PubMed Health⌕ Search

Biomedical subjects

E Olea

Publications and source records attributed to E Olea.

36 records · Page 2Linked to original sources

[Diagnosis of gastroesophageal reflux by radioisotopic techniques].

We evaluated 148 patients (mean age 45 years) with clinically evident gastroesophageal reflux. A radioisotopic test with 99mTc sulphur-colloid was performed in all; endoscopy in 146, biopsy in 24, acid reflux test and manometric evaluation in 141 and radiologic studies in 85. Sensitivity of the different techniques was: radioisotopes 92%, radiology 87%, acid reflux test 84%; endoscopy 63% and manometric studies 61%. Severity of reflux and esophagitis was adequately predicted from radioisotopic evaluation. We conclude that this radioisotopic test is highly reliable for the diagnosis of gastroesophageal reflux.

Adolescent↗

Comparison of electrocardiography and thallium-201 myocardial scintigraphy for the detection of ergonovine-induced coronary artery spasm: angiographic correlation.

This study was performed to determine the sensitivity of thallium imaging vs ECG monitoring for detecting coronary artery spasm noninvasively following intravenous ergonovine administration as compared to simultaneous coronary angiography. Thirty-two patients with insignificant coronary artery disease and chest pain underwent 12-lead ECG monitoring, thallium imaging, and coronary arteriography following the administration of 0.05, 0.1, 0.2, and 0.3 mg of ergonovine given 5 minutes apart or until chest pain occurred. One minute following the last dose of ergonovine, 2.5 mCi of thallium-201 was injected intravenously, and a final ECG was recorded and repeat coronary arteriography performed. Within 10 minutes following the injection of thallium, imaging was performed in the 40-degree and 70-degree left anterior oblique and anterior projections. The ECG, thallium study, and coronary arteriogram were read blindly and results were compared. The ECG, angiogram, and thallium study were read as positive if the following occurred, respectively: greater than or equal to 1 mm ST segment elevation, depression, or T wave reversal; greater than 50% vessel narrowing,; and reversible perfusion defect. Five patients were excluded from analysis because of either catheter-induced spasm, suboptimal thallium studies, or protocol violations. Of the 27 patients included for analysis, six had chest pain, five had a positive angiogram, five had a positive thallium study, and one had a positive ECG. The sensitivity of thallium vs ECG monitoring was 80% vs 25%, and the accuracy was 92% vs 80%. We conclude that thallium imaging greatly increases the noninvasive detection of ergonovine-induced coronary spasm as compared with the ECG with no loss of accuracy.

Adult↗

Gastroduodenal artery aneurysm detected by radionuclide studies.

A patient with gastroduodenal artery aneurysm detected with Tc-99m scintiangiography is described. Liver and hepatobiliary imaging were also performed on the patient. Ultrasound examination, arteriography, and surgical exploration were carried out. The value of radionuclide studies in leading to the proper diagnosis is emphasized.

Aged↗

Radionuclide synthetic Fourier images of cardiac wall motion abnormalities.

At present, the phase images together with amplitude images are used in nuclear medicine to aid the diagnosis of cardiac regional wall motion abnormalities (RWMA). The phase images represent the spatial distribution of the relative phase of the first harmonic fit of pixel time activity curves, and the amplitude images represent the distribution of the amplitude of the fit. These images contain only part of the information present in the original radionuclide images, and have to be mentally integrated with other known information to obtain a diagnosis. The proposed synthetic Fourier images overcome these deficiencies as their pixel intensity is a function of additional Fourier parameters of pixel time activity curves and of pixel location and are not limited to the first harmonic. But most importantly, their computation is based on "teaching" the computer by examples of previously diagnosed cases. The images offer direct and robust diagnosis which is superior to that derived from separate phase and amplitude images, especially for the detection of mild RWMA.

Fourier Analysis↗