PubMed Health⌕ Search

Biomedical subjects

E Machtejevas

Publications and source records attributed to E Machtejevas.

4 recordsLinked to original sources

Sulphonic acid strong cation-exchange restricted access columns in sample cleanup for profiling of endogenous peptides in multidimensional liquid chromatography. Structure and function of strong cation-exchange restricted access materials.

In this work, the pore structural parameters and size exclusion properties of LiChrospher strong cation-exchange and reverse phase restricted access materials (RAM) are analysed. The molecular weight size exclusion limit for polystyrenes was found to be about 17.7 kDa, while for standard proteins, the molecular weight size exclusion limit was higher, at approximately 25 kDa. The average pore diameter on a volume basis calculated from the pore network model changes from 8.5 nm (native LiChrospher) to 8.6 nm (diol derivative) to 8.2 nm (sulphonic acid derivative) to 6.9 nm (n-octadecyl derivative). Additional characterisations were performed on restricted access materials with nitrogen sorption at 77 K, water adsorption at 25 degrees C, intrusion-extrusion of water (in order to evaluate the hydrophobic properties of the pores of the hydrophobic RAM), and zeta potential measurements by microelectrophoresis. For peptide analysis out of the biofluids, the strong cation-exchange functionality seems to be particularly suitable mainly because of the high loadability of the strong cation-exchange restricted access material (SCX-RAM) and the fact that one can work under non-denaturing conditions to perform effective chromatographic separations. For bacitracin, the dynamic capacity of the SCX-RAM columns does not reach its maximum value in the analysed range. For lysozyme, the dynamic capacity reaches a value of 0.08 mg/ml of column volume before column is overloaded. Additionally, the proper column operating conditions that lead to the total effective working time of the RAM column to be equal to approximately 500 injections (depending on the type of sample), is comprehensively described. The SCX-RAM column was used in the same system analysing urine samples for the period of 1 month (approximately 150 injections) with run-to-run reproducibility below 5% RSD and below 10% RSD for the relative fractions.

Cation Exchange Resins↗

Selective protein removal and desalting using microchip CE.

This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sample preconcentration and sample clean-up, while in the second channel the selected compounds are separated. Isotachophoresis (ITP) combined with zone electrophoresis (CZE) was used to preconcentrate a myoglobin sample by a factor of about 65 before injection into the second dimension and to desalt a mixture of six proteins with 100 mM NaCl. However, ITP-CZE could not be used for the removal of two proteins from a protein/peptide sample since the protein zone in the ITP step was too small to remove certain compounds. Therefore, we used CZE-CZE for the removal of proteins from a protein/peptide mixture, thereby injecting only the peptides into the second CZE separation channel.

Animals↗

Synthesis and characterization of polyrotaxane-based polymeric continuous beds for capillary electrochromatography.

The continuous bed technique with its attractive features, such as fritless design, one-step in situ synthesis, low back pressure and no need for pressurising the electrode vessels to suppress bubble formation was applied to form polyrotaxane-based stationary phases for capillary electrochromatography (CEC). Rotaxanes are synthesized from two classes of substances, namely linear reactive monomers and inert cyclic compounds. Upon polymerisation, a gel forms with the cyclic molecules mechanically immobilized (see Fig. 1). We have employed this simple approach, using charged derivatives of cyclodextrins in order to introduce charged groups into continuous beds and thus render them appropriate for electrochromatography. The self-assembly of supramolecular structures to form rotaxanes during the synthesis of the continuous beds is treated. The electroosmotic and chromatographic properties of the various polyrotaxane-based stationary phases synthesized are discussed, as well as the synthesis of the continuous beds, including how to affect their porosity and its influence on the efficiency of the electrokinetic separation. The applicability of the rotaxane-based continuous bed is demonstrated by separation of model compounds by reversed- and normal-phase chromatography. A separation of enantiomers is also presented. This experiment is of particular interest because it indicates that the interaction with the cavity of beta-cyclodextrin (beta-CD) is not a fundamental requirement for enantioseparations.

Chromatography, Micellar Electrokinetic Capillary↗

Chiral separation of amino acids by ligand-exchange capillary electrochromatography using continuous beds.

A chiral ligand-exchange phase for capillary electrochromatography based on continuous bed technology was developed. The chiral stationary phase is prepared by a one-step in situ copolymerization procedure using methacrylamide, piperazine diacrylamide, vinylsulfonic acid and N-(2-hydroxy-3-allyloxypropyl)-L-4-hydroxyproline. These chiral continuous beds are inexpensive and easy to prepare. They also have several advantages over silica-based packed capillaries. Since the bed is covalently attached to the capillary wall, no frit is required. The applicability of this new approach to the chiral separation of underivatized amino acids is demonstrated.

Amino Acids↗