PubMed Health⌕ Search

Biomedical subjects

E R Savolaine

Publications and source records attributed to E R Savolaine.

At least 19 recordsLinked to original sources

Assessment of femoral neck nonunion with multiplanar computed tomography reconstruction.

Femoral neck fracture nonunion after implant fixation is usually evaluated by physical findings and serial radiography. Radiography in hip fixation is complicated by inherent anatomy and the geometry of screw placement. Computed tomography with multiplanar reconstruction offers adjunct evaluation using nonstandard imaging planes tailored to favor fracture plane projection and individual screw evaluation. Metal artifacts can be minimized and lack of fracture bridging can be excluded with confidence. Experience with seven cases of femoral neck fracture nonunion is presented along with image examples.

Aged↗

Basal skull fracture with traumatic polycranial neuropathy and occluded left carotid artery: significance of fractures along the course of the carotid artery.

A patient who survived with traumatic multiple cranial nerve palsies and occluded internal carotid artery associated with a basal skull fracture that involved the carotid canal is described. A literature review indicates that a wide variety of injuries can occur to the carotid artery as it passes through a fractured skull base. Basal fractures involving the course of the carotid artery reflect a significant risk of carotid injury.

Accidents, Traffic↗

Postoperative magnetic resonance imaging evaluation of Pipkin fractures fixated with titanium implants: a report of two cases.

Previous studies have documented the effectiveness of magnetic resonance imaging for evaluating and following up the development of avascular necrosis of the femoral head. One of the limitations of this technique, however, is the distortion that is encountered with ferromagnetic screws. A traumatic fracture to the femoral head is a risk factor for avascular necrosis. The addition of internal fixation, which is often required in Pipkin-type fractures of the femoral head, creates significant image distortion on magnetic resonance scans used for postoperative follow-up. The artifact and field distortion present in magnetic resonance imaging when ferromagnetic screw fixation is used has been avoided at our institution by the use of titanium hardware. The authors, therefore, recommend the use of titanium screws in the fixation of Pipkin-type fractures in the hip joint.

Adult↗

Coronal fracture of the body of the hamate.

Fractures of the body of the hamate are unusual. Eleven patients with coronal fractures of the hamate bone, all involving dislocation of the hamate-metacarpal joint, are reported. Routine roentgenograms were not helpful in delineating the presence of the injury in five patients; therefore, fracture diagnosis was not initially made in those patients. The average delay in diagnosis of this group was 10 days. A 30-degree pronated view, tomograms, and computed tomography scans may be necessary in the diagnosis of this injury. This fracture was found to be highly unstable. Ten patients underwent surgery for stabilization of their fractures and restoration of the congruity of the hamate-metacarpal joint. Four patients were treated with open reduction and internal fixation of the fracture. Six patients were treated with closed reduction and percutaneous pinning. All patients treated surgically had maintenance of reduction of their joints. One patient was treated with closed reduction and casting; reduction in this case was lost, and the patient developed residual subluxation of the hamate-metacarpal joint.

Adolescent↗

Posterior plating of the cervical spine.

A retrospective review of 36 patients treated with posterior cervical plating and autogenous iliac crest bone graft was performed to evaluate the results of posterior cervical plating in terms of fusion, outcome, technique, and complications. Numerous methods of cervical stabilization have been described with varying fusion rates and complications. Compared to wiring techniques, there is little information concerning the results of posterior cervical plating. Thirty-six patients with cervical instability underwent posterior plating with lateral mass screw fixation. Twenty-two had acute traumatic instability, four had late traumatic instability, six had metastatic disease, and four had postlaminectomy spondylotic instability. A Minerva brace was worn postoperatively for 3 months and fusion was assessed by bone incorporation on plain films, stable dynamic flexion-extension views, and absence of neck pain. Postoperative MRI and CT imaging was assessed in those patients who underwent these modalities. Fusion occurred at an average of 3 months in all patients. One patient demonstrated postoperative neurologic deterioration, but this resolved with subsequent decompression. Six patients had loosening of short, unicortical screws, but this did not affect the fusion result in five of these patients. The use of titanium implants allowed operative CT and MR imaging without the excessive artifact associated with stainless steel implants. Posterior cervical plating with lateral mass fixation and bone grafting offers a reliable method of achieving fusion. Bicortical lateral mass screws are less likely to loosen than unicortical screws, and no major complications occurred.

Adolescent↗

Multiplanar magnetic resonance imaging of the sacral foramina and presacral space.

The sacrum and presacral space present a complex and somewhat troublesome area for radiologic evaluation but are of considerable significance in disease processes of interest to oncology, neurosurgery, and orthopedic surgery. The multiplanar capabilities of magnetic resonance imaging (MRI) can be employed to define fracture pathology and neoplastic destruction alike. Some alternate MRI anatomic planes are presented and explored in normal volunteers and in 30 random clinical cases.

Adolescent↗

Longitudinal fracture of the sacrum: case report.

A 51-year-old woman was involved in a motor vehicle crash, sustaining multiple injuries including a longitudinal displaced burst fracture of the sacrum associated with neurologic deficits and fractures of the pelvis. A computed tomographic scan was valuable in properly identifying the extent of the sacral fracture. Because of the neurologic deficits and displacement of the sacral fracture, decompression of the sacral canal and attempted reduction of the sacral fracture and fixation of the pelvic fracture were performed. The patient's neurologic deficits improved, and at last follow-up examination she was ambulating without assistance.

Female↗

Use of titanium implants in pedicular screw fixation.

Several types of pedicular screw systems have been utilized to augment lumbar spine fusion. All systems are made of stainless steel, which interferes with imaging techniques, especially MRI and CT scans. In search of a solution for this problem, we decided to study the use of titanium systems in the lumbar spine. Because there were no titanium pedicle screw systems available on the market, we decided to use the titanium Alta system currently used for femur fractures. This report details our experience in using this device for lumbar spine fusion. From 1990 to 1992, 25 patients underwent thoracic and lumbar fusion with Alta titanium screws and plates. Spinal fusion was performed for a variety of conditions, including metastatic tumor, fracture, spondylolisthesis, pseudoarthrosis, and postdecompressive instability. All but two patients obtained solid fusion clinically and radiographically and considerable improvement in back pain. There was loosening of the implant in both patients. Both patients had osteoporosis. One of these two patients developed pseudoarthrosis, which required further surgery. The other patient with a metastatic tumor of the spine remained asymptomatic without change in the spine alignment despite progression of the tumor. There were no broken screws encountered during follow-up. Two patients sustained subsequent fracture of the vertebra above the fusion. One of the patients also developed a fracture below the fusion. Fusion with titanium implants allowed postoperative evaluation and subsequent periodic examination of the spinal canal with high-quality MR images as well as significant reduction of artifacts on CT scan.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Subluxation of the cervical spine caused by 3-point seat belt.

Cervical spine injuries associated with 3-point (lap-sash) seat belt restraint systems are uncommon and usually without serious sequelae. However, the potential for unstable subluxation or dislocation due to severe flexion-extension mechanism is present and may result in severe disability if not promptly recognized and treated. Such an unstable injury is reported here and was treated with internal fixation. Further attention should be given to the ability of headrests, air bags, and other restraints to protect the cervical spine.

Adult↗

Magnetic resonance imaging evaluation of the spine with metal implants. General safety and superior imaging with titanium.

We studied the cases of 15 patients who underwent postoperative magnetic resonance imaging evaluation after being treated with metal spinal implants. Spine stabilization was required in traumatic injuries for eight patients, cancer destruction in four patients, late cervical subluxation in one patient, spondylosis in one patient, and spondylolisthesis in one patient. A variety of stainless steel and titanium spinal implants were used. The images were evaluated for spinal and implant positioning and artifact production. Both stainless steel and titanium implants were imaged safely and there was no evidence of implant migration of local tissue-heating effect. The titanium spinal implants allowed postoperative spine imaging without the significant image distortion characteristic of the stainless steel implants. The stainless steel implants created significant artifact that impaired the usefulness of the magnetic resonance imaging evaluation.

Adult↗

Comminuted fracture of the calcaneus associated with subluxation of the talus.

Two cases of complex fracture dislocation of the calcaneus having an unusual pattern of injury are described. The cases exhibit the following special characteristics: (1) fracture dislocation of the calcaneus where the primary fracture line separates the calcaneus into an anteromedial fragment that maintains its normal relationship to the talus and a posterolateral fragment that is dislocated from the subtalar joint. This posterolateral fragment moves laterally and lies adjacent to the fibula; (2) a secondary fracture line separating the lateral portion of the posterior facet from the tuberosity of the calcaneus. Both fragments are dislocated from their normal anatomical position; (3) talar tilt as shown on AP view of the ankle caused by inversion of the talus due to rupture of the lateral collateral ligament. Also, the posterolateral fragments impinging on the fibula pushes the heel downward and contributes to the talar tilt; (4) involvement of the calcaneocuboid joint; (5) dislocation of the peroneal tendons. This fracture pattern is unusual and has not been described before. Recognition of this unusual injury with subsequent and proper management may prevent major disability to the patient. Conservative treatment by casting or early range of motion is contraindicated. Closed reduction should be attempted immediately, and if not successful, a lateral approach with open reduction and internal fixation is the treatment of choice for this complex injury.

Adult↗

Fibular nonunion in combination with fractures of the tibia.

Seventeen cases of fibular nonunion or delayed union were seen in our institution from 1985 to 1990. All but one of these cases were associated with nonunion of the tibia which was diagnosed radiologically and/or surgically. The fibula characteristically heals before the tibia; therefore, if the fibula is slow in healing or showing nonunion, more intensive investigation of the tibia for occult nonunion, or delayed union, should be done to determine whether early surgical intervention would be necessary to avoid prolonging the course of treatment. Nonunion of the fibula may indicate instability of the fractured tibia. The authors have examined the relationship of this mutual nonunion and recommend careful observation of the fibular healing in associated fractures of the tibia and fibula.

Adolescent↗

Soft-tissue window to enhance visualization of entrapped osteocartilaginous fragments in the hip joint.

The thin-section computed tomographic (CT) scans of 11 patients with entrapped intra-articular fragments secondary to dislocation or fracture dislocation of the hip are studied. The effects of CT bone and soft-tissue contrast manipulation on the visibility of the intra-articular fragments are demonstrated in both patients and in vitro. When the mechanism of injury and clinical features raise the possibility of entrapped fragments, as in hip dislocation and fracture dislocation, special magnification and image-enhancement techniques are available for re-examining the acetabulum, especially when raw CT data are saved. Thus, index of suspicion and appropriate CT planning can ensure prompt diagnosis and treatment of entrapped intraarticular fragments in the hip joint.

Cartilage, Articular↗

Magnetic resonance imaging after pedicular screw fixation of the spine.

Magnetic resonance imaging (MRI) of the thoracolumbar spine is valuable in the diagnosis of acute and chronic spine injuries. It allows evaluation of the nerve roots, spinal cord, and the supporting bony and ligamentous structures. Magnetic resonance imaging can be used to detect sequelae of spinal cord injury and any mechanical impingement on the spinal cord or nerve roots. Pedicular screw fixation of the spine is becoming the procedure of choice for stabilization of the lumbar spine, yet it limits the postoperative use of MRI because of marked imaging artifacts arising from the ferromagnetic properties of the used stainless steel implants. The authors have compared extensive artifacts produced by the stainless steel implants with those produced by titanium implants. Titanium implants produced fewer artifacts in the spinal canal. The use of MRI compatible materials in thoracolumbar spine stabilization would permit detailed examinations by serial MR imaging.

Alloys↗

Titanium hip implants for improved magnetic resonance and computed tomography examinations.

The value of magnetic resonance imaging (MRI) for assessment of the hip has been demonstrated, particularly in cases of avascular necrosis. Magnetic resonance imaging can be used to provide anatomic evaluation of the femoral head, acetabulum, hip joint, joint fluid, and the surrounding structures. MR examinations of two patients with hip fractures fixed with stainless steel hip implants were compared with nine patients with hip fractures fixed with titanium hip implants, one of which showed avascular necrosis of the femoral head. The titanium implants resulted in less MRI artifacts, allowing for improved depiction of the femoral head and surrounding soft tissue. For this reason titanium fixation devices are recommended as a substitute for stainless steel in the hip joint region in a patient who may need future MR examination.

Bone Nails↗

Assessment of tibial fracture union by 35-45 degrees internal oblique radiographs.

Thirty-five to 45 degrees internal oblique radiographs were used in the assessment of tibial fracture healing. This view is particularly helpful when routine radiographic examinations (anteroposterior and lateral) are nondiagnostic in assessing tibial fracture healing. The technique was helpful in the diagnosis of four occult nonunions as well as in showing the position of a bone graft when used. The authors recommend this view when a decision about tibial fracture healing cannot be made from routine radiographs. They recommend this view before resorting to tomograms of the tibia.

Fractures, Ununited↗

A calcified ligamentum teres mimicking entrapped intraarticular bony fragments in a patient with acetabular fracture.

A motor vehicle accident victim presented with a fractured acetabulum and had apparent entrapped bony intraarticular fragments seen on computed tomography scanning. At surgery, these fragments were found to be a partially avulsed calcified ligamentum teres that was apparently caused by a previous injury of the same hip. Excision of the calcified ligament and surgical stabilization of the acetabulum were performed. A calcified ligamentum teres may be confused with entrapped bony fragments and therefore cause difficulty in the evaluation and management of acetabular fractures.

Acetabulum↗