Improving mammographic decision accuracy by incorporating observer ratings with interpretation time.

Mammography is currently the most established technique for the early detection of breast cancer. However, mammography would benefit from further improvements as it does produce some errors, such as not finding all early-stage cancers. The objectives of this study were first, to measure the timing of correct and incorrect reading decisions in mammography and second, to exploit those dependencies to improve accuracy in mammographic interpretation. To address these objectives, an experiment was conducted where experienced breast imaging radiologists reviewed 400 mammographic regions equally divided among images that contained simulated benign masses, malignant masses, malignant microcalcifications and no lesions. The experiment recorded the radiologists' decision as well as the length of time the mammogram was interpreted in. The experiment results showed that incorrect detection as well as incorrect classification decisions were associated with longer interpretation times (p<0.0001). The timing results were used to create a model that would flag cases for review that had a higher probability of error. The flagged cases had a median accuracy drop of 13% for detection decisions and 16% for classification decisions compared with unflagged cases. This suggests that interpretation time can be incorporated into mammographic decision-making in order to identify cases with higher probabilities of perceptual error that require further review.

Breast Neoplasms↗

Luminance and contrast performance of liquid crystal displays for mammographic applications.

Liquid crystal displays (LCDs) are gradually replacing cathode-ray tubes (CRTs) as the primary means of electronic display of digital radiographs. The transition from CRT to LCD is fueled by advantages of the LCD technology such as enhanced maximum luminance and smaller form factor. This transition is expected to extend to digital mammography as well. The purpose of this study was to report the on-axis luminance and contrast performance of five medical-grade LCDs in terms of compliance with the DICOM grayscale display function (GSDF) and AAPM TG18 guidelines. The display devices included two 3 Mpx monochrome LCDs (Planar Dome C3, and NDS 20.8" Nova), two 5 Mpx monochrome LCDs (NDS 21.3" Nova, and Totoku ME511L), and one 9 Mpx color LCD (IBM T221). The on-axis luminance values were measured at all 8-bit driving levels using the TG18-LN test patterns and a baffled luminance meter and the results averaged. The luminance data were analyzed according to the AAPM TG18 methodology. The measured L(min), L(max), mean DeltaJND/Deltap, and maximum local deviation in DeltaJND/Deltap from GSDF, kappa(256), ranged within 0.43-0.87 cd/m(2), 263-715 cd/m(2), 2.15-2.72, and 0.79-1.46 intervals, respectively. While the values varied notably between different devices, all devices conformed to the TG18 criteria for primary class displays in terms of on-axis luminance response, and thus judged suitable for mammographic applications from on-axis luminance standpoint. Notwithstanding the findings, other factors such as matrix size, angular response, and color functionality should further be taken into consideration.

Breast Neoplasms↗

Performance evaluation of computed radiography systems.

Recommended methods to test the performance of computed radiography (CR) digital radiographic systems have been recently developed by the AAPM Task Group No. 10. Included are tests for dark noise, uniformity, exposure response, laser beam function, spatial resolution, low-contrast resolution, spatial accuracy, erasure thoroughness, and throughput. The recommendations may be used for acceptance testing of new CR devices as well as routine performance evaluation checks of devices in clinical use. The purpose of this short communication is to provide a tabular summary of the tests recommended by the AAPM Task Group, delineate the technical aspects of the tests, suggest quantitative measures of the performance results, and recommend uniform quantitative criteria for the satisfactory performance of CR devices. The applicability of the acceptance criteria is verified by tests performed on CR systems in clinical use at five different institutions. This paper further clarifies the recommendations with respect to the beam filtration to be used for exposure calibration of the system, and the calibration of automatic exposure control systems.

Calibration↗

Evaluation of a quality control phantom for digital chest radiography.

RATIONALE AND OBJECTIVES: To examine the effectiveness and suitability of a quality control (QC) phantom for a routine QC program in digital radiography. MATERIALS AND METHODS: The chest phantom consists of copper and aluminum cutouts arranged to resemble the appearance of a chest. Performance of the digital radiography (DR) system is evaluated using high and low contrast resolution objects placed in the "heart," "lung," and "subdiaphragm" areas of the phantom. In addition, the signal levels from these areas were compared to similar areas from clinical chest radiographs. RESULTS: The test objects included within the phantom were effective in assessing image quality except within the subdiaphragm area, where most of the low contrast disks were visible. Spatial resolution for the DR systems evaluated with the phantom ranged from 2.6 lp/mm to 4 lp/mm, falling within the middle of the line pair range provided. The signal levels of the heart and diaphragm regions relative to the lung region of the phantom were significantly higher than in clinical chest radiographs (0.67 versus 0.21 and 0.28 versus 0.10 for the heart and diaphragm regions, respectively). The heart-to-diaphragm signal level ratio, however, was comparable to those in clinical radiographs. CONCLUSION: The findings suggest that the attenuation characteristics of the phantom are somewhat different from actual chests, but this did not appear to affect the post-processing used by the imaging systems and usefulness for QC of these systems. The qualitative and quantitative measurements on the phantom for different systems were similar, suggesting that a single phantom can be used to evaluate system performance in a routine QC program for a wide range of digital radiography systems. This makes the implementation of a uniform QC program easier for institutions with a mixture of different digital radiography systems.

Humans↗

Numerical simulation of a TLD pulsed laser-heating scheme for determination of shallow dose and deep dose in low-LET radiation fields.

A new method is described to determine the depth-dose distribution in low-LET radiation fields using a thick thermoluminescent dosimeter (TLD) with a pulsed laser-heating scheme to obtain TL glow output. The computational simulation entails heat conduction and glow curve production processes. An iterative algorithm is used to obtain the dose distribution in the detector. The simulation results indicate that the method can predict the shallow and deep dose in various radiation fields with relative errors less than 20%.

Journal Article↗

Health physics consequences of out-patient treatment of non-Hodgkin's lymphoma with 131I-radiolabeled anti-B1 antibody.

The Medical University of South Carolina is currently participating in clinical trials of 131I radiolabeled Anti-B1 antibody for treatment of Non-Hodgkin's lymphoma. Under current South Carolina Department of Health and Environmental Control regulatory guidelines,; these patients are required to be admitted to the hospital and to remain as inpatients until the whole body burden is <30 mCi or the exposure rate measured 1 m from the patient is <5 mR h(-1). We demonstrate that these patients can be released in accordance with the new recommended guidelines of the Nuclear Regulatory Commission for the release of patients containing radioactive materials in compliance with all radioactive material and public dose standards. This benefits these patients by reducing their risk of infection and other hospital insults and by reducing the length of hospitalizations. Further, unnecessary hospital admissions are decreased, and the overall cost of healthcare delivery for these patients is significantly reduced.

Adult↗

Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems.

The purpose of this study was to compare the image quality for a digital storage phosphor system using 1760 x 2140 (2k) and 3520 x 4280 (4k) image arrays. Measurements were made on a chest radiography system (Fuji FCR-9501) with special provisions to be operated in both 2k (standard) and 4k (HQ) modes. Presampled modulation transfer functions (MTF) were measured using an edge method. Noise power spectra (NPS) were determined for different input exposures by two-dimensional Fourier analysis. These measures along with exposure measurements and an x-ray spectral model were used to determine the frequency-dependent detective quantum efficiency DQE (f) of the system for the 4k and the 2k modes. The magnitude of the NPS for the 4k mode was about 1/2 that of the 2k mode. A MTF value of 0.5 was found at 1.25 cycles/mm for the 4k system and 1.50 cycles/mm for the 2k system. The 4k images had an extended MTF of 0.1 at 4.5 cycles/mm in the plate-scan direction. Overall, the DQE (f) of the 4k mode was slightly better than that for the 2k mode by about 0.02 due primarily to its better noise characteristics.

Biophysical Phenomena↗

Detection of subtle lung nodules: relative influence of quantum and anatomic noise on chest radiographs.

PURPOSE: To assess the relative influence of quantum mottle and structured lung patterns (anatomic noise) on the detection of subtle lung nodules on chest radiographs. MATERIALS AND METHODS: Sixty 8 x 8-cm lung pattern images were extracted from digital chest radiographs in healthy individuals. Sixty quantum mottle images of the same size and quantum noise level were extracted from uniformly exposed digital radiographs. Simulated nodules with various peak contrast-diameter products (CD) that emulated subtle tissue-equivalent lung nodules were numerically superimposed at the center on three-fourths of the images. Printouts were independently viewed and scored by five experienced radiologists. The area under the receiver operating characteristic curve (Az) was estimated as a measure of the detectability of the nodules. RESULTS: At a fixed observer performance level (e.g., Az = 0.8), much smaller and lower-contrast nodules were detected on quantum mottle images (1-mm diameter, CD = 0.01 mm), compared with those on anatomic images (4.5-mm diameter, CD = 0.20 mm). The findings generally agreed with the signal-to-noise ratio calculations based on statistical observer models. CONCLUSION: The detection of subtle lung nodules on chest radiographs is limited by anatomic noise.

Adult↗

A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

The modulation transfer function (MTF) of radiographic systems is frequently evaluated by measuring the system's line spread function (LSF) using narrow slits. The slit method requires precise fabrication and alignment of a slit and high radiation exposure. An alternative method for determining the MTF uses a sharp, attenuating edge device. We have constructed an edge device from a 250-microm-thick lead foil laminated between two thin slabs of acrylic. The device is placed near the detector and aligned with the aid of a laser beam and a holder such that a polished edge is parallel to the x-ray beam. A digital image of the edge is processed to obtain the presampled MTF. The image processing includes automated determination of the edge angle, reprojection, sub-binning, smoothing of the edge spread function (ESF), and spectral estimation. This edge method has been compared to the slit method using measurements on standard and high-resolution imaging plates of a digital storage phosphor (DSP) radiography system. The experimental results for both methods agree with a mean MTF difference of 0.008. The edge method provides a convenient measurement of the presampled MTF for digital radiographic systems with good response at low frequencies.

Computer Simulation↗

Simulation of subtle lung nodules in projection chest radiography.

PURPOSE: To measure the radiologic characteristics of subtle lung nodules and develop nodule phantoms that simulate these characteristics. MATERIALS AND METHODS: From a database of chest radiographs, 16 radiographs that showed confirmed subtle lung nodules were selected. The optical density values surrounding each nodule were obtained, and the radiologic characteristic of the nodules were evaluated. A set of Teflon nodule phantoms with similar x-ray transmission and variability was designed and fabricated. The contrast characteristics of the images of the nodule phantoms were measured. RESULTS: Most of the subtle nodules appeared to have diffuse edges with Gaussian-like contrast profiles. The contrast and size characteristics of the nodule phantom images fulfilled the design criteria within a 4% deviation. CONCLUSION: The radiologic pattern of subtle lung nodules is poorly simulated by nodule phantoms with simple spherical or disk shapes. The nodule phantoms in this study produce realistic radiographic patterns with an energy-dependent attenuation equivalent to that of tissue. The nodule phantoms are intended for use in experiments involving human subjects.

Humans↗

Sensitivity of a mixed field dosimetry algorithm to uncertainties in thermoluminescent element readings.

An error analysis of the effects of the algorithms used to resolve the deep and shallow dose components for mixed fields from multi-element thermoluminescent (TLD) badge systems was undertaken for a commonly used system. Errors were introduced independently into each of the four element readings for a badge, and the effects on the calculated dose equivalents were observed. A normal random number generator was then utilized to introduce simultaneous variations in the element readings for different uncertainties. The Department of Energy Laboratory Accreditation Program radiation fields were investigated. Problems arising from the discontinuous nature of the algorithm were encountered for a number of radiation sources for which the algorithm misidentified the radiation field. Mixed fields of low energy photons and betas were found to present particular difficulties for the algorithm. The study demonstrates the importance of small fluctuations in the TLD element's response in a multi-element approach.

Algorithms↗

A limited bibliography of the Federal Government-funded human radiation experiments.

From the early 1940's thousands of U.S. citizens have been the subjects of federally supported scientific experiments that involved the administration of ionizing radiation or radioactive substances. Recently, many questions have been raised regarding the nature, scientific value, and ethics of these experiments. Although the results of many of the early human experiments involving radiation have been crucial to the establishment of nuclear medicine, radiation therapy, and radiological protection standards, the underlying ethical basis for a small number of these studies is being questioned. A thorough analysis of these studies and their ethical basis is beyond the scope of this article. Rather, in order to quickly provide the health physics community with some of the available resources in the open literature, a list of bibliographic citations of the 47 studies primarily funded by the Atomic Energy Commission (AEC) and other predecessors of the Department of Energy is presented and briefly summarized. A classification scheme for the human radiation experiments is also developed.

Bioethics↗

Chest radiographic image quality: comparison of asymmetric screen-film, digital storage phosphor, and digital selenium drum systems--preliminary study.

Conventional screen-film radiography does not display all regions of the thorax satisfactorily. Three chest radiographic techniques display both the lung and the mediastinum with good contrast. These techniques are asymmetric screen-film (ASF), digital storage phosphor (DSP), and digital selenium drum (DSD) imaging. ASF systems use two asymmetric screen-film combinations to produce a wide-latitude image of the thorax with good contrast in the lungs. In DSP systems, image data are acquired digitally with a wide dynamic range by using the optical output of a photostimulable phosphor plate; in DSD systems, the wide-range digital image data are acquired by using the electronic charge generated on a drum coated with a thin layer of amorphous selenium. The appearance of a DSP or DSD radiograph is then determined by user-selected image processing operations: tone scaling, spatial frequency processing, and dynamic range compensation. Digital chest radiographs processed with strong regional equalization provide both excellent contrast in the lungs and effective display of the mediastinum and chest wall. At visual comparison, the high lung contrast and good mediastinal, retrocardiac, and subdiaphragmatic detail provided by the DSD method distinguish it from the other two methods.

Humans↗