The correlation between anterior-posterior translation and cross-sectional area of anterior cruciate ligament reconstructions.

Total anterior-posterior translation is commonly used to assess the integrity of the cruciate ligaments and the success of reconstructive surgery. The purpose of this study was to determine, after surgical reconstruction of the anterior cruciate ligament with a biological graft, if total anterior-posterior translation correlated with graft length, cross-sectional area, or mechanical properties. These factors were investigated by analyzing data from three previous studies. These studies involved replacement of the anterior cruciate ligament in cynomolgus monkeys and goats, with free and vascularized patellar tendon autografts and both patellar tendon and anterior cruciate ligament allografts. Data were available at time periods of 6 and 12 months after surgery. We found statistically significant inverse correlations between the amount of anterior-posterior translation and cross-sectional area of a graft at the time of sacrifice. The Pearson correlation coefficients ranged from -0.966 (p < 0.002) to -0.830 (p < 0.05). We hypothesize that these correlations result from the following mechanism: the increased anterior translation reflects a slack graft; a slack graft is stress shielded by other structures about the knee; the reduced in vivo stresses on the graft modulate cellular metabolism in a way that over time produces a small cross-sectional area.

Analysis of Variance↗

Theoretical analysis of an implantable force transducer for tendon and ligament structures.

A mathematical model was developed for an implantable force transducer to be inserted within the midsubstance of a ligament or tendon. The model was generated by performing both equilibrium and strain-displacement analyses on a metallic, curved beam structure placed within a parallel-fibered tissue. The analysis permitted the transverse pressure acting between the device and fibers to be calculated along with peak device strain and sensitivity (ratio of strain output to axial tissue force). Transducer pressure and transducer strain were expressed in terms of nondimensionalized design factors. A parametric analysis of the key design factors was then performed. The transverse pressure was shown to vary little for large changes in these factors whereas device strain changed markedly. The analysis was verified by a bench test on an example device. Such a model permits a proposed design to be evaluated without having to conduct costly experiments.

Animals↗

Posterior tibial subluxation of the posterior cruciate-deficient knee.

Ten subjects with unilateral posterior cruciate ligament-deficient knees were studied, comparing the knee mechanics of the affected knee with the mechanics of the opposite normal knee. The static squat test was used to determine knee forces and moments through measurements made on roentgenograms. Statistically significant increases occurred in posterior translation of the tibia in all knees at high knee flexion angles, but not uniformly at low knee flexion angles. The results suggest that posterior tibial subluxation occurs in vivo during certain activities of daily living. Posterior tibial subluxation occurred in positions of knee flexion near 70 degrees, establishing a new equilibrium for the system where tibiofemoral joint compression force (approximately four times one-half body weight) remained an order of magnitude greater than tibiofemoral shear forces (approximately 10% of one-half body weight).

Adolescent↗

Effects of gamma irradiation on the initial mechanical and material properties of goat bone-patellar tendon-bone allografts.

The effects of 60Co gamma irradiation on the initial mechanical properties of the composite bone-patellar tendon-bone unit (CU) and the tendon midsubstance (TM) were studied. Frozen specimens were exposed to either 2 or 3 Mrad of gamma irradiation. Paired frozen specimens served as intraanimal controls. Treatment effects on the CU were assessed using four mechanical parameters. Effects on the TM were assessed using four material parameters measured using an optical surface-strain analysis system. The maximum force and strain energy to maximum force of the composite unit were significantly reduced 27% and 40%, respectively, after 3 Mrad of irradiation (p less than .05). Mechanical properties of the CU were not significantly altered, however, following 2 Mrad of irradiation. Based on individual paired contrasts between treatment and control, significant differences were also found in the material properties of the tendon midsubstance. The maximum stress, maximum strain, and strain energy density to maximum stress were significantly reduced following 3 Mrad, but not 2 Mrad, of irradiation. The results provide important "time zero" material property data, which will be useful for later anterior cruciate ligament reconstruction studies using irradiated allograft patellar tendons in the goat model and other animal models as well.

Analysis of Variance↗

Effect of flexion angle on the pressure-volume of the human knee.

The objective of this study was to determine pressure-volume relationships in the human knee. Eight normal knees in eight patients undergoing elective arthroscopic surgery were studied to develop pressure-volume curves at 0 degrees, 15 degrees, 30 degrees, 60 degrees, and 80 degrees of flexion, and measure capsular volume at 0 degrees, 15 degrees, 30 degrees, 45 degrees, 60 degrees, and 80 degrees of flexion. The results showed that capsular volume decreases with flexion, whereas capsular stiffness increases. This suggests that during arthroscopy, flexion with obstructed outflow may cause significant intraarticular pressure and potential rupture of synovial membranes. Our results support the concept of flow rates with low distension pressures for maximum safety.

Adult↗

The effects of in situ freezing on the anterior cruciate ligament. An experimental study in goats.

We developed an in situ freeze-thaw model designed to simulate an ideally placed and oriented autogenous graft of the anterior cruciate ligament. In this model, the anterior cruciate ligament was exposed, and the femoral insertion, tibial insertion, and body of the anterior cruciate ligament were frozen in situ with specially designed freezing probes. Freeze-thaw cycles were repeated five times. We used the technique in thirty-three mature goats to study the biological and biomechanical outcomes of the devitalized and devascularized anterior cruciate ligament at zero, six, and twenty-six weeks after treatment. Thus, the collagen fibers of the simulated autogenous graft remain in normal anatomical position and the simulated graft is fixed under physiological tension. At twenty-six weeks, no statistically significant differences were noted between treated and contralateral control (untreated) ligaments relative to anterior-posterior translation, maximum force to rupture, stiffness in the linear region of the force-length curve, modulus of elasticity in the linear region, strain to maximum stress, or maximum stress. The only statistically significant difference was an increase in cross-sectional area of the ligament. This increase was 22 and 42 per cent greater than that in the control ligaments at six weeks and six months. At six months, the ligaments in the control group had an average mid-cross-sectional area of 17.7 +/- 1.2 square millimeters and the ligaments in the experimental group, 25.2 +/- 3.1 square millimeters. Changes in the size and density of the collagen fibrils also were demonstrated at six months. These observations are in sharp contrast to our previous studies of replacement of the anterior cruciate ligament, in which an allograft of the ligament or an allograft supplemented with a 3M ligament augmentation device (LAD; 3M, St. Paul, Minnesota) was used. In those studies, an average reduction in maximum strength of 75 per cent for the allografts and 50 per cent for the allografts that had a ligament-augmentation device was found at one year. We concluded that devitalized, devascularized anterior cruciate ligaments do not lose strength if the anatomical position and the orientation of the collagen fibers are not altered.

Animals↗

Anterior cruciate ligament replacements: a mechanical study of femoral attachment location, flexion angle at tensioning, and initial tension.

We examined three surgical variables that affect the ability of an anterior cruciate ligament replacement to restore the limit of anterior tibial translation. These were the placement site of the substitute on the femur, the initial tension applied to the replacement, and the flexion angle of the knee at the time of tensioning. An anterior load of 100 N was applied to the tibia. As the knee was flexed, we measured the tensile force in the substitute and the anteroposterior position of the femur relative to the tibia. Placement largely determined whether the force in the replacement increased or decreased with flexion. Placement also largely determined whether the tibia moved anteriorly or posteriorly with flexion compared to its position in the intact knee. The initial tension and the flexion angle at tensioning affected the magnitude of force in the substitute and the magnitude of the change in AP position. They did not affect how force and AP position changed with flexion. Greater increases in force and greater posterior shifts in tibial position were produced by changing the flexion angle at tensioning from 0 degrees to 30 degrees than by increasing the initial tension from 22 to 44 N.

Adult↗

Mechanical properties of primate vascularized vs. nonvascularized patellar tendon grafts; changes over time.

Mechanical properties of patellar tendon autografts used to replace the anterior cruciate ligament (ACL) in the cynomolgus monkey were measured at four time periods up to 1 year. The ACL was replaced in each knee with the medial half of the patellar tendon: as a vascularized graft (VG) on one side and as a nonvascularized or free graft (FG) on the other. Postoperative care consisted of 4 weeks of cast immobilization at 30 degrees flexion followed by unrestricted activity in a large cage. Both grafts showed low stiffness and maximum force at 7 weeks (24% and 16% of ACL control values, respectively), increasing to 57% of control ACL stiffness and 39% of control maximum force by 1 year. Corresponding material properties, modulus and maximum stress, also increased over time, but at 1 year were only 34% and 26% of ACL values, respectively. The results indicate that retaining vascularity does not prevent significant reduction in graft properties that occur postoperatively, nor does it accelerate the return in strength and stiffness. Tissue stiffness, which returns earlier than maximum force and joint anteroposterior (AP) force displacement data, should be routinely reported in any healing study. Finally, in studies of this kind, the large variation in the results makes sampling only one or two animals from each time period unreliable.

Animals↗

Three-dimensional motion analysis of clinical stress tests for anterior knee subluxations.

The three rotations and three translations that comprise total knee motion were simultaneously measured in cadaveric knees during the commonly employed clinical tests for anterior cruciate injury. A second study determined the three-dimensional motions that occurred when known forces and moments were applied. A total of eight whole lower limbs were studied. A 6 degree-of-freedom instrumented linkage (3-D electrogoniometer), rigidly mounted to the tibia and femur, was used. The ligaments sectioned included the lateral extraarticular restraints (iliotibial band, lateral capsule) and the anterior cruciate ligament, both separately and in combination. After sectioning the anterior cruciate ligament alone, anterior displacement of both the medial and lateral tibial condyles increased markedly during the flexion rotation drawer and pivot shift tests. At 30 degrees knee flexion, total anterior-posterior displacement increased 100 percent, but internal-external tibial rotation increased only 15 percent. In all the anterior displacement type of clinical tests (including Lachman's test), there was not a true rigid coupling of knee motions because the examiner controlled the amount of internal tibial rotation and anterior tibial translation. After anterior cruciate sectioning alone, both the lateral and medial tibial condyles displaced anteriorly. Sectioning the medial structures caused additional anterior translation of the medial and lateral tibial condyles. We measured many different combinations of motions that depend on the ligament and capsular structures injured, the clinical test used, and how the clinician performed the test. Differing types of anterior subluxation require that the separate subluxations of the medial and lateral tibial condyles be determined during each stress test.

Cadaver↗

Biomechanics of fascia lata ligament replacements: early postoperative changes in the goat.

Mechanical properties of fascia lata autografts used to replace the anterior cruciate ligament (ACL) in the goat were measured at 0, 2, 4, and 8 weeks after surgery. The ACL was replaced in the right knee of 50 animals divided equally into two groups according to graft fixation technique: (a) two smooth staples at each end, with the tissue pulled back toward the joint over the first staple and (b) reinforced fixation with a spiked bushing placed through the tissue and a 3-cm-long flat polypropylene braid sutured to each end of the graft. Eleven unoperated contralateral knees were tested as controls. All statistically significant effects of the reinforced versus staple fixation were observed at 0 weeks, with the reinforced group showing less anteroposterior (AP) translation of the joint and greater maximum force and stiffness of the femur-graft-tibia units. The reinforced group had increased AP translation and decreased strength and stiffness by 2 weeks after surgery. Increased AP translation resulted primarily from increases in the low-stiffness region of the force-displacement curve (primary AP translation) and to a lesser extent from increased translation in the high-stiffness region (secondary anterior translation). Failures at 0 weeks with the reinforced fixation occurred at the bushing or end of the reinforcing braid, while all but one of the later failures occurred in the tissue mid-substance. In the staple group, maximum force was greater at 8 weeks than at 0 weeks, as the failure locations changed from the fixation to the tissue mid-substance.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Limits of movement in the human knee. Effect of sectioning the posterior cruciate ligament and posterolateral structures.

We applied specific forces and moments to the knees of fifteen whole lower limbs of cadavera and measured, with a six degrees-of-freedom electrogoniometer, the position of the tibia at which the ligaments and the geometry of the joint limited motion. The limits were determined for anterior and posterior tibial translation, internal and external rotation, and varus and valgus angulation from zero to 90 degrees of flexion. The limits were measured in the intact knee and then the changes that occurred with removal of the posterior cruciate ligament, the lateral collateral ligament, the popliteus tendon at its femoral attachment, and the arcuate complex were measured. The cutting order was varied, allowing us to determine the changes in the limits that occurred when each structure was cut alone and the amount of motion of the joint that was required for each structure to become taut and to limit additional motion when the other supporting structures had been removed. Removal of only the posterior cruciate ligament increased the limit for posterior tibial translation, with no change in the limits for tibial rotation or varus and valgus angulation. The additional posterior translation was least at full extension and increased progressively, reaching 11.4 millimeters at 90 degrees of flexion. The progressive increase in posterior translation with flexion was apparently due to slackening of the posterior portion of the capsule, as the translation nearly doubled when the posterolateral structures subsequently were removed. Removal of only the posterolateral extra-articular restraints increased the amount of external rotation and varus angulation. The average increase in external rotation depended on the angle of flexion; it was greatest at 30 degrees of flexion and decreased with additional flexion. At 90 degrees of flexion, the intact posterior cruciate ligament limited the increase in external rotation to only 5.3 degrees, less than one-half of the 13.0-degree increase that occurred at 30 degrees of flexion. Subsequent removal of the posterior cruciate ligament markedly increased external rotation at 90 degrees of flexion, resulting in a total increase of 20.9 degrees. The limit for varus angulation was normal as long as the lateral collateral ligament was intact. When the lateral collateral ligament was cut, the limit increased 4.5 degrees (approximately 4.5 millimeters of additional joint opening) when the knee was partially flexed (to 15 degrees).(ABSTRACT TRUNCATED AT 400 WORDS)

Biomechanical Phenomena↗

Classification of ligament injuries: why an anterolateral laxity or anteromedial laxity is not a diagnostic entity.

To interpret clinical laxity tests, the clinician must apply the kinematic and biomechanical concepts listed in Figure 12-13. These concepts have been briefly introduced here and are discussed in greater detail elsewhere. Figure 12-13 illustrates the importance of first selecting a laxity test to diagnose a specific ligament structure abnormality. The test selected, and the diagnostic information gained, is based on an understanding of the primary and secondary ligamentous restraints which are being tested. It is difficult to guess which ligaments are resisting specific joint displacements; therefore, biomechanical tests must first experimentally determine the restraints. Performing these tests obviates the first level of disagreement that existed when interpretations of clinical laxity tests were based only on "clinical impressions." The results of the laxity tests must be understood and communicated in terms of the six degrees-of-freedom system that determines abnormalities in motion. Resultant joint subluxations are readily understood by examining the medial and lateral tibiofemoral compartments separately. Our bumper model illustrates the different types of anterior subluxations that occur after anterior cruciate disruption. The final diagnosis of a ligament defect must be made in precise anatomic terms. In cases of partial disruption, or after healing occurs, the clinician must analyze the remaining functional capacity of the ligaments. In the future, newer diagnostic machines will provide even more detailed information enabling clinicians to determine the different types of compartmental subluxations under defined loading conditions. These machines will also provide measurements of ligament and joint stiffness. In this way, the functional deficits of the individual ligaments, and the joint as a whole, can be more readily characterized. The concepts that we have presented here can be applied qualitatively by the clinician, and in the future, they can be quantitatively applied. Our goal is to provide the basic scientific and clinical principles upon which the diagnosis and classification of ligament injuries should be based.

Humans↗

Lateral stability of the proximal interphalangeal joint.

Current diagnostic criteria and therapeutic guidelines for injuries to the collateral ligaments of the proximal interphalangeal (PIP) joint are imprecise and vague. Laxity determinations, failure analysis, radiographic stress testing, and microscopic dissections were performed on 112 PIP joints. The lateral collateral ligament (LCL) is the primary restraint to varus and valgus angulation of the PIP joint. Its palmar fibers are tight in joint extension and provide the first line of resistance to lateral angulation. Failure of the LCL almost always occurs proximally in a sequential fashion that begins with the palmar fibers and progresses to the more dorsal bundles. Proximal LCL disruption is followed by separation of the accessory collateral-LCL junction and finally by failure of the distal palmar plate. Midsubstance tears of the LCL are rare. If the lateral stress test shows more than 20 degrees of varus or valgus angulation, the LCL can be presumed to be completely disrupted. Angulation of less than 20 degrees is associated with a 53% chance of partial LCL failure and a 47% chance of complete disruption, but the proper position of the LCL will be maintained by the overlying connective tissues. A clinical investigation will be necessary to define the criteria for surgical intervention.

Cadaver↗

Sensitivity of insertion locations on length patterns of anterior cruciate ligament fibers.

A technique is demonstrated, employing an instrumented spatial linkage, for the determination of the length patterns of discrete fiber bundles within a ligament under controlled loading conditions. The instrumented spatial linkage was used to measure the three-dimensional joint motion. The linkage was also used as a three-dimensional coordinate digitizer to determine the spatial location of bony landmarks and the ligament's insertion areas. The length of pseudo fiber bundles was determined as the straight line distance between bone attachments. A comparison is presented, showing good agreement, between elongation patterns obtained from this method and those measured using an instrumented fine wire cable fiber. A sensitivity analysis was performed to evaluate the influence of tibial and femoral attachment location on the length pattern of fiber bundles of the anterior cruciate ligament. It was found that the relationship between fiber elongation and knee flexion depended strongly on the fibers femoral attachment location but not on its tibial attachment location.

Bone and Bones↗

The variable functional disability of the anterior cruciate ligament-deficient knee.

The goal of the authors has been to define the syndrome of the anterior cruciate ligament-deficient knee. These concepts have been applied to pertinent articles in order to explain the discrepancies and contrasting opinions in the literature. The authors have suggested guidelines for treatment based on the quantification of risk factors and a method for the prediction of the functional disability level of patients. Functional disability is activity level-related and is also related to the type of sport and the intensity level of play. Functional disability is symptomatically expressed by pain, swelling, and giving way, which must be correlated with a specific activity level.

Biomechanical Phenomena↗

On the interpretation of our anterior cruciate ligament data.

Design of a synthetic replacement or selection of a biologic substitute requires detailed knowledge of the mechanical properties of the normal ligament. Femur-anterior cruciate ligament-tibia unit (ACL) data have been frequently used for this purpose, although not always properly. Mechanical properties of the human ACL-bone unit are reviewed. Ligament stiffness, elongation, and energy results are based on grip-to-grip motion and thus include ligament and limited bone deformations. Maximum bone-ligament-bone force in young donors (1730 +/- 66N) is higher than reported previously and represents only ligamentous failures. Methods for measuring tissue dimensions are provided and must be duplicated for obtaining accurate material property data. Bone-ligament-bone strain data are higher than those in reports where midsubstance collagen strains are measured and differ from data obtained on isolated ligaments. The authors have examined many factors that affect ligament-bone unit response. Increasing age weakens the tissue-bone preparation, and only when testing is performed at high rates will ligamentous failures predominate. Use of the authors' data in prosthetic ligament evaluation requires that the material be selected based on ligament bundle properties, the prosthesis be examined under similar testing conditions, and anticipated functional loads and margins of safety be determined.