A new versatile PC-based lung sound analyzer with automatic crackle analysis (HeLSA); repeatability of spectral parameters and sound amplitude in healthy subjects.

A versatile PC-based lung sound analyzer has been developed for short-term recording and analysis of respiratory sounds in research and clinical applications. The system consists of two sound sensors, a flow sensor, a filtering signal amplifier and a PC with a data acquisition card and software for measurement and analysis of the sounds. The analyses include phonopneumography, time expanded waveform analysis, spectral analysis with time averaged Fast Fourier Transform, frequency analysis in time domain (sonogram), and automatic detection and waveform analysis of crackles. Short-term repeatability of spectral parameters of tracheal and lung sounds was studied in 10 healthy subjects. The coefficients of variation (CoV) of the averaged quartile frequencies (F25, F50 and F75) of lung sounds during flow-controlled tidal breathing were 3.7, 4.0 and 8.9% in expiration and 2.7, 3.5 and 4.5% in inspiration, respectively. CoVs of the averaged F25, F50 and F75 of expiratory tracheal sounds were 6.9, 3.0 and 2.4%, and those of inspiratory tracheal sounds 6.3, 2.6 and 3.3%, respectively. Examples of lung sound analysis of samples containing adventitious sounds such as crackles and wheezes are presented. The results indicate that the median frequency has the best repeatability of quartile frequencies of breath sounds and they suggest that the variations of those parameters are low enough for diagnostic purposes. The results also suggest that the analyzer can be a useful new tool for pulmonary research in the fields of physiological and clinical short-term studies of respiratory sounds.

Adult↗

Averaged and time-gated spectral analysis of respiratory sounds. Repeatability of spectral parameters in healthy men and in patients with fibrosing alveolitis.

STUDY OBJECTIVE: To obtain a basis for assessment of changes in breath sound spectra in patients with pulmonary diseases, short-term and day-to-day repeatability of spectral parameters was studied. DESIGN: Breath sounds were recorded simultaneously from the trachea and from the chest twice at an interval of 15 min (short-term repeatability) and of 1 to 3 days (day-to-day repeatability). During recordings, air flow at the mouth was controlled, the target inspiratory and expiratory peak flow being 1.25 L/s. Inspiratory and expiratory breath sound spectra were averaged over 7 to 10 successive respiratory cycles. The repeatability of sound intensity (RMS), frequency of maximum intensity (Fmax), and median frequency (F50) was analyzed with analysis of variance. PARTICIPANTS: Short-term repeatability was studied in 10 healthy nonsmoking men (age 25 to 44 years), and day-to-day repeatability was studied in 10 healthy nonsmoking men (age 23 to 41 years) and in 12 patients with clinically stable fibrosing alveolitis (age 35 to 82 years). RESULTS: Short-term coefficient of variation (CoV) of Fmax and F50 was 2.6 to 6.7% when recorded from the chest, and 6.2 to 8.7% when recorded from the trachea. Day-to-day CoV of Fmax and F50 in healthy subjects was 4.7 to 8.5% and 5.0 to 8.7% recorded from the chest or from the trachea, respectively. Inspiratory day-to-day variation in those parameters was higher in patients with fibrosing alveolitis. CoV of RMS was high, ranging from 18 to 47% in different subject groups and sampling situations. CONCLUSIONS: Repeatability of F50 of averaged flow-controlled lung sound spectra is good both in healthy subjects and in patients with fibrosing alveolitis. Thus, F50 of respiratory sound spectra may be useful in monitoring of changes induced by respiratory diseases and interventions. These results emphasize the importance of standardization of recording conditions and of analyzing techniques.

Adult↗

Changes in frequency spectra of breath sounds during histamine challenge test in adult asthmatics and healthy control subjects.

Air-flow standardized breath sounds were recorded at the chest and at the trachea during histamine challenge test and after subsequent bronchodilation in 12 asthmatics and 6 healthy controls for spectral analysis, to be compared with simultaneous changes in spirometric variables. Of all the lung sound variables measured, the changes in median frequency of the power spectrum (F50) of tracheal expiratory sounds were found to correlate best (r = 0.853, p < 0.0001) with changes in FEV1. The increase of F50 during histamine challenge was significantly larger in asthmatics than in healthy control subjects (p < 0.005). The provocative dose of histamine inducing a decrease of 15 percent in FEV1 (PD15FEV1) and the provocative dose causing an increase of 30 percent in tracheal expiratory F50 (PD30F50) were significantly related (r = 0.754, p = 0.012). In asthmatics, the breath sound frequency distribution in terms of median frequency reflected acute changes in airways obstruction with high sensitivity and specificity. The present method for breath sound analysis can be applied for patients with limited cooperation during bronchial challenge tests.

Adolescent↗

Original waveform of lung sound crackles: a case study of the effect of high-pass filtration.

In lung sound research, low-frequency noise usually disturbs the sound signal being recorded. Some researchers therefore use high-pass filtration before the final analysis. In this study, the effect of digital and analog high-pass filtration on the morphology of the lung sound crackles is evaluated. The original nonprefiltered crackle waveform is presented, and the effect of the high-pass filtration on the crackle waveform characteristics is elucidated in one patient with silicoasbestosis.

Acoustics↗