PubMed Health⌕ Search

Biomedical subjects

E Monson

Publications and source records attributed to E Monson.

7 recordsLinked to original sources

The impact of external beam radiation therapy prior to autologous bone marrow transplantation in patients with non-Hodgkin's lymphoma.

External beam radiation therapy (XRT) is frequently used to treat refractory disease sites or consolidate remission in patients with relapsed non-Hodgkin's lymphoma (NHL) prior to autologous bone marrow transplantation (ABMT). We report the long-term outcome and toxicities associated with this therapy. We uniformly treated 552 patients with NHL with total body irradiation, high-dose chemotherapy, and anti-B-cell monoclonal antibody-purged ABMT. Of these patients, 152 received XRT to the mediastinum, abdomen, or pelvis (n = 102) or other sites (n = 50) prior to ABMT. In this nonrandomized series, there was no difference in progression-free survival between patients treated with XRT and those not treated with XRT. For patients with indolent histology, there was no difference in overall survival between patients treated with XRT and those not treated with XRT. For patients with aggressive histology, the median overall survival time was 64 months in the XRT patients and 79 months in the patients not treated with XRT (P= .09). The risk of acute transplantation-related deaths was not influenced by prior XRT (P = .68). Of patients who received XRT, 12.5% developed secondary myelodysplasia compared with 5.8% of patients not receiving XRT (P = .01). Patients receiving XRT to the mediastinum or axilla had a significantly higher risk of late respiratory death (P = .002). In conclusion, XRT allows refractory patients to become eligible for transplantation and experience a disease-free survival interval equivalent to that of patients who do not receive XRT. However, a higher incidence of non-relapse-associated deaths was observed in patients who received XRT. Future work should explore alternative conditioning strategies and altered timing of XRT, in an attempt to limit these late toxicities.

Adult↗

Observation of laser speckle effects and nonclassical kinetics in an elementary chemical reaction.

An experimental demonstration is provided for memory-based, nonclassical reaction kinetics in a homogeneous system with an elementary reaction, A+B-->C. A new reaction-kinetics regime is observed which is a direct consequence of speckles in the laser beam. However, in spite of the nonrandom, speckled initial distribution of reactant B, the long-time regime gives the first experimental demonstration of the asymptotic self-segregation ("Zeldovich") effect. Monte Carlo simulation results are consistent with the experiments.

Journal Article↗

Lifetime enhancement of ultrasmall fluorescent liquid polymeric film based optodes by diffusion-induced self-recovery after photobleaching.

The major concern with optodes, especially miniaturized ones, has been their photobleaching limited lifetime. Liquid polymer [highly plasticized poly(vinyl chloride)] films are commonly used to prepare fluorescent optical fiber sensors. A major advantage is the ease of their fabrication. It is demonstrated here that, with proper choice of excitation power and illumination time, the sensor will completely recover itself from photobleaching after each measurement. This self-recovery is demonstrated on single-mode optical fibers with 80 microns diameter (3.1 microns active region) and on near-field scanning optical microscope pulled fiber tips with submicrometer diameter (250 nm active region). The single-mode optode can be used for 30,000 measurements with only a 5% signal loss at a signal/noise of > 66. This opens the way for prolonged ratiometric application of such optodes.

Diffusion↗

Implementation of an NSOM system for fluorescence microscopy.

We describe our progress toward an NSOM system intended for fluorescence imaging of biological samples. This process included integration of shear-force feedback into an existing NSOM system. Topographic images acquired using uncoated tips are presented. We also present our initial effort at simultaneous acquisition of topographic and fluorescence data using an aluminum coated tip.

Equipment Design↗