Interaction between fascicle and tendinous tissues in short-contact stretch-shortening cycle exercise with varying eccentric intensities.

The interaction between fascicle and tendinous tissues (TT) in short-contact drop jumps (DJ) with three different drop heights [low (Low), optimal (OP), and high (High)] was examined with 11 subjects. The ground reaction force (F(z)) and ankle and knee joint angles were measured together with real-time ultrasonography (fascicle length) and electromyographic activities of the medial gastrocnemius (MG) and vastus lateralis (VL) muscles during the movement. With increasing drop height, the braking force and flight time increased from Low to OP (P < 0.05). In High, the braking force increased but the flight time decreased compared with OP (P < 0.05). During contact of Low and OP conditions, the length of muscle-tendon unit and TT underwent lengthening before shortening in both MG and VL muscles. However, the two muscles differed in the fascicle behaviors. The MG fascicles behaved isometrically or shortened, and the VL fascicles underwent lengthening before shortening during contact. In High, the TT lengthening in both muscles decreased compared with OP (P < 0.05). The rapid stretch occurred in the MG fascicles but not in VL fascicles during the braking phase. The elastic recoil ratio decreased in both muscles with increasing the intensity during DJ. These findings demonstrated that TT underwent lengthening before shortening during DJ. However, the efficacy of elastic recoil decreased with increasing the drop intensity. The effective catapult action in TT can be limited by the drop intensity. In addition, the measured muscles behaved differently during DJ, providing evidence that each muscle may have a specific means of fascicle-TT interaction.

Adult↗

Bone healing and mineralization, implant corrosion, and trace metals after nickel-titanium shape memory metal intramedullary fixation.

Its shape memory effect, superelasticity, and good wear and damping properties make the NiTi shape memory alloy a material with fascinating potential for orthopedic surgery. It provides a possibility for making self-locking, self-expanding, and self-compressing implants. Problems, however, may arise because of its high nickel content. The purpose of this work was to determine the corrosion of NiTi in vivo and to evaluate the possible deleterious effects of NiTi on osteotomy healing, bone mineralization, and the remodeling response. Femoral osteotomies of 40 rats were fixed with either NiTi or stainless steel (StSt) intramedullary nails. The rats were killed at 2, 4, 8, 12, 26, and 60 weeks. Bone healing was examined with radiographs, peripheral quantitative computed tomography, (pQCT) and histologically. The corrosion of the retrieved implants was analyzed by electron microscopy (FESEM). Trace metals from several organs were determined by graphite furnace atomic absorption spectrometry (GF-AAS) or by inductively coupled plasma-atomic emission spectrometry (ICP-AES). There were more healed bone unions in the NiTi than in the StSt group at early (4 and 8 weeks) time points. Callus size was equal between the groups. The total and cortical bone mineral densities did not differ between the NiTi and StSt groups. Mineral density in both groups was lower in the osteotomy area than in the other areas along the nail. Density in the nail area was lower than in the proximal part of the operated femur or the contralateral femur. Bone contact to NiTi was close. A peri-implant lamellar bone sheet formed in the metaphyseal area after 8 weeks, indicating good tissue tolerance. The FESEM assessment showed surface corrosion changes to be more evident in the StSt implants. There were no statistically significant differences in nickel concentration between the NiTi and StSt groups in any of the organs. NiTi appears to be an appropriate material for further intramedullary use because it has good biocompatibility in bone tissue.

Animals↗

Bone modeling and cell-material interface responses induced by nickel-titanium shape memory alloy after periosteal implantation.

The purpose of this study was to evaluate the new bone formation, modeling and cell-material interface responses induced by nickel-titanium shape memory alloy after periosteal implantation. We used a regional acceleratory phenomenon (RAP) model, in which a periosteal contact stimulus provokes an adaptive modelling response. NiTi has thermal shape memory and superelasticity properties uncommon in other implant alloys. So far, there are insufficient data concerning the biocompatibility of NiTi as a bone implant. NiTi was compared to stainless steel (stst) and Ti-6Al-4V. The test implant was placed in contact with the intact femur periosteum, but it was not fixed inside the bone. Histomorphometry with digital image analysis was used to determine the bone formation and resorption parameters. The ultrastructural features of cell-material adhesion were analysed with scanning electron microscopy (FESEM). A typical peri-implant bone wall modelation was seen due to the normal RAP. The maximum new woven bone formation started earlier (2 weeks) in the Ti-6Al-4V group than in the NiTi (P < 0.01) group, but also decreased earlier, and at 8 weeks the NiTi (P < 0.05) and stst (P < 0.005) groups had greater cortical bone width. At 12 and 26 weeks no statistical differences were seen in the histomorphometric values. The histological response of the soft tissues around the NiTi implant was also clearly non-toxic and non-irritating. Cell adhesion and focal contacts were similar between the materials studied by FESEM. We conclude that NiTi had no negative effect on total new bone formation or normal RAP after periosteal implantation during a 26-week follow-up.

Alloys↗

In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: muscle and perineural tissue responses and encapsule membrane thickness.

Nickel-titanium shape memory alloy (Nitinol) has properties that could be very useful in surgical applications. Thermal shape memory, superelasticity, and high damping properties make such alloys behave differently compared to other implant metals. There has previously been a lack of sufficient evidence on the biocompatibility of Nitinol. The purpose of this study was to evaluate general soft tissue response and biocompatibility to Nitinol in vivo, and to clarify neural and perineural responses, previously unreported. Seventy-five rats were randomized into three groups. Test specimens were implanted into paravertebral muscle and near the sciatic nerve. A comparison was made between Nitinol, stainless steel, and Ti-6Al-4V. The animals were euthanized at 2, 4, 8, 12, and 26 weeks after implantation. General morphologic and histologic observations were made under light microscopy. Semiautomatic computerized image analysis was used to measure the encapsule membrane thickness around the implants. The muscular tissue response to Nitinol was clearly nontoxic, regardless of the time period. The overall inflammatory response to Nitinol was very similar to that of stainless steel and Ti-6Al-4V alloy. There were no necroses, granulomas, or signs of dystrophic soft tissue clacification. The immune cell response to Nitinol remained low. Only a few foreign-body giant cells were present. The detected neural and perineural responses were also clearly nontoxic and nonirritating with Nitinol. No qualitative differences in histology between the different test materials could be seen. At 8 weeks, the encapsule membrane of Nitinol was thicker than that of stainless steel (mean 62 +/- 25 microns vs. 41 +/- 8 microns). At the end of the study, the encapsule thickness was equal to all the materials tested. We concluded that Nitinol had good in vivo biocompatibility after intramuscular and perineural implantation in rats in the 26-week follow-up. Based on the results of the present study, Nitinol appears to have good potential for clinical use.

Animals↗

Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures.

Nickel-titanium alloy (Nitinol) is a metallic biomaterial that has a unique thermal shape memory, superelasticity, and high damping properties. Nitinol is potentially very useful in orthopedic surgery, for example. At present, there are not enough confirmative biocompatibility data available on Nitinol. The aim of our study was to clarify the primary cytotoxicity and corrosion rate of Nitinol in human cell cultures. Comparisons were made with stainless steel (Stst), titanium (Ti), composite material (C), and control cultures with no test discs. Human osteoblasts (OB) and fibroblasts (FB) were incubated for 10 days with test discs of equal size, 6 x 7 mm. The cultures were photographed and the cells counted. Samples from culture media were collected on days 2, 4, 6, and 8, and the analysis of metals in the media was done using flameless atomic absorption spectrophotometry. The proliferation of FB was 108% (Nitinol), 134% (Ti) (p < 0.02), 107% (Stst), and 48% (C)(p < 0.0001) compared to the control cultures. The proliferation of OB was 101% (Nitinol), 100% (Ti), 105% (Stst), and 54% (C) (p < 0.025) compared to the controls. Initially, Nitinol released more nickel (129-87 micrograms/L) into the cell culture media than Stst (7 micrograms/L), but after 2 days the concentrations were about equal (23-5 micrograms/L versus 11-1 micrograms/L). The titanium concentrations from both Nitinol and Ti samples were all < 20 micrograms/L. We conclude that Nitinol has good in vitro biocompatibility with human osteoblasts and fibroblasts. Despite the higher initial nickel dissolution, Nitinol induced no toxic effects, decrease in cell proliferation, or inhibition on the growth of cells in contact with the metal surface.

Biocompatible Materials↗

Pancreatic phospholipase A2 (PPLA2) during human pregnancy.

Pancreatic phospholipase A2 in human serum during pregnancy is within the normal range. In the amniotic fluid, the amount of immunoreactive pancreatic phospholipase A2 increases from 1.3 microgram/l at 16 weeks to 2.9 micrograms/l near term, but does not correlate with PLA2-activity. Meconium-stained amniotic fluid had highly elevated pancreatic, but not kinetic, PLA2. The fetal pancreas and its high PLA2-content may contribute to the progressive increase in uterine activity during human pregnancy.

Amniotic Fluid↗