High intensity focused ultrasound effect on cardiac tissues: potential for clinical application.

High intensity focused ultrasound (HIFU) is an evolving technology with potential therapeutic applications. Utilizing frequencies of 500 kHz to 10 MHz, HIFU causes localized hyperthermia at predictable depths without injuring intervening tissue. Applications in neurosurgery, urology, oncology and, more recently, cardiology for selective cardiac conduction tissue ablation have been promising. A 'noninvasive' technique for causing localized tissue damage to relieve hemodynamic and life-threatening obstruction in patients with congenital cardiac anomalies could replace more invasive procedures. We, therefore, investigated the ability of HIFU to create lesions in mammalian cardiac tissues ex vivo. Porcine valve leaflet, canine pericardium, human newborn atrial septum, and right atrial appendage were studied. Specimens were mounted and immersed in a water bath at room temperature. Using a 1-MHz phased array transducer, ultrasound energy was applied with an acoustic intensity of 1630 W/cm(2) or 2547 W/cm(2) until a visible defect was created (duration 3 to 25 sec). Macroscopic and microscopic examination demonstrated precise defects ranging from 3 to 4 mm in diameter. No damage was identified to the surrounding tissues. Our study concluded that HIFU can create precise defects in different cardiac tissue without damage to the surrounding tissue. Further investigation is needed to assess potential clinical uses of this technology.

Animals↗

Filter-based coded-excitation system for high-speed ultrasonic imaging.

We have recently presented a new algorithm for high-speed parallel processing of ultrasound pulse-echo data for real-time three-dimensional (3-D) imaging. The approach utilizes a discretized linear model of the echo data received from the region of interest (ROI) using a conventional beam former. The transmitter array elements are fed with binary codes designed to produce distinct impulse responses from different directions in ROI. Image reconstruction in ROI is achieved with a regularized pseudoinverse operator derived from the linear receive signal model. The reconstruction operator can be implemented using a transversal filter bank with every filter in the bank designed to extract echoes from a specific direction in the ROI. The number of filters in the bank determines the number of image lines acquired simultaneously. In this paper, we present images of a cyst phantom reconstructed based on our formulation. A number of issues of practical significance in image reconstruction are addressed. Specifically, an augmented model is introduced to account for imperfect blocking of echoes from outside the ROI. We have also introduced a column-weighting algorithm for minimizing the number of filter coefficients. In addition, a detailed illustration of a full image reconstruction using subimage acquisition and compounding is given. Experimental results have shown that the new approach is valid for phased-array pulse-echo imaging of speckle-generating phantoms typically used in characterizing medical imaging systems. Such coded-excitation-based image reconstruction from speckle-generating phantoms, to the best of our knowledge, have not been reported previously.

Artifacts↗

Ultrasonic focusing through inhomogeneous media by application of the inverse scattering problem.

A new approach is introduced for self-focusing phased arrays through inhomogeneous media for therapeutic and imaging applications. This algorithm utilizes solutions to the inverse scattering problem to estimate the impulse response (Green's function) of the desired focal point(s) at the elements of the array. This approach is a two-stage procedure, where in the first stage the Green's functions is estimated from measurements of the scattered field taken outside the region of interest. In the second stage, these estimates are used in the pseudoinverse method to compute excitation weights satisfying predefined set of constraints on the structure of the field at the focus points. These scalar, complex valued excitation weights are used to modulate the incident field for retransmission. The pseudoinverse pattern synthesis method requires knowing the Green's function between the focus points and the array, which is difficult to attain for an unknown inhomogeneous medium. However, the solution to the inverse scattering problem, the scattering function, can be used directly to compute the required inhomogeneous Green's function. This inverse scattering based self-focusing is noninvasive and does not require a strong point scatterer at or near the desired focus point. It simply requires measurements of the scattered field outside the region of interest. It can be used for high resolution imaging and enhanced therapeutic effects through inhomogeneous media without making any assumptions on the shape, size, or location of the inhomogeneity. This technique is outlined and numerical simulations are shown which validate this technique for single and multiple focusing using a circular array.

Acoustics↗

A hybrid computational model for ultrasound phased-array heating in presence of strongly scattering obstacles.

A computationally efficient hybrid ray-physical optics (HRPO) model is presented for the analysis and synthesis of multiple-focus ultrasound heating patterns through the human rib cage. In particular, a ray method is used to propagate the ultrasound fields from the source to the frontal plane of the rib cage. The physical-optics integration method is then employed to obtain the intensity pattern inside the rib cage. The solution of the matrix system is carried out by using the pseudo inverse technique to synthesize the desired heating pattern. The proposed technique guides the fields through the intercostal spacings between the solid ribs and, thus, minimal intensity levels are observed over the solid ribs. This simulation model allows for the design and optimization of large-aperture phased-array applicator systems for noninvasive ablative thermal surgery in the heart and liver through the rib cage.

Algorithms↗

Multipoint temperature control during hyperthermia treatments: theory and simulation.

A real-time multipoint feedback temperature control system has been designed and implemented with an ultrasound phased-array applicator for hyperthermia. The control parameters are the total power available from the supply and the dwell times at a sequence of preselected heating patterns. Thermocouple measurements are assumed for temperature feedback. The spatial operator linking available heating patterns to temperature measurements is measured at the outset of the treatment and can be remeasured on line an adaptive implementation. A significant advantage of this approach is that the controller does not require a priori knowledge of either the placement of the thermocouples or the power distribution of the ultrasound heating patterns. Furthermore, the control loop uses a proportional integral (PI) gain in conjunction with a singular value decomposition (SVD) of the spatial transfer operator. This approach is advantageous for robust implementation and is shown to properly balance the power applied to the individual patterns. The controller also deals with saturation in the inputs without integrator windup and, therefore, without temperature overshoot. In this paper, we present the theoretical formulation and representative simulation results of the proposed controller. The control algorithm has been verified experimentally, both in vitro and in vivo. A subsequent paper describing these results and the practical implementation of the controller will follow.

Algorithms↗

Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound.

A noninvasive technique for monitoring tissue temperature changes due to heating fields using diagnostic ultrasound is described in this paper. The approach is based on the discrete scattering model used in the tissue characterization literature and the observation that most biological tissues are semi-regular scattering lattices. It has been demonstrated by many researchers and verified by us that the spectrum of the backscattered radio frequency (RF) signal collected with a diagnostic ultrasound transducer from a semi-regular tissue sample exhibits harmonically related resonances at frequencies determined by the average spacing between scatterers along a segment of the A-line. It is shown theoretically and demonstrated experimentally (for phantom, in vitro, and in vivo media) that these resonances change with changes in the tissue temperature within the processing window. In fact, changes in the resonances (delta f) are linearly proportional to changes in the temperature (delta T), with the proportionality constant being determined by changes in the speed of sound with temperature and the linear coefficient of thermal expansion of the tissue. Autoregressive (AR) model-based methods aid in the estimation of delta f. It should be emphasized that this new technique is not a time of flight velocimetric one, so it represents a departure from previously used ultrasonic methods for tissue temperature estimation.

Body Temperature↗

Direct computation of ultrasound phased-array driving signals from a specified temperature distribution for hyperthermia.

This paper presents a new method which obtains ultrasound hyperthermia applicator phased-array element driving signals from a desired temperature distribution. The approach combines a technique which computes array element driving signals from focal point locations and intensities with a new technique which calculates focal point locations and power deposition values from temperature requirements. Temperature specifications appear here as upper and lower bounds within the tumor volume, and a focal point placement algorithm chooses focal patterns capable of achieving the temperature range objective. The linear algebraic structure of the method allows rapid calculation of both the phased-array driving signals and an approximate temperature field response. Computer simulations verify the method with a spherical section array (SSA) for a variety of temperature specifications and blood perfusion values. This scheme, which applies to any phased-array geometry, completes an essential step in both treatment planning and feedback for hyperthermia with ultrasound phased-array applicators.

Acoustics↗

A spherical-section ultrasound phased array applicator for deep localized hyperthermia.

Computer simulation shows that a new ultrasound phased-array with nonplanar geometry has considerable potential as an applicator for deep localized hyperthermia. The array provides precise control over the heating pattern in three dimensions. The array elements form a rectangular lattice on a section of a sphere. Therefore, the array has a natural focus at its geometric center when all its elements are driven in phase. When compared to a planar array with similar dimensions, the spherical-section array provides higher focal intensity gain which is useful for deep penetration and heat localization. Furthermore, the relative grating-lobe level (with respect to the focus) is lower for scanned foci synthesized with this array (compared to a planar array with equal center-to-center spacing and number of elements). This could be the key to the realization of phased-array applicator systems with a realistic number of elements. The spherical-section array is simulated as a spot-scanning applicator and, using the pseudo-inverse pattern synthesis method, to directly synthesize heating patterns overlaying the tumor geometry. A combination of the above two methods can be used to achieve the desired heating pattern in the rapidly varying tumor environment.

Computer Simulation↗

Optimization of the intensity gain of multiple-focus phased-array heating patterns.

A new technique for enhancing the intensity gain at the focal points in multiple-focus patterns is introduced. The new technique is shown to be effective in reducing the interference typically associated with multiple-focus patterns. This reduction in interference patterns allows multiple-focus scanning to generate highly localized heating. Simulation results indicate that multiple-focus scanning not only provides an alternative to single-focus scanning, but also achieves better localization in the heating pattern. The maximization of intensity gain of multiple-focus heating patterns significantly reduces the pre-focal-depth high-temperature regions that can be caused by single-focus scanning. This is shown by computer simulation of a two-dimensional cylindrical-section array (CSA2D) as a heating applicator. Two series of simulations are presented in which different scan trajectories were used to therapeutically heat a small deep-seated target volume. In every case the heating pattern was generated using single-focus scanning and multiple-focus scanning (with and without intensity gain maximization). Multiple-focus scanning with gain maximization offers the best localization of heating to the target volume of the three methods.

Biophysical Phenomena↗

Mode scanning: heating pattern synthesis with ultrasound phased arrays.

Modes, the characteristic symmetric focal patterns of an ultrasound phased array, prove especially useful for hyperthermia. Modes cancel the complex pressure fields exactly along the central axis, eliminating axial constructive interference both proximal and distal to the treatment volume. A simple calculation exploits planar or rotational array symmetry and produces the driving signals which generate modal focal patterns. Results show that temporal mode scanning improves heating patterns considerably, expanding the maximum treatable size of the tumour volume.

Body Temperature↗