PubMed Health⌕ Search

Biomedical subjects

E Thérasse

Publications and source records attributed to E Thérasse.

13 recordsLinked to original sources

Percutaneous revascularization of the renal arteries: predictors of outcome.

PURPOSE: To identify predictors of clinical outcome after percutaneous revascularization of the renal arteries. MATERIALS AND METHODS: In 63 patients, the therapeutic response was retrospectively assessed after percutaneous revascularization of the renal arteries indicated for hypertension (41.3%), renal failure (4.8%), or both (53.9%). All patients underwent percutaneous transluminal renal angioplasty, complemented by stent insertion in 30 patients. The authors analyzed the role of clinical and imaging factors, including scintigraphy, Doppler sonography, and angiography for predicting clinical success. RESULTS: In the hypertensive population, there were three cures (5.6%), 26 improvements (48.1%), and 25 failures (46.3%). Among patients with renal insufficiency, 12 were improved (37.5%), 11 were stabilized (34.4%), and nine deteriorated (28.1%). Predictors of favorable outcome for hypertension were shorter duration of hypertension, higher diastolic blood pressure, fibromuscular dysplasia, abnormal Doppler study, higher percentage of angiographic stenosis, and lower grade of aortic atheromatous disease. Predictors of favorable outcome for renal failure were nondiabetic status, abnormal Doppler study, and higher percentage of angiographic stenosis. Abnormal Doppler and scintigraphic examinations predicted successful treatment of hypertension in 60% and 53.8% of cases, respectively, and renal insufficiency in 85% and 60% of cases, respectively. CONCLUSION: Clinical and angiographic variables were the best predictors of therapeutic success for hypertension. Doppler sonography was useful in patients with renal failure.

Angiography↗

Digital subtraction angiography of the abdominal aorta and lower extremities: carbon dioxide versus iodinated contrast material.

PURPOSE: To compare the diagnostic value of carbon dioxide to that of iodinated contrast material for digital subtraction angiography of the abdominal aorta and lower extremities. MATERIALS AND METHODS: Thirty-five patients underwent comparative CO2 and iodinated contrast material arteriography of the abdominal aorta and lower extremities. For each contrast study, three independent observers evaluated the degree of opacification and percentage of stenosis of each vessel, the degree of certainty of their observations, and the overall quality of the study. Data of CO2 and iodinated studies were compared using analysis of variance for repeated measures. Interobserver and intertechnique agreements were estimated with Cohen's kappa and intraclass correlation coefficient. RESULTS: Iodine-based vascular opacification was superior to that with CO2 in the central and distal arteries (P = .02). The degree of certainty and overall quality score were higher for iodine than for CO2-based contrast studies (P = .00001). The interobserver agreement for categorizing stenoses was higher for iodine as compared to CO2-based angiography. No significant difference was observed between the mean stenosis values obtained with CO2 and iodine-based angiography in any segment. Intraclass correlation coefficient demonstrated a high degree of convergence of the two techniques for assessing the percentage of stenosis. CONCLUSION: CO2 can be used as an alternative to iodinated contrast material for obtaining arteriograms of the abdominal aorta and lower extremities for investigating atherosclerotic disease.

Aged↗

Comparison of early and delayed scintigraphy with 99mTc-apcitide and correlation with contrast-enhanced venography in detection of acute deep vein thrombosis.

UNLABELLED: Preliminary studies with 99mTc-apcitide (99mTc-P280), a synthetic peptide that binds to glycoprotein IIb/IIIa receptors expressed on activated platelets, have shown promising results in the detection of acute deep vein thrombosis (ADVT). The purpose of this study was to compare the diagnostic value of early and delayed imaging with 99mTc-apcitide in patients with suspected ADVT, using contrast-enhanced venography as the gold standard. METHODS: Thirty-nine patients (17 women, 22 men; mean age 59 y) with signs or symptoms suggestive of ADVT (within 10 d of onset) and scheduled for contrast-enhanced venography were prospectively studied. The patients were injected with approximately 740 MBq (20 mCi) 99mTc-apcitide within 36 h of contrast-enhanced venography. Both anterior and posterior planar images (8-10 min/view) of the lower extremities using a dual-head gamma camera were obtained at 10, 60 and 120 min after the injection of 99mTc-apcitide. The three sets of images initially were interpreted randomly and separately by three experienced observers unaware of the clinical history, the site of ADVT and results of contrast-enhanced venography. All images from the three sets for a given patient were then analyzed together during a second session. Conventional contrast-enhanced venography was performed on 31 patients before 99mTc-apcitide scintigraphy and in the remaining 8 patients after 99mTc-apcitide scintigraphy. 99mTc-apcitide findings were considered positive forADVT when a focus of increased uptake was found to correspond to the location of a deep vein. Disagreements were resolved by consensus. RESULTS: Twenty-two patients had ADVT observed on contrast-enhanced venography, whereas 17 had normal findings. Six cases of ADVT were infrapopliteal. One patient did not complete the third set of images with 99mTc-apcitide. The sensitivity of 99mTc-apcitide in detecting ADVT was 63.6% (14/22), 68.2% (15/22), 76.2% (16/21) and 86.4% (19/22) for images obtained at 10, 60 and 120 min and for the three sets analyzed together, respectively. The specificity was 82.4% (14/17), 76.5% (13/17), 88.2% (15/17) and 88.2% (15/17) for images obtained at 10, 60 and 120 min and for the three sets of images together, respectively. CONCLUSION: Although the set of 99mTc-apcitide images obtained 120 min after injection showed good overall diagnostic accuracy, the combination of at least two sets of images provided the highest accuracy in detecting ADVT.

Acute Disease↗

Detection of renal artery stenosis with Doppler sonography before and after administration of captopril: value of early systolic rise.

OBJECTIVE: The goal of this study was to assess the value of quantitative and qualitative analysis of the early systolic rise on Doppler waveforms obtained before and after administration of captopril in patients suspected of having renal artery stenosis. SUBJECTS AND METHODS: Seventy-one hypertensive patients (135 kidneys) were studied with transrenal Doppler sonography. Ninety-six kidneys were studied again after administration of captopril. All patients also underwent renal angiography. All Doppler studies were independently reviewed by two observers. Specific criteria for Doppler waveform patterns that were applied in the detection of renal artery stenosis included acceleration, acceleration time of early systolic rise, differential velocity of systolic rise, and resistive index. These criteria were then correlated with angiography, and receiver operating characteristic curves were generated. RESULTS: On the basis of waveform pattern recognition. Doppler sonograms obtained before administration of captopril had a sensitivity of 81% and a specificity of 98% for the detection of renal artery stenosis greater than or equal to 50%. Sensitivity of Doppler sonography obtained after administration of captopril was 100%, and specificity was 100%. For renal artery stenosis greater than or equal to 70%, sensitivity was 94% and specificity was 89% before administration of captopril. The area under the receiver operating characteristic curve for the acceleration criterion was significantly larger after administration of captopril (p = .009) for the detection of renal artery stenosis greater than or equal to 50%. After captopril administration, an acceleration threshold value of 440 cm/sec2 for early systolic rise was associated with a sensitivity of 100% and a specificity of 94% for the detection of renal artery stenosis greater than or equal to 50%. CONCLUSION: Doppler sonography of the renal arteries performed before administration of captopril appears to be an excellent screening tool in the detection of severe stenosis (> or = 70%). Administration of captopril improves the detection of renal artery stenosis greater than or equal to 50% with Doppler sonography when observers use both morphologic and quantitative criteria.

Antihypertensive Agents↗

Left hepaticogastrostomy for biliary obstruction: long-term results.

PURPOSE: To evaluate the long-term results of peripheral biliary diversion by means of anastomoses of the left lobe of the liver to the stomach. MATERIALS AND METHODS: Transhepatic perforation of the left lobe of the liver into the lesser curvature of the stomach was performed in 35 patients with a presumed diagnosis of malignant obstructive jaundice. Jaundice was found to be caused by a malignant stricture in 32 patients and a benign stricture in three. Perforation was performed under fluoroscopic, endoscopic, and laparoscopic guidance in 33 patients and without laparoscopy in the other two. The hepaticogastric anastomosis was secured with a gastrostomy tube; patency of the tract was maintained with placement of a metallic stent. Kaplan-Meier analysis was used to evaluate survival, anastomosis patency rate, and jaundice recurrence. RESULTS: Technical success was achieved in all patients. Two (6%) patients had anastomotic obstruction. The actuarial survival rate was 91%, 80%, 59%, and 26% at 1, 3, 6, and 12 months. The mean patency was 234 days +/- 252. The jaundice-free rate among surviving patients was 100%, 96%, 93%, and 80% at 1, 3, 6, and 12 months. The reintervention rate was 14%. Late cholangitis occurred in seven (20%) patients. CONCLUSION: This peripheral diversion procedure appears to be safe and shows good long-term patency.

Adult↗

Percutaneous stent placement for treatment of stenosis of a portacaval H-graft shunt.

Surgical treatment of an occluded or stenotic portacaval shunt carries a high risk of mortality, but the rate of restenosis after transluminal angioplasty is also high. The authors report high-grade stricture of a portacaval H-graft shunt in a 51-year-old man, who presented with hematemesis and melena. The patient was treated with concomitant balloon angioplasty and placement of a metallic stent through a percutaneous venous approach. The procedure was tolerated well by the patient, and stenosis had not recurred at follow-up 1 year later.

Angioplasty, Balloon↗

Malignant biliary obstruction: preliminary results of palliative treatment with hepaticogastrostomy under fluoroscopic, endoscopic, and laparoscopic guidance.

PURPOSE: To report a technique of peripheral biliary decompression by means of anastomosis of a bile duct in segment II of the liver to the lesser curvature of the stomach. MATERIALS AND METHODS: Seven patients with unresectable biliary neoplasm were treated. After transhepatic catheterization of a segment II bile duct, the left lobe of the liver and the lesser curvature of the stomach were perforated under fluoroscopic and laparoscopic guidance. Anastomosis between the biliary tree and the stomach was maintained with a gastrostomy tube placed across the tract. After 2 weeks, the tube was removed and patency of the tract was preserved with a metallic stent. RESULTS: Three patients died, at 3, 6, and 9 months, respectively, without reocclusion; the other four were alive at 5 months without jaundice. One patient had an episode of cholangitis, which was resolved with antibiotic therapy. CONCLUSION: This method yields a good patency rate with few problems. Further investigation is required to evaluate long-term patency and the necessity of laparoscopic guidance.

Aged↗

[Percutaneous metallic biliary prosthesis].

Two types of metallic endoprostheses may be placed via a transhepatic approach: 1) self expandable stents which open by themselves as soon as they are released from the carrier system, 2) balloon expandable stents which need to be dilated by a balloon catheter at the time of deployment. Gianturco and Wallstent endoprostheses belong to the first group and are most often used. The fenestrated wall of metallic endoprostheses preserves the patency of bile ducts joining the stented segment, which is a major advantage for hilar and intra-hepatic stenosis. Their design allows the endoprostheses to be incorporated into the bile duct wall, minimising biliary encrustation and leaving a wider internal lumen as compared to plastic stents. On the other hand, tumor ingrowth in the stented segment is possible and parietal incorporation makes the stent nonretrievable after a few weeks. A favorable indication is therefore extrinsic compression, especially in hilar and intra-hepatic segments. Whatever the indications, metallic stenting has an advantage in the treatment of biliary stenosis, either benign or malignant, owing to less traumatic positioning while their patency rate remains high.

Adenocarcinoma↗

Comparison of streptokinase and urokinase in local thrombolysis of peripheral arterial occlusions for lower limb salvage.

PURPOSE: To compare the efficacy and safety of streptokinase (SK) and urokinase (UK) in the treatment of local thrombolysis. PATIENTS AND METHODS: Over a 24-month period, 40 patients with 45 lower limb arterial occlusions of less than 45 days duration underwent intraarterial fibrinolysis. Twenty occlusions were treated with recombinant UK and tissue culture-derived UK, and 25 occlusions were treated with SK. The study was retrospective, but the two groups were very homogeneous in terms of vascular surgical history, medical risk factors, and occlusion characteristics. RESULTS: Complete lysis (95% or more) was achieved in 84% of SK infusions and 89% of UK infusions. Endoluminal and surgical interventions as well as clinical outcomes of SK and UK treatment were comparable. However, infusion time was significantly longer for SK treatment: 28.5 hours versus 19.1 hours for UK treatment (P = .035). Complication rates were not statistically significantly different. Average length of stay in the intensive care unit was identical (2.2 days) for both groups, and the difference in hospital stay was not statistically significant (7.7 days for SK vs 8.7 days for UK). CONCLUSION: At the concentrations and doses used, the efficacy and safety of SK and UK were comparable, despite longer SK infusion time.

Arterial Occlusive Diseases↗