PubMed HealthSearch

Biomedical subjects

E Matsuo

Publications and source records attributed to E Matsuo.

At least 19 recordsLinked to original sources

[Brain metastasis from primary pericardial mesothelioma. Case report].

A 50-year-old female was admitted because of nausea, vomiting, and cerebellar ataxia. Computed tomography scan revealed an enhanced mass accompanied with a cyst in the right cerebellar hemisphere. The mass situated in the subcortical region was removed. Histologically, highly vascular tumor cells lined the cavities. Postoperative radio- and chemotherapy were administered and the clinical symptoms improved gradually. Two months later, the patient complained of dyspnea. Chest X-ray on second admission demonstrated cardiomegaly. Hemorrhagic pericardial effusion amounting to 1000 ml was aspirated by pericardial puncture. Papillary clusters of tumor cells were demonstrated in the pericardial effusion. The patient died of cardiac failure. At necropsy solid tumors were located in the heart, lung, left inguinal region, and cerebellum. Histological diagnosis was mesothelioma arising from the heart. Primary pericardial mesotheliomas are rare; approximately 106 cases have been reported. Pericardial mesothelioma frequently spreads to the adjacent pleura and mediastinum, but distant metastases are extremely rare because patients with pericardial mesothelioma tend to die early due to cardiac failure or cardiac tamponade.

Brain Neoplasms

A study on the impression materials using for the mannequin practice.

The mannequin exercises which are practiced in clinical exercises of dental colleges are getting more important these days. It is necessary to compare the difference between the efficiency of a mannequin and a living body. When making a partial denture using the simulation model, it is very important to know what kind of impression materials you are able to use or the accuracy of those impression materials. A study on a simulation model is used for making a partial denture. Choosing some sort of impression materials and treatment positions have the possibility to exert influence on impression taking through the process from impression taking to model making. At first, to find the impression materials which are able to take the impression of simulation model's simulate mucous membrane, choose nine impression materials and examined them. Then, examine the effective relationship between the impression taking and the mannequin's head and back position. Establish a mannequin's head and back inclination from four positions. Cut the acquired four models at the same location and examine them. The following results were obtained. 1. Of the impression materials used, with the exception of Flexicon and Rapid, there was no adhesiveness observed with the artificial mucosa. In addition, in the case of Exaflex Injection, Regular and Putty, there were noninduration sections among the sections that contacted with the artificial mucosa. 2. Regarding the effect of the bodily position, changes in the impression were observed for the upper jaw in the case of the median sagittal section C and the lateral section S. This was particularly frequent on the palate in the molar region.(ABSTRACT TRUNCATED AT 250 WORDS)

Dental Impression Materials

[A study of linearity and reciprocity during shock applied with a hammer to human dry skull].

The authors used a human dry skull on which the cranial bone mandible had been joined with an artificial articulator disk to form a single unit. Impact acceleration corresponding to weak and strong tapping was considered a dynamic load in examining the vibration transfer characteristics of the facial cranial bone when impact was applied from the mentum section in a situation designed to be closer to reality. Flexion injection type (resonance frequency f0 = 100 to 150 Hz, produced by GC Corp.) was applied to the human dry skull as an artificial periodontal membrane at thickness of 0.3 mm. In addition, Exaflex heavy body type (f0 = 400 Hz, produced by GC Corp.) was applied as an artificial disk. This was then placed on a damper produced by spreading a rubber dam sheet with a thickness of 35 microns on a tire tube with a diameter of 35 cm and an air pressure of 35 kg/cm2. Investigations were then made concerning linearity and reciprocity to determine whether an experimental system could be achieved or not. This was then followed by modal analysis. As a result, the following matters were ascertained: (1) The resonating area differed according to the extent of the force. (2) An increase in the viscoelastic elements of the silicon was accompanied by attenuation of force. (3) Directionality of force attenuation was caused by the complexity of bone structure. (4) A tapping force of 0.3G or 1G was sufficiently attenuated by the facial cranial bone. (5) The transfer function at the bone seams and thinner areas of the bones was insufficient for modal analysis of the facial region and total cranial bone of the human dry skull.

Biomechanical Phenomena

Highly sensitive enzyme immunoassay of human interferon-beta 1.

A highly sensitive sandwich enzyme immunoassay for human interferon-beta 1 (HuIFN-beta 1) was developed. HuIFN-beta 1-containing samples and horseradish peroxidase (HRP)-labeled mouse anti-HuIFN-beta 1 monoclonal antibody (Fab') were incubated overnight at 2-10 degrees C in the wells of a 96-well microtiter plate, onto which affinity-purified rabbit anti-HuIFN-beta 1 polyclonal antibody was coated. The EIA was able to detect 0.5 IU/ml of HuIFN-beta 1, thus showing higher sensitivity than bioassay. The values obtained by the EIA closely paralleled those obtained by bioassay in the concentration which bioassay can detect. In order to detect the concentration below 0.5 IU/ml of HuIFN-beta 1, the avidin/biotin-amplified EIA was also developed. The use of biotinylated mouse anti-HuIFN-beta 1 monoclonal antibody (F(ab')2) and HRP-avidin in the EIA made it possible to detect 0.1 IU/ml of HuIFN-beta 1. These EIAs were applied for the studies such as process control of HuIFN-beta 1 production, pharmacokinetics of HuIFN-beta 1, and determination of serum level of HuIFN-beta 1 in healthy subjects.

Antibodies, Monoclonal

[Observation with SEM on the displacement of mucosal surface in process of denture fabrication].

The process of denture fabrication entails a series of steps that begin with impression-taking. Dimensional accuracy and displacement of surface repeatability affect results in these individual steps. Although changes in individual materials have already been measured in the past, there has been almost no measurement up to now of denture fabrication up to the denture base, using the mucous membrane as the standard and then measuring changes in the displacement of surface repeatability for each step. Noticing this lack, the authors used a Scanning Electron Microscope (SEM), presently the only non-contact measuring instrument that can be used, and measured changes at the different stages including the mucous membrane, the impression materials, the plaster and the resin. A drying process is required for the mucous membrane, and such a process can cause changes in the mucous membrane which is the basis of measurement. For this reason, the authors used Araldite, a product from Ciba-Geigy AG, as a replica material and made replicas for all the test materials, using the replicas for measurement. Results were as follows: 1. Araldite was used as the replica material, thus making it possible with the SEM to observe changes in the displacement of surface repeatability at the individual stages. 2. Major changes in the accuracy of surface were observed during impression-taking and in the period of moving from the impression material to the plaster. 3. During high-power observation with the SEM, the fine bumps on the surface of the plaster and resin disappeared and the surfaces became smooth. This is believed to be the result of the separating agent and heat.

Dental Impression Materials

[Clinical experience with cefmenoxime (CMX) in complicated urinary tract infections].

Cefmenoxime (CMX) was intravenously administered to 106 patients with complicated urinary tract infection at a daily dose of 2-4 g for 5 days. An excellent response in overall clinical efficacy was seen in 15 cases (18.3%), a moderate response in 46 cases (56.1%) and poor response in 21 cases (25.6%). Pyuria was cleared in 20 cases (24.4%), decreased in 22 cases (26.8%) and unchanged in 40 cases (48.8%). Bacteriuria was eliminated in 41 cases (50.0%), decreased in 17 cases (20.7%), relapsed in 7 cases (8.5%) and unchanged in 17 cases (20.7%). Bacteriologically, 74 (76.8%) of the 95 strains isolated were eradicated by CMX, and 22 (23.2%) persisted. Side effects were observed in 3 (abdominal pain, diarrhea and elevation of trans amylase) of the 106 cases. Judging from the above results, CMX is considered to be a useful drug in the treatment of complicated urinary tract infections.

Adolescent