Quantification of fracture healing with three-dimensional computed tomography.

Quantitative methods are necessary for an objective evaluation of fracture healing. Three-dimensional computed tomography (CT) for the measurement of callus volume and density could be such a method and was investigated in an animal model. In 23 goats a closed tibial fracture was created and stabilized with a cast. The animals were killed at 2, 4 and 6 weeks for radiographical, CT and biomechanical analysis. From the CT scans a three-dimensional reconstruction of the callus was made to measure its volume and mean density. At 2 weeks the callus volume had already reached its maximum. In contrast, callus density, torsional strength and torsional stiffness increased over time (P < 0.0001, analysis of variance, ANOVA). Multiple regression analysis showed that the callus volume was not related to the torsional properties. However, callus density was a significant explanatory variable for both torsional strength (R2 = 0.72, P < 0.0001) and torsional stiffness (R2 = 0.82, P < 0.0001). Therefore, callus density as measured by three-dimensional CT is a predictor of the extent of fracture consolidation. CT with three-dimensional reconstruction of the callus seems a valid technique for the quantification of fracture healing.

Analysis of Variance↗

Representative assessment of long bone shaft biomechanical properties: an optimized testing method.

Whole bone bending tests are commonly used in mechanical evaluation of long bones. Reliable information about the midshaft can only be obtained if the bending moment is uniformly distributed along the shaft, and if the distribution of the bending stress is not adversely influenced by rigid clamping of the bone ends. A testing device was developed to determine bending stiffness of long bones in 24 directions, perpendicular to the bone axis. For optimal distribution of bending moment and stress, four-point bending was performed, and bone ends were simply supported, not rigidly clamped. The method was validated by repeated testing of a stainless steel rod, and a sheep femur. Left-right ratios were assessed twice in 2 groups of 5 sheep: one control group, and one group in which the left femur was stabilized with a stainless steel interlocking nail for 2.5 yr, after a midshaft osteotomy. Test results obtained with the steel rod reproducibly were close to predicted values. Measurements with the sheep femurs were reproducible and precise for 3 of the 4 parameters of the bending test. Stiffness parameters were significantly higher in the operated sheep than in the control group. We conclude that the method described here provides accurate and reproducible information, which is representative for the long bone shaft.

Animals↗

Biodegradable interlocking nails for fracture fixation.

Serious problems such as stress shielding, allergic reactions, and corrosion are associated with the use of metallic fracture fixation devices in fractured long bones. Metal implants often are removed during a second retrieval operation after fracture healing has completed. A biocompatible implant that degrades slowly during implantation would obviate the need for a second operation and save the patient from considerable physical, psychologic, and financial discomfort. The biodegradable implant must provide the fractured limb sufficient support for a certain time, allowing early loading. A gradual transfer of load from the biodegradable implant to the bone would result in a better product of bone healing and avoid stress shielding. In an animal model using adult sheep, two types of biodegradable polymer interlocking nails were tested in comparison with a stainless steel interlocking nail. Fracture healing, mechanical properties of the bones, degradation behavior in vivo and in vitro, and tissue response were monitored during a 2 1/2-year followup study. To detect shifts in acid base relations caused by the release of acid compounds, pH measurements were performed. Fracture healing was unimpaired, and the mechanical test results of all three groups were excellent. Histologic analysis showed a mild inflammatory response, but no pH shifts were observed. The results of this study justify additional research on these promising materials.

Absorbable Implants↗