PubMed Health⌕ Search

Biomedical subjects

E P Grimsrud

Publications and source records attributed to E P Grimsrud.

5 recordsLinked to original sources

Electron attachment to PSCl3.

Electron attachment to PSCl3 was studied in 133-Pa pressure of helium gas at temperatures from 298-550 K. Measurements of rate constants and branching fractions were made in a flowing-afterglow Langmuir-probe (FALP) apparatus. These experiments yielded an electron attachment rate constant of 5.1 x 10(-8) cm3 s(-1) that was found not to change significantly in the 298-550 K temperature range. This rate constant represents an attachment efficiency of about 14%. Attachment in 133 Pa of He gas yielded only the dissociative ion products PSCl2- and Cl-. The FALP data suggest that there is an activation energy of about 17 meV for production of PSCl2-. Attachment to PSCl3 was also studied at high pressure (9-93 kPa) of N2 in an ion mobility mass spectrometer, at 298 K. In contrast to the low-pressure data, the parent anion product channel (PSCl3-) was observed (along with the dissociative channels), and increased in importance with N2 pressure. Gaussian-3 (G3) calculations were carried out for PSCl3 and PSCl2 neutrals and anions to aid in interpretation of the experimental results. The calculations indicate that the electron affinity EA(PSCl2) is slightly smaller than EA(Cl), which may account for the observed branching fractions for PSCl2- and Cl- in the low-pressure experiments. A natural population analysis was performed to obtain the charges associated with each atom in the molecules in order to estimate how the attached electron is distributed. Comparison is made between the present study of electron attachment to PSCl3 and our earlier work on attachment to POCl3, and G3 calculations are reported here for neutral and anionic POCl2 and POCl3. In contrast to PSCl2, the calculations imply that EA(POCl2) is slightly greater than EA(Cl). For both PSCl3 and POCl3, the calculations show that the dissociative electron attachment process is close to thermoneutral.

Journal Article↗

Observed trends for CF3-containing compounds in background air at Cape Meares, Oregon, Point Barrow, Alaska, and Palmer Station, Antarctica.

The concentrations of CF(3)-containing compounds in archived air samples collected at Cape Meares, Oregon, from 1978 to 1997, at Point Barrow, Alaska, from 1995 to 1998, and at Palmer Station, Antarctica, from 1991 to 1997, were determined by high resolution gas chromatography and high resolution mass spectrometry. The CF(3)-containing compounds measured by this method and discussed here are: the perfluorinated compound, C(3)F(8) (FC 218); four perhalogenated compounds, CF(3)Cl (CFC 13), CF(3)CF(2)Cl (CFC 115), CF(3)CFCl(2) (CFC 114a), and CF(3)Br (Halon 1301); and three hydrofluorocompounds, CF(3)H (HFC 23), CF(3)CH(3) (HFC 143a), and CF(3)CH(2)F (HFC 134a). For four of these compounds, very few measurements have been previously reported. The atmospheric concentrations of all of the CF(3)-containing compounds continuously increased in time over the sample collection periods. From these data, the annual rates of emission into the atmosphere have been estimated. The emission rates fall into one of three distinct categories. The annual emission rates of C(3)F(8), CF(3)H, CF(3)CH(3), and CF(3)CH(2)F have continuously increased over the last two decades. That of CF(3)CFCl(2) has decreased continuously. Emission rates for CF(3)Cl, CF(3)CF(2)Cl, and CF(3)Br reached maximum levels in the late 1980s, and have been decreasing in the 1990s. The emission rates of C(3)F(8), CF(3)CH(3) and CF(3)CH(2)F were nearly zero 20 years ago but have increased rapidly during the last decade.

Air Pollutants↗

Improvements in the detection and analysis of CF3-containing compounds in the background atmosphere by gas chromatography-high-resolution mass spectrometry.

An improved method for the gas chromatography/mass spectrometry analysis of CF3-containing compounds in air is described. This method replaces a GS-Q porous layer open tubular (PLOT) column previously used with a 30 m x 0.32 mm GS-GasPro PLOT column. For this exceedingly volatile set of compounds the GS-GasPro column provides improved peak shapes, better signal-to-noise responses and no coelution of compounds. These improvements have allowed eleven CF3-containing compounds to be detected in background air, including CF4 (FC 14), C2F6 (FC 116), CF3Cl (CFC 13), CF3H (HFC 23), CF3Br (Halon 1301), C3F8 (FC 218), CF3CF2Cl (CFC 115), CF3CHF2 (HFC 125), CF3CH3 (HFC 143a), CF3CH2F (HFC 134a), and CF3CFCl2 (CFC 114a). Three of these compounds have not been previously detected in background air, to our knowledge. Quantitative determinations for each of these compounds in the background atmosphere of Montana are also reported.

Air Pollutants↗

Enhancement of electron-capture detection of methyl bromide in air by iodination.

An instrumentally simple and cost-effective method for the direct analysis of methyl bromide in ambient air is described. The method is based on the separation of sample components by gas chromatography, the conversion of methyl bromide to methyl iodide by reaction with an inorganic iodide salt, and the detection of the methyl iodide thereby produced by an electron-capture detector. Of the 20 different inorganic salts investigated here for conversion of methyl bromide to methyl iodide, zinc iodide was found to provide the greatest conversion efficiency. In addition, zinc iodide was found to provide high conversion efficiency at a modest reaction temperature, thereby minimizing both the thermal decomposition of compounds within the reaction volume and the level of column bleed introduced to the detector. The reactions of several other brominated and chlorinated organic compounds with zinc iodide have also been characterized. The successful application of this instrument to the quantitative determination of methyl bromide in a local background air sample is then demonstrated.

Air↗