New experimental model of sinus and cortical vein thrombosis in pigs for MR imaging studies.

INTRODUCTION: Diagnosis of cerebral sinus vein thrombosis is still a challenge for imaging. MRI and MRA play a major role in sinus imaging. For further development of MR techniques, MR-compatible animal models are required. The aim of this study was to develop an animal model for sinus thrombosis and additional cortical vein thrombosis with a clot of human blood for MR imaging studies. METHODS: A combined surgical and interventional approach was carried out in 13 pigs. After minimal invasive surgical access to the anterior superior sagittal sinus and cortical vein, thrombosis with human blood was induced using an interventional catheter approach. MR imaging was performed prior to and after thrombus induction. RESULTS: Sinus thrombosis was induced in 12 of 13 animals. Three animals suffered acute subdural haemorrhage; one of these animals died during the intervention, and one died after thrombus induction. MR imaging of the thrombosed sinus could easily be performed without significant artefacts in 11 of 13 animals. CONCLUSION: This new model of sinus and cortical vein thrombosis with a clot of human blood allows artefact-free imaging studies on MR.

Animals↗

Impact of ECG gating in contrast-enhanced MR angiography for the assessment of the pulmonary veins and the left atrium anatomy.

PURPOSE: Implementation of ECG gating in contrast-enhanced MR angiography (ceMRA) for improved visualization of the pulmonary veins, the left atrium, and the thoracic vessels. MATERIALS AND METHODS: CeMRA was performed on twelve patients with a history of recurrent atrial fibrillation for the purpose of an intra-individual comparison with and without ECG gating on a 1.5 Tesla MR system (Gyroscan Intera, Philips Medical Systems, Best, NL). Objective image quality parameters such as the signal-to-noise ratio (SNR) of the blood and the contrast-to-noise ratio (CNR) between the blood and myocardium or lung parenchyma were analyzed. The contour sharpness of the pulmonary veins, left atrium, ascending aorta, and pulmonary trunk was also measured. In addition, the artifact level was subjectively assessed by two observers blinded with respect to the sequence parameters. Statistically significant differences (p < 0.05) between the procedures were analyzed using the Wilcoxon test and Pearson Chi-square test. RESULTS: The use of ECG gating in ceMRA significantly reduced artifacts caused by cardiac motion and vessel pulsation. This in turn lead to a significant increase in the contour sharpness of the left atrium and the thoracic vessels. In addition, higher SNR and CNR were found using ECG-gated ceMRA compared to standard ceMRA. CONCLUSION: The use of ECG gating in ceMRA results in artifact-free and sharper delineation of the structures of the heart and thoracic vessels.

Artifacts↗

Inversion prepared coronary MR angiography: direct visualization of coronary blood flow.

PURPOSE: Visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. MATERIALS AND METHODS: Coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: In contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. CONCLUSION: The combination of a free-breathing navigator-gated and cardiac-triggered 3D SSFP sequence with a slice-selective inversion pre-pulse allows for direct and directional visualization of coronary blood flow with the additional benefit of improved contrast between coronary and right ventricular blood pool.

Adult↗

[Heart tumors: magnetic resonance imaging and multislice spiral CT].

Transthoracic echocardiography is usually the initial diagnostic test in patients with a suspected cardiac mass. However, this technique is restricted by its small field of views and insufficient acoustic window in some patients. Magnetic resonance imaging (MRI) and, since its introduction, multislice spiral computed tomography allow for detailed delineation of intra and pericardiac tumors, their extent, and their influence on cardiac function. Primary benign and malignant cardiac tumors have several characteristic features in MR imaging. Assessment of such features may narrow down the differential diagnosis or even allow for reliable diagnosis in selected cases. Many such features can also be assessed using MSCT. This article provides an overview of examination protocols of MRI and CT for cases in which a cardiac mass is suspected and describes the appearance of primary and secondary cardiac masses as well as intracavitary thrombi.

Adult↗

Coronary MR imaging using free-breathing 3D steady-state free precession with radial k-space sampling.

PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. RESULTS: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. CONCLUSION: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.

Adult↗

Quantitative and qualitative assessment of left ventricular volume with ECG-gated multislice spiral CT: value of different image reconstruction algorithms in comparison to MRI.

PURPOSE: To assess the value of different image reconstruction algorithms for assessment of the left ventricular function using retrospectively ECG-gated multislice spiral computed tomography (MSCT) of the heart. MATERIAL AND METHODS: MSCT and cine magnetic resonance (MR) imaging of the heart were performed in 15 patients. For MSCT, standard and multisegmental image reconstruction with improved temporal resolution were used. Standardized multiplanar reformats in the short axis and long axis views were reconstructed from MSCT data. End-systolic (ESV) and end-diastolic volume (EDV), stroke volume (SV), ejection fraction (EF) and myocardial mass (MM) were calculated. Left ventricular wall motion was assessed qualitatively. RESULTS: MSCT was in acceptable agreement with MR imaging for quantification of the ventricular function. According to the Bland-Altman approach the mean differences for the left ventricular volumes (ESV, EDV, SV) ranged from -9.6 ml to 3.1 ml with standard image reconstruction and from -0.6 ml to 1.9 ml utilizing multisegmental image reconstruction with limits of agreement ranging from -26.6 ml to 12.5 ml and -15.6 ml to 15.0 ml, respectively. Applying the multisegmental image reconstruction algorithm, a significantly improved agreement with the MR data was found for EDV, SV and EF. For wall motion analysis, standard image reconstruction showed a significant difference to MR imaging with a correspondence in 83.75% of the 240 assessed segments, while multisegmental image reconstruction agreed with MR imaging in 92.5% of the segments. CONCLUSION: Multisegmental image reconstruction improves the quantitative assessment of left ventricular function when compared to standard image reconstruction. Multisegmental image reconstruction allows qualitative wall motion analysis.

Adult↗

[Technical aspects of MR coronary angiography].

Within the past several years, MR angiography (MRA) has experienced major technological improvements. Whereas the contrast enhanced MRA of non-coronary vessels has become established in routine clinical diagnostics, MR coronary angiography still represents technical challenges to the MR scientists and clinical investigators. To allow diagnostic quality MR coronary angiography, precise and reliable visualization of small tortuous vessels moving at fast speed is necessary. This article reviews the basic principles of MRA with special consideration to MR coronary artery imaging.

Contrast Media↗

Real-time-MR guidance for placement of a self-made fully MR-compatible atrial septal occluder: in vitro test.

PURPOSE: This in vitro study investigated the feasibility to visualize the placement of three different atrial septal occluder systems using real-time MR control. METHODS: The experiments were performed on an interventional 1.5 T high field whole body system. Real-time MR imaging was achieved by radial or spiral k-space filling in conjunction with the sliding window reconstruction technique yielding an imaging speed of 15 frames per second. The CardioSeal, Amplatzer Septal Occluder and a specially designed MR-compatible closure device were tested in a water bath. A punctured plastic wall served as model for the atrial septal defect. RESULTS: The delivery systems of the CardioSeal and Amplatzer Occluder were ferromagnetic and caused substantial artifacts, making the device placement impossible, even if the magnetic forces would have been acceptable. The self-made prototype caused only minor susceptibility artifacts allowing its visualization on the MR images. The MR imaging techniques applied enabled real-time control of the occluder including steering through the artificial septal foramen and visualization of the occluder deployment. CONCLUSION: Real-time MR imaging allows for guidance and placement of an MR-compatible septal occluder in vitro suggesting the feasibility to perform atrial septal occlusion under MR-guidance in vivo as well.

Heart Atria↗

Navigator-gated and real-time motion corrected free-breathing MR Imaging of myocardial late enhancement.

PURPOSE: A new magnetic resonance imaging approach for detection of myocardial late enhancement during free-breathing was developed. METHODS AND RESULTS: For suppression of respiratory motion artifacts, a prospective navigator technology including real-time motion correction and a local navigator restore was implemented. Subject specific inversion times were defined from images with incrementally increased inversion times acquired during a single dynamic scout navigator-gated and real-time motion corrected free-breathing scan. Subsequently, MR-imaging of myocardial late enhancement was performed with navigator-gated and real-time motion corrected adjacent short axis and long axis (two, three and four chamber) views. This alternative approach was investigated in 7 patients with history of myocardial infarction 12 min after i. v. administration of 0.2 mmol/kg body weight gadolinium-DTPA. CONCLUSION: With the presented navigator-gated and real-time motion corrected sequence for MR-imaging of myocardial late enhancement data can be completely acquired during free-breathing. Time constraints of a breath-hold technique are abolished and optimized patient specific inversion time is ensured.

Adult↗

Three-dimensional high-resolution fast spin-echo coronary magnetic resonance angiography.

Due to SNR constraints, current "bright-blood" 3D coronary MRA approaches still suffer from limited spatial resolution when compared to conventional x-ray coronary angiography. Recent 2D fast spin-echo black-blood techniques maximize signal for coronary MRA at no loss in image spatial resolution. This suggests that the extension of black-blood coronary MRA with a 3D imaging technique would allow for a further signal increase, which may be traded for an improved spatial resolution. Therefore, a dual-inversion 3D fast spin-echo imaging sequence and real-time navigator technology were combined for high-resolution free-breathing black-blood coronary MRA. In-plane image resolution below 400 microm was obtained. Magn Reson Med 45:206-211, 2001.

Adult↗

The impact of navigator timing parameters and navigator spatial resolution on 3D coronary magnetic resonance angiography.

The impact of navigator spatial resolution and navigator evaluation time on image quality in free-breathing navigator-gated 3D coronary magnetic resonance angiography (MRA), including real-time motion correction, was investigated in a moving phantom. Objective image quality parameters signal-to-noise ratio (SNR) and vessel sharpness were compared. It was found that for improved mage quality a short navigator evaluation time is of crucial importance. Navigator spatial resolution showed minimal influence on image quality.

Computer Systems↗

Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography.

While 3D thin-slab coronary magnetic resonance angiography (MRA) has traditionally been performed using a Cartesian acquisition scheme, spiral k-space data acquisition offers several potential advantages. However, these strategies have not been directly compared in the same subjects using similar methodologies. Thus, in the present study a comparison was made between 3D coronary MRA using Cartesian segmented k-space gradient-echo and spiral k-space data acquisition schemes. In both approaches the same spatial resolution was used and data were acquired during free breathing using navigator gating and prospective slice tracking. Magnetization preparation (T(2) preparation and fat suppression) was applied to increase the contrast. For spiral imaging two different examinations were performed, using one or two spiral interleaves, during each R-R interval. Spiral acquisitions were found to be superior to the Cartesian scheme with respect to the signal-to-noise ratio (SNR) and contrast-to-noise-ratio (CNR) (both P < 0.001) and image quality. The single spiral per R-R interval acquisition had the same total scan duration as the Cartesian acquisition, but the single spiral had the best image quality and a 2.6-fold increase in SNR. The double-interleaf spiral approach showed a 50% reduction in scanning time, a 1.8-fold increase in SNR, and similar image quality when compared to the standard Cartesian approach. Spiral 3D coronary MRA appears to be preferable to the Cartesian scheme. The increase in SNR may be "traded" for either shorter scanning times using multiple consecutive spiral interleaves, or for enhanced spatial resolution.

Adult↗

3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition.

Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.

Adult↗

MR-venography using high resolution True-FISP.

A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by x-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-venography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis.

Adolescent↗

Improved in-stent magnetic resonance angiography with high flip angle excitation.

RATIONALE AND OBJECTIVES: To optimize the intraluminal signal intensity of a nitinol stent by performing contrast-enhanced three-dimensional magnetic resonance angiography (CE-MRA) with varying flip angles (FAs). METHODS: Contrast-enhanced magnetic resonance angiography at 1.5 T and FAs of 30 degrees, 100 degrees, and 150 degrees was performed on five sheep with 10 iliac nitinol stents (Memotherm-FLEXX). Maximum-intensity projections (MIPs) and composite images of MIPs were performed and compared. RESULTS: Reconstructed MIPs at an FA of 150 degrees showed a slightly disturbed lumen visibility inside the stent accompanied by low-grade lumen visibility outside the stent and vice versa for an FA of 30 degrees. Composite images of a 30 degrees MIP added to a 150 degrees MIP resulted in improved image quality compared with the standard MIP of a single FA. CONCLUSIONS: Signal loss due to radiofrequency shielding inside nitinol stents imaged by CE-MRA can be reduced by applying high FAs. Composite MIP images allow simultaneous visualization of the lumen inside as well as outside the stent.

Alloys↗

Diffusion-weighted MR imaging for differentiation of benign fracture edema and tumor infiltration of the vertebral body.

OBJECTIVE: The aim of this study was to investigate diffusion-weighted MR imaging for differentiation of benign fracture edema and tumor infiltration with and without accompanying fracture. SUBJECTS AND METHODS: In 10 volunteers, diffusion-weighted spin-echo, fat-suppressed spin-echo, and stimulated-echo sequences were optimized on a clinical 1.5-T scanner. In 34 patients, MR imaging with and without diffusion-sensitizing gradients (b = 598 sec/mm(2) in spin-echo and fat-suppressed spin-echo, b = 360 sec/mm(2) in stimulated-echo) was performed. Thirty-five lesions were analyzed, with 18 caused by acute (< or =10 days old) osteoporotic or traumatic fractures and 17 caused by untreated malignant vertebral infiltration including nine fractures. Signal attenuation in diffusion-weighted images and contrast-to-noise ratio were calculated. The diffusion-weighted images were analyzed by two radiologists. RESULTS: Images from three of 34 patients were excluded because of motion artifact. In osteoporotic and traumatic fractures, a strong signal attenuation of bone marrow edema was seen. In contrast to this, malignant-tumor infiltration caused only minor signal attenuation (p < 0.05), independent of accompanying pathologic fracture. All sequences showed identical changes of signal intensities. In four patients, initial diagnosis was changed by the findings in the diffusion-weighted images. CONCLUSION: Diffusion-weighted spin-echo, fat-suppressed spin-echo, and stimulated-echo sequences are equally suitable for imaging of the spine. Calculation of signal attenuation and observation of signal characteristics allowed differentiation of benign fracture edema and tumor infiltration and provided excellent distinction between benign and malignant vertebral fractures in our series.

Adult↗

Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging.

BACKGROUND: Conventional x-ray angiography frequently underestimates the true burden of atherosclerosis. Although intravascular ultrasound allows for imaging of coronary plaque, this invasive technique is inappropriate for screening or serial examinations. We therefore sought to develop a noninvasive free-breathing MR technique for coronary vessel wall imaging. We hypothesized that such an approach would allow for in vivo imaging of coronary atherosclerosis. METHODS AND RESULTS: Ten subjects, including 5 healthy adult volunteers (aged 35+/-17 years, range 19 to 56 years) and 5 patients (aged 60+/-4 years, range 56 to 66 years) with x-ray-confirmed coronary artery disease (CAD), were studied with a T2-weighted, dual-inversion, fast spin-echo MR sequence. Multiple adjacent 5-mm cross-sectional images of the proximal right coronary artery were obtained with an in-plane resolution of 0.5x1.0 mm. A right hemidiaphragmatic navigator was used to facilitate free-breathing MR acquisition. Coronary vessel wall images were readily acquired in all subjects. Both coronary vessel wall thickness (1.5+/-0.2 versus 1.0+/-0.2 mm) and wall area (21.2+/-3.1 versus 13.7+/-4.2 mm(2)) were greater in patients with CAD (both P:<0.02 versus healthy adults). CONCLUSIONS: In vivo free-breathing coronary vessel wall and plaque imaging with MR has been successfully implemented in humans. Coronary wall thickness and wall area were significantly greater in patients with angiographic CAD. The presented technique may have potential applications in patients with known or suspected atherosclerotic CAD or for serial evaluation after pharmacological intervention.

Adipose Tissue↗