introduced by basal plane motion from the measured velocities. For evaluation of the method, flow measurements downstream from the aortic valve were performed both with and without slice adaptation in 11 healthy volunteers and in four patients with aortic regurgitation. Maximum through-plane motion at the aortic root level as calculated from the labeled markers averaged 8.9 mm in the volunteers and 6.5 mm in the patients. The left coronary root was visible in 2-4 (mean: 2.2) time frames during early diastole when imaging with a spatially fixed slice. Time frames obtained with slice adaptation did not contain the coronary roots. Motion correction increased the apparent regurgitant volume by 5.7 +/- 0.4 ml for patients with clinical aortic regurgitation, for an increase of approximately 50%. The proposed method provides flow measurements with correction for through-plane motion perpendicular to the aortic root between the valvular annulus and the coronary ostia throughout the cardiac cycle. Magn Reson Med 42:970-978, 1999.

Adult↗

Single breath-hold slice-following CSPAMM myocardial tagging.

Myocardial tagging has shown to be a useful magnetic resonance modality for the assessment and quantification of local myocardial function. Many myocardial tagging techniques suffer from a rapid fading of the tags, restricting their application mainly to systolic phases of the cardiac cycle. However, left ventricular diastolic dysfunction has been increasingly appreciated as a major cause of heart failure. Subtraction based slice-following CSPAMM myocardial tagging has shown to overcome limitations such as fading of the tags. Remaining impediments to this technique, however, are extensive scanning times (approximately 10 min), the requirement of repeated breath-holds using a coached breathing pattern, and the enhanced sensitivity to artifacts related to poor patient compliance or inconsistent depths of end-expiratory breath-holds. We therefore propose a combination of slice-following CSPAMM myocardial tagging with a segmented EPI imaging sequence. Together with an optimized RF excitation scheme, this enables to acquire as many as 20 systolic and diastolic grid-tagged images per cardiac cycle with a high tagging contrast during a short period of sustained respiration.

Adult↗

Quantitative abdominal aortic flow measurements at controlled levels of ergometer exercise.

Measuring the exercise-induced flow changes in the arteries of the body is a major challenge. The use of quantitative MR flow measurements for this purpose is hampered by movement artifacts and ECG triggering problems. To quantify exercise-induced flow changes in the abdominal aorta, we applied a fast hybrid phase contrast sequence with K-space segmentation and echo planar imaging readouts during a 12 heart beat, single breathhold post exercise scanning window after ergometer exercise in nine volunteers. Central k-space was acquired first. The changes in heart rate throughout the scanning window were quantified. The mean decrease in heart rate after six heart beats post exercise was less than 4% and less than 14% after 11 heart beats indicating that the exercise state was very well represented during the acquisition of central k-space. Abdominal aortic flow increased from 1.4+/-0.3 l/min at rest to 7.9+/-1.1 l/min at 131 watt. Retrograde flow reached a maximum value of 1.2 l/min at rest, and lasted 140 ms on average. Only for one out of the nine volunteers was there any retrograde flow present during exercise (at 33 watt and 65 watt exercise). It was concluded that retrograde flow patterns in the abdominal aorta associated with oscillating wall shear stresses and development of atherosclerosis disappeared with increasing levels of exercise. The feasibility of using fast quantitative phase contrast measurements during a post exercise scanning window to represent controlled exercise levels was demonstrated.

Adult↗

Age-dependent changes in spatial and temporal blood velocity distribution of early left ventricular filling.

This study describes early diastolic inflow dynamics based on three-directional magnetic resonance velocity data and investigates age-dependent changes in early diastolic inflow characteristics. We examined 26 young healthy volunteers age 25 (3) years (mean, SD), and 23 healthy older volunteers age 63 (8) years. Three-directional magnetic resonance velocity mapping was performed in a long axis plane through the heart. Transverse velocity profiles were read in five different positions in the early diastolic inflow stream of the left ventricle. The size and timing of the maximum velocities at each level were recorded and the repeatability of the method was tested. Compared with the younger group, the older group was characterized by: 1) lower maximum velocity in all positions, 2) increased deceleration of blood downstream from the mitral leaflet tips, and 3) delayed velocity propagation. The described method was repeatable and enabled detection of the age-dependent differences between groups of normal subjects. In conclusion, the early diastolic inflow pattern changes with age, probably reflecting changes in the diastolic function of the myocardium.

Adult↗

Prosthetic heart valve evaluation by magnetic resonance imaging.

OBJECTIVE: To evaluate the potential of magnetic resonance imaging (MRI) for evaluation of velocity fields downstream of prosthetic aortic valves. Furthermore, to provide comparative data from bileaflet aortic valve prostheses in vitro and in patients. METHODS: A pulsatile flow loop was set up in a 7.0 Tesla MRI scanner to study fluid velocity data downstream of a 25 mm aortic bileaflet heart valve prosthesis. Three dimensional surface plots of velocity fields were displayed. In six NYHA class I patients blood velocity profiles were studied downstream of their St. Jude Medical aortic valves using a 1.5 Tesla MRI whole-body scanner. Blood velocity data were displayed as mentioned above. RESULTS: Fluid velocity profiles obtained from in vitro studies 0.25 valve diameter downstream of the valve exhibited significant details about the cross sectional distribution of fluid velocities. This distribution completely reflected the valve design. Blood velocity profiles in humans were considerably smoother and in some cases skewed with the highest velocities toward the anterior-right ascending aortic wall. CONCLUSION: Display and interpretation of fluid and blood velocity data obtained downstream of prosthetic valves is feasible both in vitro and in vivo using the MRI technique. An in vitro model with a straight tube and the test valve oriented orthogonally to the long axis of the test tube does not entail fluid velocity profiles which are compatible to those obtained from humans, probably due to the much more complex human geometry, and variable alignment of the valve with the ascending aorta. With the steadily improving quality of MRI scanners this technique has significant potential for comparative in vitro and in vivo hemodynamic evaluation of heart valves.

Adult↗

Bancroftian filariasis in an irrigation project community in southern Ghana.

An epidemiological study to document the endemicity and transmission characteristics of bancroftian filariasis was conducted in an irrigation project community in southern Ghana. In a 50% random sample of the population, the prevalence of microfilaraemia was 26.4% and the geometric mean microfilarial intensity among positives was 819 microfilariae/ml of blood. Hydrocoele was found in 13.8% of the males aged > or =18 years, and 1.4% of the residents examined, all females, had tymphoedema/elephantiasis. Detailed monitoring of the microfilarial intensity in 8 individuals over a 24-h period confirmed its nocturnal periodicity with a peak at approximately 0100 hours. The most important vector was Anopheles gambiae s.l., followed by An. funestus. The abundance of these mosquitoes and their relative importance as vectors varied considerably between the wet and the dry season. Opening of the irrigation canals late in the dry season resulted in a remarkable increase in the population of An. gambiae (8.3% of which carried infective filarial larvae) to levels comparable to those seen during the wet season, suggesting that the irrigation project is responsible for increased transmission of lymphatic filariasis in the community.

Adolescent↗

Bancroftian filariasis on Pemba Island, Zanzibar, Tanzania: an update on the status in urban and semi-urban communities.

Cross-sectional clinical, parasitological and entomological surveys for bancroftian filariasis were conducted in Konde, Chake Chake and Kengeja, three urban and semiurban communities on Pemba Island, and the results were compared with similar surveys done 15 years earlier. The overall prevalences of clinical manifestations among males aged 15 years or more (n = 614) was remarkably similar to those recorded 15 years earlier: elephantiasis 1.4% in 1975 and 1.1% in 1990; hydrocele, 22.4% and 21.8%, respectively. However, when the communities were compared individually, there was a reduction in the hydrocele prevalence in Konde from 22.4% to 11.5% and an increase in Kengeja from 27.0% to 35.5%. The overall microfilarial prevalence found during night blood surveys of all individuals aged 1 year or more (n = 2687) was 9.7%, compared to 14.2% recorded in 1975. The reduction was most pronounced in Konde. Of 1052 female mosquitoes caught with CDC light traps, 95% were Culex quinquefasciatus and 5% Anopheles gambiae s.l. Infective larvae of Wuchereria bancrofti were found only in the former. The filariasis situation in urban and semiurban communities on Pemba Island appears not to have changed considerably over the last 15 years.

Adolescent↗