PubMed Health⌕ Search

Biomedical subjects

E Onorato

Publications and source records attributed to E Onorato.

At least 19 recordsLinked to original sources

Silent brain embolism during transcatheter closure of patent foramen ovale: a transcranial Doppler study.

The aim of this report is to quantify the amount of spontaneous microembolism detected in brain vessels by transcranial Doppler (TCD) during transcatheter closure of right-to-left shunt (RLS). We examined 29 patients who had had a stroke or a transient ischaemic attack (17 females and 12 males; mean age 45+/-15 years). They all underwent TCD monitoring during the procedure and microembolic signals (MES) were recorded. Detection of MES was distributed as follows: during femoral catheterisation in 8 patients (25%), during atrial catheterisation in 5 patients (17%), during transeptal crossing in 14 patients (48%), during left disc opening in 28 patients (96%) and during right disc opening in 7 patients (24%). The highest rates of MES were observed during left disc opening and less during transeptal crossing with an average count of 31 (range 3-135) and 3 (range 1-18) respectively. Brain embolism occurs throughout the procedure after femoral catheterisation for PFO closure. Our results indicate that the majority of MES reached the brain during the opening of the left disc in the left atrium: 28/29 patients exhibited MES with an average of 31 (3-135), thus supporting the notion that gas embolism accounted for the findings.

Adult↗

Does transcatheter closure of patent foramen ovale really "shut the door?" A prospective study with transcranial Doppler.

BACKGROUND AND PURPOSE: Transcatheter closure of patent foramen ovale (PFO) is increasingly being performed and monitored with transthoracic or transesophageal echocardiography, whereas contrast-enhanced transcranial Doppler (ce-TCD), which probably represents the most suitable tool to quantify right-to-left shunt (RLS) in the brain vessels, has been systematically overlooked. Our goal is to prospectively assess efficacy and safety of PFO transcatheter closure using ce-TCD. METHODS: A total of 140 consecutive patients (mean age, 46+/-13 years; male/female ratio, 63/77) with PFO-related large RLS and no other recognized cause of focal cerebral ischemia underwent transcatheter closure. TCD was done preoperatively and 1 month after the procedure in all patients, after 3 months in 120, after 6 months in 112, and after 1 year in 104 patients. RESULTS: Implantation was successful in all patients. During Valsalva strain, a large shunt was still detectable in 31 of 140 (22%), 15 of 120 (13%), 9 of 112 (8%), and 9 of 104 (9%) patients at the 1-, 3-, 6-, and 12-month visits, respectively. Periprocedural and postprocedural complications included atrial fibrillation in 8% and scintillating scotomata in 6% of patients. During the 1-year follow-up period, only 1 transient ischemic attack was recorded in a patient with paroxysmal atrial fibrillation and complete PFO closure. CONCLUSIONS: Transcatheter PFO closure in patients with cryptogenic stroke and large RLS may be less successful than reported previously. TCD appears the ideal tool to follow up the closure process and to identify early, during follow-up, those patients who will be left with a significant shunt. Atrial fibrillation is more common than believed previously and may underlie the occurrence of further cerebrovascular events despite complete PFO closure. Irritative visual phenomena may occur as a consequence of nickel toxicity.

Adult↗

Combined catheter-based pulmonary valvuloplasty and atrial septal defect closure in Noonan syndrome. A case report and literature review.

The first case of combined procedure of catheter-based balloon pulmonary valvuloplasty and atrial septal defect closure using Amplatzer Septal Occluder, in a patient with Noonan syndrome, is reported. The literature regarding prevalence, genetics, pattern of involvement, symptoms, diagnosis, and treatment of this syndrome is reviewed.

Angioplasty, Balloon↗

Transcatheter treatment of coronary artery disease and atrial septal defect with sequential implantation of coronary stent and Amplatzer septal occluder: preliminary results.

Coronary stent implantation had been established as a highly effective revascularization technique in patients with occlusive coronary artery disease. Transcatheter closure of atrial septal defects is becoming a definite alternative to surgery in properly selected patients. During a 19-month period, 6 patients (50% women; mean age, 58 +/- 17 years; range, 32-73 years) of a consecutive series of 176 prospective multicenter registry patients undergoing transcatheter atrial septal defect closure were treated with sequential percutaneous coronary revascularization and Amplatzer septal occluder implantation. Indication for revascularization was stable angina in four patients and unstable angina in two. Indication for defect closure was significant left-to-right shunt with right ventricular enlargement. Defect diameter ranged from 13 to 20 mm by transesophageal echocardiography, and the stretched diameter measured 13 to 25 mm. Procedural success of both interventions was achieved in all cases without in-hospital complications. A total of seven stents were successfully implanted in five coronary vessels. No stent was used in one patient after successful PTCA. Immediate total closure of the defect was obtained in five patients. Trivial residual shunting, observed in one patient, disappeared at 24 hr. No adverse cardiac events, recurrence of anginal symptoms, or evidence of residual shunt were observed at clinical and echocardiographic follow-up, which ranged from 60 to 390 days (mean, 258 +/- 150 days). These results suggest that sequential transcatheter therapy of coronary artery disease and atrial septal defect is safe and efficacious in selected patients.

Adult↗

Use of Amplatzer septal occluder in a case of residual atrial septal defect causing bidirectional shunting after percutaneous Inoue mitral balloon valvuloplasty.

We describe a 70-year-old woman who underwent successful percutaneous Inoue antegrade-technique mitral valvuloplasty. Three months later, the patient developed right-sided heart failure. Color Doppler echocardiography and cardiac catheterization demonstrated an atrial septal defect with bidirectional shunting and no restenosis of the mitral valve (iatrogenic Lutembacher's syndrome). Percutaneous treatment was successfully accomplished using a 13 mm Amplatzer Septal Occluder (AGA Medical Corporation, Golden Valley, Minnesota). The causes of right-to-left shunting and the effects of body position on gas exchange in such patients are also discussed.

Aged↗

Patent ductus arteriosus closure using the new Amplatzer Duct Occluder. Preliminary results and review of the literature.

BACKGROUND: Patent ductus arteriosus (PDA) is the second most common congenital heart disease. A large number of surgical and transcatheter techniques for the interruption or closure of PDA has been reported. The aim of this study was to assess the immediate and short-term results of transcatheter closure of PDA using the new, self-expandable, self-centering, and repositionable Amplatzer Duct Occluder device. METHODS: We attempted occlusion of PDA with the Amplatzer Duct Occluder in seven consecutive patients, one child and six adults, four females and three males, between September 1999 and January 30th 2000. All PDAs but one were approached from the femoral venous site; the Amplatzer Duct Occluder size was selected in order to be 2 mm larger than the duct's diameter at its narrowest site and the mean PDA diameter was 5.4+/-2.5 mm (range 3-9). All patients underwent physical examination, chest X-ray and echocardiography within 48 hours and on first and third month after PDA occlusion. RESULTS: Four patients had a megaphone type (type A), and three had an elongated, conical type (type E) PDA. Four patients had immediate, complete angiographic closure of the ductus 10 minutes after the procedure, one had a trace shunt and two had small shunts which all disappeared within 48 hours. The average fluoroscopy time and procedural time were 34.4+/-10.6 min (range 21-50) and 105+/-38.9 min (range 75-190) respectively. There were no complications at follow-up. CONCLUSIONS: Transcatheter closure of PDA using the new Amplatzer Duct Occluder is an easy and effective technique. Moreover it is safe even in the presence of wide PDAs.

Adolescent↗

Results of transvenous buttoned device occlusion of patent ductus arteriosus in adults. International Buttoned Device Trial Group.

Examination of the immediate and follow-up results of transvenous buttoned device occlusion of patent ductus arteriosus suggests that the method is feasible, safe, and effective irrespective of the size and shape of the ductus. Although residual shunts are present, they tend to disappear during follow-up, and complete occlusion at the time of implantation may be achieved by incorporation of a folding plug over the button loop of the device.

Adolescent↗

International experience with secundum atrial septal defect occlusion by the buttoned device.

Several devices are available for transcatheter occlusion of atrial septal defect. This report describes the international experience with the buttoned device. During a 4.5-year period ending in February 1993, 180 transcatheter atrial septal defect occlusions were performed with the buttoned device. Patient age varied between 0.6 and 76 years and stretched atrial defect diameter between 5 and 25 mm. The defects were closed with 25 to 50 mm devices delivered through 8F (148 patients) or 9F (32 patients) sheaths. Twelve patients were adults whose defects were closed to prevent recurrence of cerebrovascular accidents caused by presumed paradoxic embolism. In the remaining patients the atrial defect was closed to treat the left-to-right shunt. The atrial septal defects were effectively occluded as demonstrated by (1) decrease in pulmonary-to-systemic flow ratio from 2.1 +/- 0.6 (mean +/- SD) to 1.05 +/- 0.1 (p < 0.01) by oximetry; (2) normalized S2 and disappearance of the diastolic murmur by auscultation; and (3) improvement in right ventricular volume overloading by echocardiogram. However, trivial to small shunts could be detected by color Doppler studies in 76 (45%) of 168 patients in whom such data are available. Complications included unbuttoning in 13 and whole-device embolization in 1. All patients remained stable, and retrieval of the device and surgical closure of the atrial septal defect were accomplished in 10 patients. Transcatheter retrieval was used in the remaining 4 patients. The incidence of unbuttoning, a major complication of the procedure, appeared to decrease with the increasing experience of the investigators and with device modification (third-generation). The follow-up duration varied between 1 month and 4 years. Six patients required surgery during the follow-up period. In the remaining patients (n = 160), clinical examination did not reveal signs of atrial shunts. Color Doppler studies revealed either complete disappearance of the previously demonstrated shunts or further diminution of their size. The results indicate that transcatheter occlusion of the atrial septal defects with buttoned devices is feasible, relatively safe, and effective, and it appears to be a viable alternative to surgery for some patients with secundum atrial septal defect. Complications are infrequent and should improve with experience.

Cardiac Catheterization↗

[Percutaneous closure of interatrial defect using the buttoned double-disk prosthesis].

BACKGROUND: Surgical repair is the procedure of choice for atrial septal defect correction. Even though surgical mortality is low (< 1%), morbidity is significant (anesthesia, thoracotomy, cardiopulmonary bypass, longer hospitalization and intensive care unit monitoring). Transcatheter methods to occlude atrial septal defects have been in development during the last two decades. We report our experience in Italy with the Sideris buttoned double-disk device. METHODS: From March 1992 to April 1993, 14 patients aged 20 months to 52 years, weight 10 to 82 kg, underwent transcatheter atrial septal defect occlusion with the Sideris buttoned device. The buttoned device is a miniaturized two disk device introduced through small venous sheaths (8-9 F). The diameter of atrial septal defects by echocardiography varied between 9 and 23 mm, while the balloon stretched diameter of the defects varied between 13 and 24 mm. The devices selected were 19 +/- 4 mm larger than the stretched diameter of the defect, but less than the total length of the septum (33-56 mm) by echo. RESULTS: Pulmonary-to-systemic flow ratio varied between 1.5 to 4.0. Mean pulmonary artery pressure varied between 10 and 24 mmHg (mean value 17 +/- 3.5 mm Hg). The relationship between different atrial septal defect measurements (echo, shunt flow, stretched diameter) was statistically analysed: transthoracic echo diameter had a good correlation with the balloon stretched diameter (r = 0.63, p < 0.001). The atrial septal defect was occluded in 12 patients (86% success rate). There was one early "unbuttoning" which was surgically corrected with success. The other patient underwent surgical correction 3 months later because of unsuitability for transcatheter closure. Minimal residual shunt detected by color flow mapping at 1 month follow-up was seen in 4 patients (33%). No complications occurred in any of our patients. CONCLUSIONS: This initial experience with the Sideris buttoned double-disk device demonstrated that transcatheter closure of atrial septal defect is feasible and effective. It can be accomplished through small introducing sheaths. Further clinical trials are justified. This method could become the procedure of choice for the correction of small ASDs.

Adolescent↗

Transfemoral closure of patent ductus arteriosus in adult patients.

Patent ductus arteriosus is an uncommon anomaly in adult patients. Surgical closure of patent ductus arteriosus in this age group presents difficult problems to the surgeon. We report our experience of 21 adult patients (19-62 years of age, mean 40 years) who underwent closure of the ductus by transfemoral implantation of a Rashkind double umbrella device. The patients came to light because of atrial fibrillation, congestive heart failure, residual flow after surgical ligation of the duct or because of incidental diagnosis made during physical examination or chest X-ray. In ten patients the pulmonary arterial pressure was normal (systolic pressure < 30 mmHg), in eleven it was elevated (systolic pressure from 30 to 100 mmHg, mean 50 mmHg). In seven patients the duct was clearly calcified and the size of the duct varied from 3 to 9 mm (mean 4.3 mm). In 16 patients the ductus resulted perfectly closed after implantation of the first double umbrella device, two patients had minimal residual aortopulmonary flow, whereas in three patients the residual shunt was significant; two of these also developed haemolysis and went to surgery, in the latter the shunt was completely abolished after implantation of a second 17-mm device 16 months later. In conclusion transcatheter closure of patent ductus arteriosus in adults is feasible, even in the presence of calcifications and/or pulmonary hypertension; taking into account the significant surgical risk, PDA umbrella closure should be considered the first choice procedure in this group of patients.

Adult↗

Iopamidol in cardioangiography: a retrospective, multicentre study. Part II. Paediatric patients.

To evaluate the complication rate in paediatric cardioangiography with the nonionic contrast medium iopamidol data on 8,166 procedures were retrospectively collected in 12 centres. The overall complication rate was 3.78% (309/8,166). 3.44% were related to the procedure, and 0.34% to the contrast medium. The mortality rate varied with age. It was higher in patients less than 2 months (0.38%) than in patients greater than 2 months-2 years (0.06%) and in patients older than 2 years (0.03%). The total complication rate was higher than the one observed in a similar retrospective analysis performed in adult patients (1.89%). This difference is probably due to higher risk conditions of the younger patients. However the contrast medium related complication rate (0.34% vs 0.4%) and the mortality rate (0.11% vs 0.1%) were comparable, confirming the good tolerability of iopamidol in cardiac catheterisation also in paediatric patients.

Age Factors↗

[Morphological and functional parameters of the left ventricle (mass, wall thickness and end-systolic stress) in school children with different levels of blood pressure, at rest and during maximal exercise].

Echocardiographically determined left ventricular mass, diastolic septal and posterior wall thickness and end-systolic wall stress, as well as electrocardiographic indexes of left ventricular enlargement (Sokolow-Lyon index and Romhilt-Estes score) and of left atrial enlargement (P terminal index) were correlated with resting and exercise systolic and diastolic blood pressures, and with several parameters of body size (weight, height, body surface area, Quetelet index), in 130 school children (61 boys, 69 girls) 6 to 15 years of age. Parameters of body size had a positive correlation both with systolic and diastolic blood pressures and with parameters of left ventricular size. Thus, the latter were adjusted for body surface area, for correlation with blood pressure. Left ventricular mass and diastolic septal and posterior wall thickness had a very poor correlation with resting and exercise diastolic blood pressures. Left ventricular mass and diastolic posterior wall thickness had a significantly higher correlation with peak exercise systolic blood pressure than with resting systolic blood pressure. End-systolic wall stress had a positive correlation with resting diastolic and systolic blood pressures. Electrocardiographic parameters of left ventricular and left atrial enlargement had a very poor correlation with resting and exercise blood pressure. Our findings suggest that early in life left ventricular mass and wall thickness are more closely related to maximal systolic blood pressure during physical exercise than to blood pressure in basal conditions. The electrocardiogram is an insensitive method to detect early modifications of left ventricular size in relation to different levels of blood pressure. The echocardiogram is the method of choice for this purpose.

Adolescent↗