PubMed Health⌕ Search

Biomedical subjects

E Ponce de León

Publications and source records attributed to E Ponce de León.

4 recordsLinked to original sources

[Validation of the three-dimensional method of sestamibi gated-SPECT in the calculation of the left ventricular ejection fraction in patients with ischemic heart disease. Comparison with contrast ventriculography].

INTRODUCTION AND OBJECTIVE: Tomography with acquisition synchronized with electrocardiography, gated-tomography, allows the assessment of left ventricular contractile function. The accuracy of a new method of gated-tomography, based on the three dimensional representation of the left ventricle to calculate the ejection fraction was validated by means of comparison with contrast ventriculography. METHODS: We studied 85 patients with ischemic cardiopathy, and ejection fraction was calculated by contrast ventriculography and sestamibi-gated-tomography, at rest and throughout 10 micrograms/kg/min of dobutamine. Furthermore, we assessed the extent of perfusion defect, as well as the number of segments with activity below 50% of the total 13 segments in which the tomographic slices were divided. RESULTS: Gated-tomography was significantly correlated to contrast ventriculography in the calculation of ejection fraction, both with acquisition at rest (r = 0.80) and throughout Dobutamine (r = 0.82). The average underestimation of gated-tomography calculation of ejection fraction was significantly greater for the rest study (-0.12 [IC 95% 0.04, -0.30]) than the dobutamine study (-0.07 [IC 95% 0.09, -0.24]). Patients with greater perfusion defects (4 o more segments) had no differences in underestimation of ejection fraction (-0.13 [IC 95% 0.03, -0.30] versus -0.11 [IC 95% 0.07, -0.29]). CONCLUSIONS: The three-dimensional method of gated-tomography accurately assesses the ejection fraction. The underestimation determined by this method was lower in the study done with viable doses of dobutamine. The extent of perfusion defect had no deleterious effect on gated-tomography in the calculation of ejection fraction.

Adult↗

Small, flat colorectal neoplasias in long-standing ulcerative colitis detected by high-resolution electronic video endoscopy.

BACKGROUND: High-resolution video endoscopy complemented with chromoscopy allows for more detailed visualization of the colonic mucosal surface. METHODS: Using high-resolution video endoscopy and chromoscopy, we investigated 85 patients with extensive ulcerative colitis with a disease duration of at least 10 years who were taking part in a cancer surveillance program. RESULTS: In 38 of the 85 patients, 104 polyps were detected at endoscopy. Seventy-seven (74%) of the 104 polyps were endoscopically flat, 21 (20%) were sessile, 3 (3%) were pedunculated, and 3 (3%) had no recorded morphology. Twenty-three (22%) polyps were neoplastic (15 flat, 5 sessile, 2 pedunculated, 1 not recorded). Low-grade dysplasia was found in 21 of the 23 neoplastic polyps and high-grade dysplasia in the remaining 2 (1 flat tubular adenoma and 1 sessile villous adenoma with invasive growth). Flat polyps were small, with a diameter of 5 mm or less in 73% (n = 56) of cases. At histology flat polyps revealed either flat adenomas (n = 11; 14.3%), tubular or villous structures with dysplastic cells at the lower part of the crypts (n = 4; 5.2%), flat hyperplastic polyps (n = 26; 34%), inflammatory mucosa (n = 5; 6.5%), or mucosa in remission (n = 31; 40%). CONCLUSION: The use of high-resolution video endoscopy complemented with chromoscopy in ulcerative colitis enables the detection of flat neoplastic polyps. The existence of those hitherto undetected neoplasms in ulcerative colitis and their possible role in the histogenesis of colorectal cancer in ulcerative colitis deserve further investigation.

Adenoma↗

[Immunizations].

Explore the source record for details and available documents.

BCG Vaccine↗