Comparison of closed-loop controlled administration of propofol using Bispectral Index as the controlled variable versus "standard practice" controlled administration.

BACKGROUND: This report describes a new closed-loop control system for propofol that uses the Bispectral Index (BIS) as the controlled variable in a patient-individualized, adaptive, model-based control system, and compares this system with manually controlled administration of propofol using hemodynamic and somatic changes to guide anesthesia. METHODS: Twenty female patients, American Society of Anesthesiologists physical status I or II, who were scheduled for gynecologic laparotomy were included to receive propofolremifentanil anesthesia. In group I, propofol was titrated using a BIS-guided, model-based, closed-loop system. The BIS target was set at 50. In group II, propofol was titrated using classical hemodynamic signs of (in)adequate anesthesia. Performance of control during induction and maintenance of anesthesia were compared between both groups using BIS as the controlled variable in group I and the reference variable in group II, and, conversely, the systolic blood pressure as the controlled variable in group II and the reference variable in group I. At the end of anesthesia, recovery profiles between groups were compared. RESULTS: Although patients undergoing manual induction of anesthesia in group II at 300 ml/h reached a BIS level of 50 faster than patients undergoing open-loop, computer-controlled induction in group I, manual induction caused a more pronounced initial overshoot of the BIS target. This resulted in a more pronounced decrease in blood pressure in group II. During the maintenance phase, better control of BIS and systolic blood pressure was found in group I compared with group II. Recovery was faster in group I. CONCLUSION: A closed-loop system for propofol administration using the BIS as a controlled variable together with a model-based controller is clinically acceptable during general anesthesia.

Adolescent↗

Only carbon dioxide absorbents free of both NaOH and KOH do not generate compound A during in vitro closed-system sevoflurane: evaluation of five absorbents.

BACKGROUND: Insufficient data exist on the production of compound A during closed-system sevoflurane administration with newer carbon dioxide absorbents. METHODS: A modified PhysioFlex apparatus (Dräger, Lübeck, Germany) was connected to an artificial test lung (inflow at the top of the bellow approximately/= 160 ml/min CO2; outflow at the Y piece of the lung model approximately/= 200 ml/min, simulating oxygen consumption). Ventilation was set to obtain an end-tidal carbon dioxide partial pressure of approximately 40 mmHg. Various fresh carbon dioxide absorbents were used: Sodasorb (n = 6), Sofnolime (n = 6), and potassium hydroxide (KOH)-free Sodasorb (n = 7), Amsorb (n = 7), and lithium hydroxide (n = 7). After baseline analysis, liquid sevoflurane was injected into the circuit by syringe pump to obtain 2.1% end-tidal concentration for 240 min. At baseline and at regular intervals thereafter, end-tidal carbon dioxide partial pressure, end-tidal sevoflurane concentration, and canister inflow (T degrees(in)) and canister outflow (T degrees(out)) temperatures were measured. To measure compound Ainsp concentration in the inspired gas of the breathing circuit, 2-ml gas samples were taken and analyzed by capillary gas chromatography plus mass spectrometry. RESULTS: The median (minimum-maximum) highest compound Ainsp concentrations over the entire period were, in decreasing order: 38.3 (28.4-44.2)* (Sofnolime), 30.1 (23.9-43.7) (KOH-free Sodasorb), 23.3 (20.0-29.2) (Sodasorb), 1.6 (1.3-2.1)* (lithium hydroxide), and 1.3 (1.1-1.8)* (Amsorb) parts per million (*P < 0.01 vs. Sodasorb). After reaching their peak concentration, a decrease for Sofnolime, KOH-free Sodasorb, and Sodasorb until 240 min was found. The median (minimum-maximum) highest values for T degrees(out) were 39 (38-40), 40 (39-42), 41 (40-42), 46 (44-48)*, and 39 (38-41) degrees C (*P < 0.01 vs. Sodasorb), respectively. CONCLUSIONS: With KOH-free (but sodium hydroxide [NaOH]-containing) soda limes even higher compound A concentrations are recorded than with standard Sodasorb. Only by eliminating KOH as well as NaOH from the absorbent (Amsorb and lithium hydroxide) is no compound A produced.

Absorption↗

Comparison of plasma compartment versus two methods for effect compartment--controlled target-controlled infusion for propofol.

BACKGROUND: Target-controlled infusion (TCI) systems can control the concentration in the plasma or at the site of drug effect. A TCI system that targets the effect site should be able to accurately predict the time course of drug effect. The authors tested this by comparing the performance of three control algorithms: plasmacontrol TCI versus two algorithms for effect-site control TCI. METHODS: One-hundred twenty healthy women patients received propofol via TCI for 12-min at a target concentration of 5.4 microg/ml. In all three groups, the plasma concentrations were computed using pharmacokinetics previously reported. In group I, the TCI device controlled the plasma concentration. In groups II and III, the TCI device controlled the effect-site concentration. In group II, the effect site was computed using a half-life for plasma effect-site equilibration (t1/2k(eo)) of 3.5 min. In group III, plasma effect-site equilibration rate constant (k(eo)) was computed to yield a time to peak effect of 1.6 min after bolus injection, yielding a t1/2keo of 34 s. the time course of propofol was measured using the bispectral index. Blood pressure, ventilation, and time of loss of consciousness were measured. RESULTS: The time course of propofol drug effect, as measured by the bispectral index, was best predicted in group III. Targeting the effect-site concentration shortened the time to loss of consciousness compared with the targeting plasma concentration without causing hypotension. The incidence of apnea was less in group III than in group II. CONCLUSION: Effect compartment-controlled TCI can be safely applied in clinical practice. A biophase model combining the Marsh kinetics and a time to peak effect of 1.6 min accurately predicted the time course of propofol drug effect.

Adolescent↗

In vitro compound A formation in a computer-controlled closed-circuit anesthetic apparatus. Comparison with a classical valve circuit.

BACKGROUND: Few data exist on compound A during sevoflurane anesthesia when using closed-circuit conditions and sodalime with modern computer-controlled liquid injection. METHODS: A PhysioFlex apparatus (Dräger, Lübeck, Germany) was connected to an artificial test lung (inflow approximately 160 ml/min carbon dioxide, outflow approximately 200 ml/min, simulating oxygen consumption). Ventilation was set to obtain an end-tidal carbon dioxide partial pressure (Petco2) approximately 40 mmHg. Canister inflow (T degrees in) and outflow (T degrees out) temperatures were measured. Fresh sodalime and charcoal were used. After baseline analysis, sevoflurane concentration was set at 2.1% end-tidal for 120 min. At baseline and at regular intervals thereafter, Petco2, end-tidal sevoflurane, T degrees in, and T degrees out were measured. For inspiratory and expiratory compound A determination, samples of 2-ml gas were taken. These data were compared with those of a classical valve-containing closed-circuit machine. Ten runs were performed in each set-up. RESULTS: Inspired compound A concentrations increased from undetectable to peak at 6.0 (SD 1.3) and 14.3 (SD 2.5) ppm (P < 0.05), and maximal temperature in the upper outflow part of the absorbent canister was 24.3 degrees C (SD 3.6) and 39.8 degrees C (SD 1.2) (P < 0.05) in the PhysioFlex and valve circuit machines, respectively. Differences between the two machines in compound A concentrations and absorbent canister temperature at the inflow and outflow regions were significantly different (P < 0.05) at all times after 5 min. CONCLUSION: Compound A concentrations in the high-flow (70 l/min), closed-circuit PhysioFlex machine were significantly lower than in conventional, valve-based machines during closed-circuit conditions. Lower absorbent temperatures, resulting from the high flow, appear to account for the lower compound A formation.

Anesthesia, Closed-Circuit↗

Cardiopulmonary bypass and the pharmacokinetics of drugs. An update.

Cardiopulmonary bypass is accompanied by profound changes in the organism that may alter the pharmacokinetics of drugs. Drug distribution can be altered, for example, by changes in blood flow and by haemodilution, with a decrease in protein binding; a decrease in the elimination of some drugs can be caused by impairment of renal or hepatic clearance, due, for example, to lowered perfusion and hypothermia. The subject was reviewed in the Journal in 1982, and the emphasis of the present review is on new data related to specific drugs. The following substances are dealt with: benzodiazepines, cephalosporins, digitalis glycosides, general anaesthetics, glyceryl trinitrate (nitroglycerin), lignocaine (lidocaine), muscle relaxants, nitroprusside, opiates, papaverine and propranolol. For many of these substances an abrupt decrease has been observed in serum concentration upon initiation of bypass, which is explained by haemodilution and an increase in distribution due to decreased protein binding. For nitrates and some opiates, adsorption to the bypass apparatus was shown to be important. The gradual increase in serum concentrations seen during cardiopulmonary bypass with some drugs after the initial fall is usually explained by redistribution of the drug and/or decrease in its elimination. The same phenomena are thought to explain why in the post-bypass period a concentration increase occurs, or at least a slower decrease than expected. However, drug elimination has been directly measured in only a few studies. The short duration of the bypass procedure and the continuous changes during the process hamper a rigorous pharmacokinetic evaluation. Studies allowing more precise understanding of the mechanisms underlying the observed concentration changes are needed, but are difficult to design. Similarly, more data are awaited on the pharmacodynamic and clinical consequences of the concentration changes.

Anesthetics↗

A paravenous approach for the saphenous nerve block.

BACKGROUND AND OBJECTIVES: This study assesses a paravenous approach for saphenous nerve block at approximately the level of the tibial tuberosity, and compares it with the conventional technique of blind subcutaneous infiltration between the tibial tuberosity and the gastrocnemius muscle. METHODS: In dissections of 5 cadavers, the saphenous nerve was found very close to the saphenous vein bilaterally. Subsequently, in 20 volunteers, a bilateral saphenous nerve block was performed with 5 mL mepivacaine on each side. Randomly assigned, the block was performed by blind subcutaneous injection using a 23-gauge needle of 2.5 cm on one side and by a paravenous subcutaneous approach on the other. RESULTS: The paravenous approach produced a saphenous nerve block in all 20 volunteers whereas the blind subcutaneous approach was successful in only 6 (33%) (P <.05). Seven volunteers had a painless minor hematoma at the paravenous site and 2 had a hematoma at the classical site. CONCLUSION: The saphenous nerve can be blocked effectively by a paravenous approach using only 5 mL of local anesthetic solution. This approach is advantageous because of its easily identifiable landmark.

Adult↗