PubMed Health⌕ Search

Biomedical subjects

E N Sobol

Publications and source records attributed to E N Sobol.

5 recordsLinked to original sources

Theramal, mechanical, optical, and morphologic changes in bovine nucleus pulposus induced by Nd:YAG (lambda = 1.32 microm) laser irradiation.

UNLABELLED: BACKGROUND AND OBJECTIVE To examine the biophysical effects of photothermal heating on herniated intervertebral discs during laser decompression surgery. STUDY DESIGN/MATERIALS AND METHODS: Ex vivo bovine nucleus pulposus specimens were irradiated with a Nd: YAG laser (lambda = 1.32 microm, 100 seconds exposure time, 9-31 W/cm(2), 4.8 mm spot diameter), whereas changes in tissue thermal, mechanical, and optical properties were monitored by using, respectively, infrared radiometry, tissue tension measurements, and diffuse reflectance from a HeNe probe laser. Morphologic changes and mass reduction were monitored by recording shape changes on video and weighing specimens before and after laser exposure. RESULTS: At power densities below 20 W/cm(2), evaporation of water and specimen volume reduction (shrinking) were consistently observed on video during irradiation. In contrast, above 20 W/cm(2), vapor bubbles formed within the specimen matrix and subsequently ruptured (releasing heated vapors). When radiometric surface temperature approaches approximately 60 to 70 degrees C (denaturation threshold for tissue), tissue tension begins to increase, which is consistent with observations of specimen length reduction. The onset of this change in tissue tension is also reflected in characteristic alterations in diffuse reflectance. With cessation of laser irradiation, a sustained increase in tissue tension is observed, which is consistent with changes in specimen length and volume. Higher laser power results in a faster heating rate and subsequently an accelerated tension change. Specimen mass reduction increased with irradiance from 19 to 72% of the initial mass for 9--31 W/cm(2), respectively. Irradiated specimens did not return to their original shape after immersion in saline (48 hours) in contrast to air-dried specimens (24 hours), which returned to their original shape and size. CONCLUSION: These observations suggest that photothermal heating results in irreversible matrix alteration causing shape change and volume reduction (observed on video and evidenced by the increase in tissue tension) taking place at approximately 65 degrees C. Inasmuch as high laser power results in vapor bubble formation and specimen tearing, the heating process must be controlled. Diffuse reflectance measurements provide a noncontact, highly sensitive means to monitor dynamically changes in tension of nucleus purposus.

Animals↗

Proteoglycan synthesis in porcine nasal cartilage grafts following Nd:YAG (lambda = 1.32 microns) laser-mediated reshaping.

Mechanically deformed morphologic cartilage grafts undergo temperature-dependent stress relaxation during sustained laser irradiation resulting in stable shape changes. In this study, porcine nasal septal cartilage specimens were evaluated for viability by measuring the incorporation of Na2(35)SO4 into proteoglycan (PTG) macromolecules in whole tissue culture following laser-mediated reshaping. Synthesis rates of PTG were determined by scintillation counting lyophilized specimens and normalizing these values by total protein content. Positive controls were established by inducing chondrocyte apoptosis using prolonged exposure to nitric oxide (NO). In chondrocytes, apoptosis induced using NO resulted in significantly lower PTG synthesis rates compared to untreated native specimens. Cartilage specimens were irradiated with light emitted from a Nd:YAG laser (25 W/cm2, lambda = 1.32 microns) while recording simultaneously radiometric surface temperature, internal stress and back-scattered light intensity from a probe laser. Each specimen received one, two or three sequential laser exposures. The duration of each exposure was determined from real-time measurements of characteristic changes in back-scattered light intensity that correlate with accelerated stress relaxation. A 5 min time interval between each laser exposures allowed the cartilage specimen to return to thermal equilibrium. Average PTG synthesis rates decreased with successive laser exposures, though these were always higher than baseline rates established for NO-treated tissues, suggesting that laser-mediated cartilage reshaping acutely does not eliminate the entire population of viable chondrocytes. The reduction in PTG synthesis is correlated with the time-temperature-dependent heating profile created during laser irradiation, supporting our hypothesis that careful monitoring of laser dosimetry is required to ensure chondrocyte viability.

Animals↗

Thermal and diffusion processes in laser-induced stress relaxation and reshaping of cartilage.

The thermodynamic characteristics of the 'bound-to-free' phase transformation of water are studied by means of differential microcalorimetry and FTIR spectroscopy. This phase transition controls the stress relaxation and reshaping of cartilage which we have observed previously under moderate laser heating. It is shown that the FTIR spectrum of bound water in cartilage differs from that of free water in cartilage, and that both show differences to the FTIR spectrum of pure water. The proportion of bound water in cartilage is found to be of the order 4%. We have examined water liberation and absorption kinetics and found them to be controlled by diffusion through the tissue and also by the bound-to-free water transformation. The theoretical modelling and experimental data allowed calculation of diffusion coefficients and the activation energy for water transfer. The latter was found to be close to the heat of phase transformation of water. We have established that the drying and wetting processes in cartilage are reversible (fully or in a part, depending on the temperature of preliminary drying) and can be described by identical solutions of the diffusion problem, with coefficients of water diffusion being the same. The mechanism of water diffusion in cartilaginous tissue is also discussed.

Animals↗

Atomic force microscopic study of the surface morphology of apatite films deposited by pulsed laser ablation.

Atomic force microscopy (AFM) has been used to study the surface morphology of apatite films deposited on metallic and polyethylene substrates by laser ablation using KrF and transversely excited atmospheric CO2 lasers. The films are found to consist of a smooth apatite coating with macroparticles scattered on the surface. A wide variety of macroparticles, differing in size, shape and roughness, were found and analysed employing the high spatial resolution of AFM (< 1 nm). We have investigated the correlation between the apatite film morphology and the deposition conditions. Of particular importance are laser fluence, gas pressure, the nature of the target and the substrate temperature. We have explained these dependencies on the basis of a theoretical model which includes evaporation and a cluster-type laser ablation mechanism.

Apatites↗

Feedback-controlled laser-mediated cartilage reshaping.

OBJECTIVE: To demonstrate feedback-controlled laser-mediated cartilage reshaping using dynamic measurements of tissue optical properties and radiometric surface temperatures. DESIGN: Flat cartilage specimens were reshaped into curved configurations using a feedback-controlled laser device. MATERIALS: Fresh porcine nasal septum, stripped of perichondrium and cut into uniform strips (25 x 10 x 1.5-2.1 mm) with a custom guillotine microtome. INTERVENTIONS: Cartilage specimens secured in a cylindrical reshaping jig (2.5 cm in diameter) and irradiated with an Nd:YAG laser (lambda = 1.32 microns, 25 W/cm2, 50-Hz pulse repetition rate). During laser irradiation, radiometric surface temperature was measured along with changes in forward-scattered light from a diode probe laser (lambda = 650 nm, 5 mW), using a lock-in detection technique. Sequential irradiation of the specimen outer surface was made (3 laser passes). Characteristic changes in tissue temperature and light-scattering signals were used to terminate laser irradiation. RESULTS: Effective reshaping was accomplished for both thin (1.5-mm) and thick (2.1-mm) specimens. Following reshaping, specimens were stored in saline solution at 4 degrees C for 21 days. No return to the original flat configuration was noted during this period. CONCLUSIONS: The prototype device effectively reshapes flat native porcine cartilage into curve configurations. The use of optical and thermal signals provides effective feedback control for optimizing the reshaping process.

Animals↗