2 recordsLinked to original sources

Motion correction for improved target localization with on-board cone-beam computed tomography.

On-board imager (OBI) based cone-beam computed tomography (CBCT) has become available in radiotherapy clinics to accurately identify the target in the treatment position. However, due to the relatively slow gantry rotation (typically about 60 s for a full 360 degrees scan) in acquiring the CBCT projection data, the patient's respiratory motion causes serious problems such as blurring, doubling, streaking and distortion in the reconstructed images, which heavily degrade the image quality and the target localization. In this work, we present a motion compensation method for slow-rotating CBCT scans by incorporating into image reconstruction a patient-specific motion model, which is derived from previously obtained four-dimensional (4D) treatment planning CT images of the same patient via deformable registration. The registration of the 4D CT phases results in transformations representing a temporal sequence of three-dimensional (3D) deformation fields, or in other words, a 4D model of organ motion. The algorithm was developed heuristically in two-dimensional (2D) parallel-beam geometry and extended to 3D cone-beam geometry. By simulations with digital phantoms capable of translational motion and other complex motion, we demonstrated that the algorithm can reduce the motion artefacts locally, and restore the tumour size and shape, which may thereby improve the accuracy of target localization and patient positioning when CBCT is used as the treatment guidance.

Algorithms↗

Radiation dose reduction in four-dimensional computed tomography.

Four-dimensional (4D) CT is useful in many clinical situations, where detailed abdominal and thoracic imaging is needed over the course of the respiratory cycle. However, it usually delivers a larger radiation dose than the standard three-dimensional (3D) CT, since multiple scans at each couch position are required in order to provide the temporal information. Our purpose in this work is to develop a method to perform 4D CT scans at relatively low current, hence reducing the radiation exposure of the patients. To deal with the increased statistical noise caused by the low current, we proposed a novel 4D penalized weighted least square (4D-PWLS) smoothing method, which can incorporate both spatial and phase information. The 4D images at different phases were registered to the same phase via a deformable model, thereby, a regularization term combining temporal and spatial neighbors can be designed for the 4D-PWLS objective function. The proposed method was tested with phantom experiments and a patient study, and superior noise suppression and resolution preservation were observed. A quantitative evaluation of the benefit of the proposed method to 4D radiotherapy and 4D PET/CT imaging are under investigation.

Biophysical Phenomena↗