Publications and source records attributed to E Palayiwa.

9 recordsLinked to original sources

An evaluation of the Brüel and Kjaer monitor 1304.

A laboratory evaluation was performed on the Brüel and Kjaer multigas monitor 1304, incorporating a pulse oximeter. The instrument was tested for accuracy, stability, response and delay times, frequency response and the effects of water vapour, alcohol, cyclopropane and sevoflurane. The instrument's performance was found to be within or very close to the manufacturer's specifications for accuracy, stability and response and delay times. It was unaffected by water vapour and alcohol and the effect of cyclopropane on the vapour channel was lower than has been reported for other analysers. The response to sevoflurane was of the same order as that of the other vapours. A 90% response to square wave changes of gas composition was maintained up to 60 breaths.min-1 for CO2, O2, and N2O and up to 40 breaths.min-1 for the vapours when the nafion sampling tube was used.

Anesthesia, Inhalation

A new microprocessor-controlled anaesthetic machine.

This paper describes the development of a microprocessor controlled anaesthetic machine comprising an integrated anaesthetic apparatus and monitoring system. Following prolonged reliability trials in the laboratory, changes have been made to major components which were described in earlier publications.

Anesthesiology

An automated interferometer for the analysis of anaesthetic gas mixtures.

A microprocessor-controlled interferometer is described. The eyepiece of a conventional Jamin type interferometer has been replaced by an array of photocells which records the intensity across the interference pattern. Mathematical correlation procedures are used to locate the principal interference pattern maximum and, by sequential analysis of a fresh gas mixture followed by fresh gas plus vapour, it is possible to determine both oxygen and vapour concentrations. The instrument was used to analyse mixtures of oxygen and nitrous oxide and also oxygen, nitrous oxide plus halothane. It was found that the oxygen concentration could be determined to an accuracy of +/- 1% v/v and the vapour concentration to +/- 0.1% v/v. The instrument is suitable for monitoring concentrations delivered by an anaesthetic machine and may be included in a microprocessor-controlled anaesthetic machine.

Analog-Digital Conversion

Evaluation of a multigas anaesthetic monitor: the Datex Capnomac.

A laboratory investigation was carried out to evaluate the performance of the Datex Capnomac multigas anaesthetic agent analyser, with particular emphasis on accuracy, response and delay times, zero and gain stability and interference from water vapour. The analysis of anaesthetic vapours was less accurate than the analysis of CO2, O2 and N2O, but acceptable for clinical use. The response to square wave changes in gas composition was accurate at frequencies up to 60 per minute for CO2 and 30 per minute for O2, but with N2O and the anaesthetic vapours there was a decrease in accuracy at frequencies above 20 breaths/minute. The instrument appeared to be unaffected by water vapour.

Anesthetics

A microprocessor-controlled anaesthetic vaporizer.

A microprocessor-controlled anaesthetic vaporizer is described. Fresh gas is mixed in the correct proportions using two pulsed solenoid valves and a proportion of this passes through a third pulsed solenoid valve and is bubbled through liquid halothane. The temperature of the liquid agent is measured and the pulse frequency is modified to give the correct vapour concentration for the set flow rate and measured temperature. Initially, the vapour was produced by bubbling fresh gas through the agent in a conventional halothane bottle. However, because of the large liquid volume available, nitrous oxide was found to dissolve in large quantities in the halothane. A small volume vaporizer which was continually replenished from a reservoir was designed. Measurements of the vapour concentrations emerging from such a vaporizer were made and were found to agree with the set values +/- 0.1% v/v.

Anesthesia, Inhalation

A microprocessor-controlled gas mixing device.

This paper describes the use of solenoid valves for the production of binary gas mixtures. The system is controlled by a microprocessor and is capable of delivering accurate flows and concentrations of gases over the ranges commonly used in anaesthesia. Since the flow produced by the valves is pulsatile, a system for mixing the gases and smoothing the pulses is described. A back pressure regulator is fitted downstream of each of two mixing/damping chambers and a method of using this as a flow transducer is described. The advantages of this system over conventional rotameters are discussed.

Anesthesia, Inhalation

Nitrous oxide solubility in halothane and its effect on the output of vaporizers.

The absorption of nitrous oxide in halothane was studied by bubbling nitrous oxide and nitrous oxide/oxygen gas mixtures through a halothane bottle, using 100% oxygen as a control. The gas volume emerging from the halothane bottle was measured each minute, over a period of up to 15 minutes. When oxygen was used as a control gas, the averaged flow rate dropped slightly over the experimental period, due to the cooling of the halothane. However, in the presence of nitrous oxide, the initial flow rate of the gas emerging from the halothane bottle was greatly diminished, but then accelerated rapidly to reach that obtained with oxygen. The results suggested that nitrous oxide dissolved in large quantities in halothane, and the data are consistent with an Ostwald coefficient in excess of 4.0.

Absorption