Characterisation of reversed-phase stationary phases for the liquid chromatographic analysis of basic pharmaceuticals by thermodynamic data.

This paper describes the characterisation of reversed-phase liquid chromatography (RPLC) columns using thermodynamic measurements. Retention versus 1/T data were used to construct Van't Hoff plots. The slope of these plots indicates the standard enthalpy of transfer of the analyte from the mobile to the stationary phase. The standard entropy can be calculated from the intercept. Van't Hoff plots were linear for the investigated RPLC columns, meaning that for basic analytes over the temperature range studied no changes in the retention mechanism occurred. Enthalpies and entropies of transfer of basic analytes from the mobile to the stationary phase revealed information about the types of interaction of protonated and neutral compounds with the stationary phases. However, a clear view using the present set of basic compounds on how these thermodynamic data may explain the observed substantial differences in peak symmetry cannot be given. It is considered that addition of N,N-dimethyloctylamine (DMOA) to the eluent will results in a dynamically coating of the stationary phase. Addition of DMOA to the eluent resulted for protonated basic compounds in a reduction of both enthalpy and entropy. In practice, with DMOA in the eluent symmetrical peaks were obtained. It is assumed that this is due to blocking residual silanols and/or ion exclusion effects.

Chromatography, Liquid↗

Characterisation of reversed-phase liquid chromatography stationary phases for the analysis of basic pharmaceuticals: eluent properties and comparison of empirical test methods.

The reversed-phase liquid chromatographic analysis of basic pharmaceuticals can be problematic. Both the properties of the eluent and the stationary phase can influence the chromatographic performance. Therefore selection of suitable experimental conditions for the analysis of basic compounds can be difficult. This paper shows that the organic modifier and the nature of the buffer influence the eluent properties. Moreover, the nature and amount of modifier also influence the basicity of the analytes. Investigations showed that the nature of the buffer can have a significant influence on retention and peak shape of basic compounds. Test procedures using basic analytes as test probes provided relevant information with respect to selecting columns to analyse basic pharmaceutical compounds. Test procedures using compounds like aniline, phenol and benzene were found to be less suitable.

Chromatography, High Pressure Liquid↗

Gel permeation for the on line removal of proteins from plasma samples prior to HPLC.

Gel permeation chromatography (GPC) has been investigated for the on line removal of proteins from plasma samples prior to their analysis by HPLC. The results show that GPC is a mild and effective way to remove proteins from plasma samples. It can very well be coupled on line to HPLC, providing the solutes are suitable for preconcentration on the analytical column itself or on a small pre-column, after the GPC. Under these conditions excellent reproducibility and accuracy can be obtained.

Blood Proteins↗