Publications and source records attributed to E Sloth.

At least 19 recordsLinked to original sources

Strain rate derived from color Doppler myocardial imaging for assessment of fetal cardiac function.

OBJECTIVE: Color Doppler myocardial imaging (CDMI) is a new multigated method that allows direct analysis of myocardial motion. It is superior to pulsed-wave tissue Doppler in its ability to generate new and important indices of myocardial function such as strain, strain rate and tissue tracking. The purpose of this study was to assess the feasibility of CDMI in the fetal heart. METHODS: Three normal fetuses of gestational ages 20 + 1, 28 + 1 and 36 + 0 weeks and a fetus of 20 + 3 weeks with aortic valve atresia were studied. Velocity data were acquired from the apical four-chamber view using a Vivid 7 ultrasound platform with integrated software for CDMI and with frame rates around 200/s. Data were post-processed using dedicated software and with the sample area placed at the subvalvular and middle part of the septum and the ventricular walls. RESULTS: CDMI was feasible in all fetuses. The fetus with aortic valve atresia had severely reduced strain rate of the left ventricular wall. CONCLUSIONS: Using this new technique it is possible to obtain information on the global and regional contractility of the fetal heart and thereby gain new insights into the physiology of the fetal cardiovascular system. CDMI is a promising new method for monitoring at-risk fetuses.

Aortic Valve↗

Transthoracic echocardiography for cardiopulmonary monitoring in intensive care.

BACKGROUND AND OBJECTIVE: To evaluate the feasibility of an abbreviated focus assessed transthoracic echocardiographic protocol, consisting of four standardized acoustic views for cardiopulmonary screening and monitoring. METHODS: The protocol was applied in 210 patients in a 20-bed multidisciplinary intensive care unit in a university hospital. When inconclusive, an additional transoesophageal echocardiographic examination was performed. Diagnosis, indication, acoustic window, position and value were recorded. Significant pathology, load, dimensions and contractility were assessed. RESULTS: Two-hundred-and-thirty-three transthoracic and four transoesophageal echoes were performed. The protocol provided usable images of the heart in 97% of the patients, 58% subcostal, 80% apical and 69% parasternal. Images through one window were obtainable in 23%, through two windows in 41% and through three windows in 34%. In 227 patients (97.4%) the focus assessed echo protocol contributed positively. In 24.5% of cases the information was decisive, in 37.3% supplemental and in 35.6% supportive. CONCLUSIONS: By means of an abbreviated, focus assessed transthoracic echo protocol it is feasible to visualize the haemodynamic determinants for assessment and optimization. One or more useful images are obtainable in 97% of critically ill patients.

Adult↗

Transoesophageal echocardiographic monitoring during paediatric cardiac surgery: obtainable information and feasibility in 532 children.

BACKGROUND: We hypothesized that transoesophageal echocardiography (TOE) performed by the anaesthesiologists would be beneficial for monitoring purposes during paediatric cardiac surgery. We present the results for the first 5 years in 532 consecutive children. METHODS: The probe was successfully inserted in 99% of cases and remained in the oesophagus for 211 min on average (range 10-555 min). RESULTS: Insignificant valve leak, single- or biventricular failure and volume depletion were the most common new findings due to TOE. Changes in inotropic strategy and volume replacement were the most frequent interventions. In 45% of the cases, new information was disclosed and, in a total of 8% of cases, decisive information was provided. Except for tracheal extubation in one child who was uneventfully reintubated, no severe complications were identified. CONCLUSIONS: These data stress the safety and ease of performing TOE in children undergoing cardiac surgery. There is evidence for benefit from TOE findings to potentially enhance the therapeutic basis.

Adolescent↗

Doppler flow measurement using surface integration of velocity vectors (SIVV): in vitro validation.

Blood flow measurement using an improved surface integration of velocity vectors (SIVV) technique was tested in in vitro phantoms. SIVV was compared with true flow (12-116 mL/s) in a steady-state model using two angles of insonation (45 degrees and 60 degrees ) and two vessel sizes (internal diameter = 11 and 19 mm). Repeatability of the method was tested at various flow rates for each angle of insonation and vessel. In a univentricular pulsatile model, SIVV flow measured at the mitral inlet was compared to true flow (29-61 mL/s). Correlation was excellent for the 19-mm vessel (r(2)= 0.99). There was a systematic bias but close limits of agreement (mean +/- 2 SD = -24.1% +/- 7.6% at 45 degrees; +16.4% +/- 11.0% at 60 degrees ). Using the 11-mm vessel, a quadratic relationship was demonstrated between between SIVV and true flow (r(2) = 0.98-0.99), regardless of the angle of insonation. In the pulsatile system, good agreement and correlation were shown (r(2) = 0.94, mean +/- 2 SD = -4.7 +/- 10.1%). The coefficients of variation for repeated SIVV measurements ranged from 0.9% to 10.3%. This method demonstrates precision and repeatability, and is potentially useful for clinical measurements.

Blood Flow Velocity↗

Pediatric cardiac output measurement using surface integration of velocity vectors: an in vivo validation study.

OBJECTIVE: To test the accuracy and reproducibility of systemic cardiac output (CO) measurements using surface integration of velocity vectors (SIVV) in a pediatric animal model with hemodynamic instability and to compare SIVV with traditional pulsed-wave Doppler measurements. DESIGN: Prospective, comparative study. SETTING: Animal research laboratory at a university medical center. SUBJECTS: Eight piglets weighing 10-15 kg. INTERVENTIONS: Hemodynamic instability was induced by using inhalation of isoflurane and infusions of colloid and dobutamine. MEASUREMENTS: SIVV CO was measured at the left ventricular outflow tract, the aortic valve, and ascending aorta. Transit time CO was used as the reference standard. RESULTS: There was good agreement between SIVV and transit time CO. At high frame rates, the mean difference +/- 2 SD between the two methods was 0.01+/-0.27 L/min for measurements at the left ventricular outflow tract, 0.08+/-0.26 L/min for the ascending aorta, and 0.06+/-0.25 L/min for the aortic valve. At low frame rates, measurements were 0.06+/-0.25, 0.19+/-0.32, and 0.14+/-0.30 L/min for the left ventricular outflow tract, ascending aorta, and aortic valve, respectively. There were no differences between the three sites at high frame rates. Agreement between pulsed-wave Doppler and transit time CO was poorer, with a mean difference +/- 2 SD of 0.09+/-0.93 L/min. Repeated SIVV measurements taken at a period of relative hemodynamic stability differed by a mean difference +/-2 SD of 0.01+/-0.22 L/min, with a coefficient of variation = 7.6%. Intraobserver coefficients of variation were 5.7%, 4.9%, and 4.1% at the left ventricular outflow tract, ascending aorta, and aortic valve, respectively. Interobserver variability was also small, with a coefficient of variation = 8.5%. CONCLUSIONS: SIVV is an accurate and reproducible flow measurement technique. It is a considerable improvement over currently used methods and is applicable to pediatric critical care.

Animals↗

Convective warming blankets improve peroperative heat preservation in congenital heart surgery.

Peroperative heat preservation, following hypothermic cardiopulmonary bypass (CPB) in children, has always been a challenge to the anaesthetist. We studied the efficiency of a convective heating system on peroperative heat preservation in 50 children undergoing congenital heart surgery. Twenty-five children, rewarmed by CPB and heating mattress, were randomly selected (Group 1). Another 25 children, rewarmed by CPB, heating mattress and convective warming blankets in addition (Group 2), were selected so the two groups were comparable regarding age, weight and anaesthetic management. The central and peripheral temperatures were measured during bypass, at the end of bypass and at the end of operation. A retrospective evaluation showed that during bypass the peripheral temperature was significantly lower in Group 2 than in Group 1, with no significant difference in central temperature. At the end of bypass there was no significant difference between the two groups. At the end of operation the central and peripheral temperatures were significantly higher in Group 2. In conclusion convective warming blankets are effective in keeping or even raising the temperature following congenital heart surgery.

Body Temperature↗

Diameter and cross-sectional area relationship of the human main pulmonary artery. Evaluated by epicardial echocardiography.

Correct assessment of vessel cross-sectional area (CSA) is essential for reliable cardiac output (CO) measurements by means of pulsed Doppler echocardiography. In 23 patients who underwent coronary artery bypass grafting (CABG) the main pulmonary artery CSA and diameter changes were assessed by epicardial two-dimensional echocardiography using a 7.5 MHz cm2 transducer. Our data indicate that the shape of the pulmonary artery changes over time. Time averaged CSA ranged from 3.51 to 8.29 cm2 (mean 5.04 cm2; SD 1.3 cm2) and the distensibility varied from 13% to 33% (mean 23%; SD 5%). The limits of agreement for the CSA calculated from the most suitable diameter (when assuming vessel circularity) and the corresponding traced CSA (reference value) during peak systole were -0.16 +/- 0.56 cm2 (mean +/- 2SD). In this idealized set-up (not clinically implementable) the maximal discrepancy between the calculated and traced CSA was 12% and 17% during peak systole and diastole, respectively. Therefore, a potential error in CO determination is incurred if CSA is assessed from a single diameter.

Adult↗

Where to place the Doppler sample volume in the human main pulmonary artery: evaluated from magnetic resonance phase velocity maps.

OBJECTIVE: To give recommendations for the placement of Doppler sample volumes for blood flow assessment in the human main pulmonary artery. METHODS: In 10 healthy volunteers MR-phase velocity measurements were obtained and computing of the mean temporal blood velocity data was performed to guide single point Doppler velocity recordings. RESULTS: The mean temporal blood velocity profiles were consistently skewed with the lowest blood velocities towards the inferior/right vessel wall. Blood velocity indices (ratio of point to mean velocities, where a point equals a square of 4 pixels) varied considerably with the lowest indices located towards the inferior/right vessel wall. A centrally located fictive sample volume revealed an average blood velocity index value (average of all 10 subjects) of 1.08 (range 0.99-1.25; s.d. 0.08) where the central point was defined at maximum systole, and a value of 1.13 (range 0.97-1.34; s.d. 0.11) when the central point was defined in end-diastole. The mean of multiple sample volumes along the inferior/right to superior/left diameter revealed a blood velocity index of 1.01 (range 0.87-1.21; s.d. 0.09) in systole and 1.03 (range 0.87-1.19; s.d. 0.09) in diastole. CONCLUSIONS: For practical clinical purposes, single point estimation of the mean blood velocity in the pulmonary artery should be performed centrally. The use of multiple sample volumes placed along the inferior/right to superior/left diameter improves the mean velocity estimate in healthy volunteers. Further studies should be conducted to reinforce the basis for Doppler velocity recording in the diseased human pulmonary artery as well as to investigate other important determinants of Doppler-derived CO, namely angle of insonation and assessment of the cross-sectional area.

Adult↗

Transesophageal multiplane imaging of the human pulmonary artery: a comparison of MRI and multiplane transesophageal two-dimensional echocardiography.

OBJECTIVE: To evaluate the anatomical relationship between the esophagus and pulmonary artery including assessment of the correct transesophageal Doppler insonation angle into the mid-pulmonary artery trunk. METHODS: We evaluated the anatomical relationship between the esophagus and pulmonary artery (PA) from comparable magnetic resonance (MR) and transesophageal echocardiographic (TEE) multiple two-dimensional images (0 degree, 45 degrees, 90 degrees and 135 degrees clockwise rotation of the standard transverse scanning plane when seen bearfrom the esophagus) obtained in 10 healthy, young volunteers. RESULTS: The main PA could be visualized with both techniques in all 10 volunteers and provided highly identical images of good quality. A mean insonation angle of 35 degrees (range 26 degrees-46 degrees) for a fictive esophageal Doppler beam into the main PA was disclosed. The PA trunk was short with a mean length of 23.4 mm (range 17-30 mm). CONCLUSIONS: These anatomical data contradict the general assumption of alignment of the pulmonary artery and the transesophageal Doppler beam. Angle correction should be applied in the clinical setting using MTEE by rotation of the scanning plane to approximately 45 degrees. Ignoring the insonation angle of approximately 35 degrees may cause 20% underestimation of blood flow velocity and cardiac output in the PA.

Adult↗

The impact of ischemic heart disease on main pulmonary artery blood flow patterns: a comparison between magnetic resonance phase velocity mapping and transesophageal color Doppler.

OBJECTIVE: To give a detailed evaluation on main pulmonary artery blood velocity patterns, in patients with ischemic heart disease and to provide recommendations for pulsed Doppler sample volume placement, in order to optimize cardiac output estimation. METHODS: Using magnetic resonance phase and esophageal color Doppler velocity mapping in 12 patients with ischemic heart disease and undergoing coronary artery by-pass grafting, very similar data on pulmonary artery blood velocity patterns were provided for comparison with each other. RESULTS: Peak blood velocities were located in the inferior half of the main pulmonary artery cross-sectional area. Early after peak systole the highest velocities shifted towards the superior/left (major curvature) with a simultaneous decrease in velocities inferiorly. The velocity decrease further evolved into retrograde flow to the inferior/right (minor curvature). This feature was significantly enhanced compared to earlier findings in healthy volunteers. The mean temporal blood velocity profiles were asymmetrically skewed, thereby giving unreliable cardiac output estimates based on single point Doppler blood velocity recordings. The error incurred may amount to more than 100% in extreme cases. According to our data, optimal assessment of cardiac output should be based on multiple sample volumes placed along the inferior/right to superior/left diameter. CONCLUSIONS: MR-phase velocity mapping and multiplane transesophageal color Doppler recordings provided similar blood velocity patterns in patients with ischemic heart disease. The skewness of the mean temporal blood velocity profile is enhanced compared with healthy subjects, resulting in error in the assessment of CO by means of pulsed Doppler echocardiography. By using multiple Doppler sample volumes, the error can be minimized.

Aged↗

New semiautomated Doppler method for quantification of volumetric flow: intraoperative validation with multiplane transesophageal color Doppler imaging.

We have validated a new semiautomated method for quantification of volumetric flow applied to multiplane transesophageal color Doppler mapping. This Doppler technique assumes only the incompressibility of the fluid and includes variations of flow area. By computing velocity vectors across a surface normal to the point of scanning, volumetric flow can be measured independently of the angle of incidence between the ultrasonic beam and the direction of blood flow. Mitral valvular flow rate was measured during surgery by transesophageal color Doppler echocardiography in 27 patients undergoing coronary artery bypass grafting at 45 sets of observations. The results were compared with those obtained by the thermodilution technique. The mean of the differences between the thermodilution technique and color Doppler echocardiography was 0.06 +/- 0.866 L/min for the mitral valvular flows (mean of differences [thermodilution-color Doppler] &/- 2 SDs of differences). Thus mitral valvular volumetric flow measured by this color Doppler method showed a close agreement to the thermodilution technique during surgery.

Blood Flow Velocity↗

Movement of pulmonary artery catheters.

Intraluminal movements of pulmonary artery catheters are seldom considered, although they may have a significant impact on flow measurement and safety. The purpose of this study was to document the movements of these catheters within the heart cycle, and to establish whether any patterns existed. We analyzed two-dimensional real time echocardiography cross-sectional images of the human pulmonary artery in 20 patients, plotting the position of the intra-arterial catheter frame-by-frame onto a standardized template. We found that movement of the catheter within the pulmonary artery occurred in a seemingly random pattern. There was no movement pattern to the inferior right of the vessel, an area known to have complex velocity profiles and erroneous velocity measurements. The catheter moved substantially throughout the heart cycle, occasionally quite close to the vessel wall. We observed significant movement of the pulmonary artery catheter throughout the heart cycle, without any predictable pattern. Although we did not specifically investigate the effect of these movements on cardiac output, they imply that intra-arterial Doppler flow measurements from the pulmonary artery may be inaccurate, since a stable catheter position, and hence, a sample volume, cannot be ensured. Further speculation can be made on the implications of these movements in regard to thermodilution cardiac output and safety.

Adult↗

Three-dimensional visualization of velocity profiles in the human main pulmonary artery with magnetic resonance phase-velocity mapping.

Detailed data on blood velocity fields in the normal human main pulmonary artery are an essential platform for discriminating physiologic from pathologic pulmonary flow patterns. Over the years, many studies have revealed quite inconsistent data mainly because of lack of suitable measuring techniques. By using combined cardiac- and respiratory-triggered magnetic resonance phase velocity mapping, very consistent data were obtained in 12 volunteers. In all subjects the location of the highest axial velocities was shifted from the inferior-right toward the superior-left part of the vessel area during the right ventricular contraction, with rapidly decreasing velocities to the inferior right evolving into retrograde flow in the deceleration phase. The mean temporal velocity profile was consistently skewed with a low flow region also toward the inferior-right vessel wall. The magnetic resonance phase shift method used in this study provided remarkably consistent high-quality data about human pulmonary artery velocity fields. This is most likely because of the use of combined cardiac and respiratory triggering.

Adult↗

[Transesophageal echocardiography for registration of hemodynamics. A new tool in anesthesiology].

During the last ten years, transesophageal echocardiography has become an important tool for cardiac monitoring. In other countries it is widely applied, especially in cardiac surgery, but the areas of application are still expanding. Transesophageal echocardiography is a non-invasive technique in contrast to most other methods available for monitoring central haemodynamics. The complication frequency is extremely low. However, correct therapeutic decisions depend on profound experience with the equipment and image interpretation. The scope of transoesophageal echocardiography as a new tool in haemodynamic monitoring is described in this paper together with preliminary results.

Anesthesiology↗

Procedure-related rate of contact of intensive care unit personnel with patient body fluids.

We prospectively recorded the frequency with which ICU personnel came in contact with body fluids in order to provide an empirical basis for the recommendation of relevant protective precautions. ICU personnel completed a questionnaire when performing a range of 29 standardized procedures. The rate of contact with body fluid was: manual ventilation (55%); catheterization of peripheral vein (36%); insertion of central venous catheter (69%); arterial puncture (18%); tracheal intubation (76%); tracheal extubation (87%); suction from mouth, pharynx or trachea (82%); drawing of blood sample (52%); establishing or discontinuing blood transfusion (50%); establishing or discontinuing infusion (20%); changing of wound dressing (52%). We suggest that the contact rates observed should be used in combination with a universal precautions policy, in order to identify procedures that are likely to involve contact with body fluid. By using gloves 95% of contacts to body fluid would have been prevented.

Body Fluids↗

Individual predictability of repeated spinal anaesthesia with plain 0.5% bupivacaine.

To evaluate the individual predictability of spinal anaesthesia, 10 patients (3 women and 7 men) scheduled for control cystoscopy were studied twice within 9 months. Lumbar puncture was performed in the midline at the L2/3 interspace with the patient in the sitting position using plain 0.5% bupivacaine at 37 degrees C. A non-parametric Spearman test showed that, on the basis of the first block, the predictability of the cephalad analgesic spread of the second anaesthesia was high up to 60 min after injection. Thereafter the predictability decreased. The predictability of the motor blockade was generally low. Six patients obtained complete motor blockade twice; the remaining four, once.

Aged↗