PubMed Health⌕ Search

Biomedical subjects

E Thein

Publications and source records attributed to E Thein.

16 recordsLinked to original sources

Direct assessment and distribution of regional portal blood flow in the pig by means of fluorescent microspheres.

Measurement of regional organ blood flow by means of fluorescent microspheres (FM) is an accepted method. However, determination of regional portal blood flow (RPBF) cannot be performed by microspheres owing to the entrapment of the spheres in the upstream capillary bed of the splanchnic organs. We hypothesized that an adequate experimental setting would enable us to measure RPBF by means of FM and to analyze its distribution within the pig liver. A mixing chamber for the injection of FM was developed, and its capability to distribute FM homogeneously in the blood was evaluated in vitro. The chamber was implanted into the portal vein of six anesthetized pigs (23.5 +/- 2.9 kg body wt). Three consecutive, simultaneous injections of FM of two different colors into the chamber were performed. Reference portal blood samples were collected by means of a Harvard pump. At the end of the experiment, the liver was explanted and fixed in formalin before dissection. FM were isolated from the tissue samples by an automated process, and fluorescence intensity was determined. Comparison of 5,458 single RPBF values, determined by simultaneously injected FM, revealed good agreement (bias 2.5%, precision 12.7%) and high correlation (r = 0.97, r2 = 0,95, slope = 1.04, intercept = 0.05). Median RPBF was 1.07 +/- 0.78 ml x min(-1) x g(-1). Allocation of the blood flow values to the anatomic regions of the liver revealed a significantly higher RPBF (P = 0.01) in the liver tissue located close to the diaphragm compared with the rest of the organ and a significantly lower RPBF (P = 0.01) in the left liver lobe compared with the median and right lobes. The results show that the model presented makes it possible to measure RPBF by means of FM reliably and that RPBF is distributed heterogeneously in the porcine liver.

Animals↗

The influence of periarterial papaverine application on intraoperative renal function and blood flow during laparoscopic donor nephrectomy in a pig model.

BACKGROUND: The transplantation of live donor kidneys harvested laparoscopically is associated with a higher incidence of delayed graft function than the transplantation of grafts harvested via the open technique. The delay is believed to be due to a decrease in renal blood flow during laparoscopic donor nephrectomy (LDN). The aim of this study was to evaluate whether renal function and blood perfusion can be enhanced by the periarterial application of papaverine during LDN. METHODS: Renal function and blood flow were studied in a porcine model that included a total of 24 pigs (20-30 kg). In 12 of the pigs, urine output and creatinine clearance were determined as measures of renal function. In the other 12 pigs, renal blood flow was determined using fluorescent-labeled microspheres. In each group, the pigs were randomized into two subgroups, one with and one without a perivascular injection of 50 mg papaverine. RESULTS: As compared to the controls, the animals receiving papaverine had a significantly higher urine output (3.1 +/- 1.6 vs 0.9 +/- 0.45 ml/h/kg; p = 0.02), superior creatinine clearance (2.22 +/- 0.5 vs 0.95 +/- 0.1 ml/min/kg; p = 0.038), and enhanced renal blood flow (4.9 +/- 2.2 vs 2.1 +/- 0.8 ml/min/g; p = 0.008). CONCLUSIONS: When applied to the tissue surrounding the renal artery, papaverine substantially improves renal function and blood flow during laparoscopic live kidney donation. Whether graft optimization during kidney procurement also translates into improved posttransplantation function remains to be established.

Animals↗

Validity of fluorescent microspheres method for bone blood flow measurement during intentional arterial hypotension.

In this study, we compared bone blood flow values obtained by simultaneously injected fluorescent (FM) and radiolabeled microspheres (RM) at stepwise reduced arterial blood pressure. Ten anesthetized female New Zealand White rabbits received simultaneous left ventricular injections of FM and RM at 90, 70, and 50 mmHg mean arterial blood pressure (MAP). After the experiments, both kidneys and long bones of all four limbs were removed and dissected in a standardized manner. Radioactivity (corrected for decay, background, and spillover) and fluorescence were determined, and blood flow values were calculated. Relative blood flow values estimated for each bone sample by RM and FM were significantly correlated (r = 0.98, slope = 0.99, and intercept = 0.04 for 90 mmHg; r = 0.98, slope = 0.94, and intercept = 0.09 for 70 mmHg; r = 0.98, slope = 0.96, and intercept = 0.07 for 50 mmHg). Blood flow values (ml x min-1 x 100 g-1) of right and left bone samples determined at the different arterial blood pressures were identical. During moderate hypotension (70 mmHg MAP), blood flow in all bone samples remained unchanged compared with 90 mmHg MAP, whereas a significant decrease of bone blood flow was observed at severe hypotension (50 mmHg MAP). Our results demonstrate that the FM technique is valid for measuring bone blood flow. Differences in bone blood flow during altered hemodynamic conditions can be detected reliably. In addition, changes in bone blood flow during hypotension indicate that vasomotor control mechanisms, as well as cardiac output, play a role in setting bone blood flow.

Algorithms↗

Evaluation of a system for the perfusion of isolated, rodent organs.

Perfusion of isolated organs is a common experimental approach. However, the surfaces of the perfusion system might alter the components of the blood and thereby negatively affect organ function. The aim of this study was to minimize the influence of the perfusion system on the blood components and to evaluate the system. Pressure and flow in the perfusion system consisting of a roller-pump, reservoir, oxygenator, hemo-filter and bubble-trap with a total tubing length of 4.5 m are controlled by a computer software (DASYLAB, Datalog, Moenchengladbach, Germany) via a transducer connected to the system. The organ to be perfused is positioned under a microscope (Orthoplan, Leica, Bensheim, Germany), allowing the investigation of microcirculatory parameters. The images raised are recorded on video tapes. To evaluate the system it was perfused with human blood (Hct 28 to 30%) for 90 min. Heparin (n = 6) or citrate (n = 6) served as anti-coagulants. The disappearance of cells from the blood was determined at time points 0, 1, 5, 10, 15, 20, 30, 45, 60, 75 and 90 min by means of a cell counter (AC T8, Coulter Beckmann, Krefeld, Germany). Cell activation was assessed by analysis of the expression of L- and P-selectin and CD11b. The activation of the complement system was examined by measuring the serum levels of the complement factors C3c and C4. There was no significant loss or activation of the blood cells at any of the above given time points. The serum levels of the complement factors remained within the physiological range and showed no changes throughout the whole experiments. Thus, the perfusion system does not have a negative influence on the blood and its individual components, and is therefore a reliable tool for perfusion experiments.

Acute Disease↗

Diaspirin crosslinked hemoglobin enables extreme hemodilution beyond the critical hematocrit.

BACKGROUND: Normovolemic hemodilution is an effective strategy to limit perioperative homologous blood transfusions. The reduction of hematocrit related to hemodilution results in reduced arterial oxygen content, which initially is compensated for by an increase in cardiac output and oxygen extraction ratio. To increase the efficacy of hemodilution, a low hematocrit should be aimed for; however, this implies the risk of myocardial ischemia and tissue hypoxia. OBJECTIVE: To assess whether hemodilution can be extended to lower hematocrit values by the use of a hemoglobin-based artificial oxygen carrier solution. DESIGN: Prospective, randomized, controlled. SETTING: Animal laboratory of a university hospital. SUBJECTS: Twelve anesthetized, mechanically ventilated pigs. INTERVENTIONS: Isovolemic hemodilution was performed with either 10% diaspirin crosslinked hemoglobin (DCLHb Baxter Healthcare, Boulder, CO; n = 6) or 8% human albumin solution (HSA, oncotically matched to DCLHb, Baxter Healthcare; n = 6) to a hematocrit of 15%, 8%, 4%, 2%, and 1%. MEASUREMENTS AND MAIN RESULTS: In both groups, measurements were performed at baseline at the previously mentioned preset hematocrit values and at the onset of myocardial ischemia characterized by critical hematocrit (significant ST-segment depression >0.1 mV and/or arrhythmia). To determine peripheral tissue oxygenation and myocardial perfusion and function, the following variables were evaluated: total body oxygen transport variables, tissue oxygen partial pressure (tPo2, MDO-Electrode, Eschweiler Kiel, Germany) on the surface of the skeletal muscle, coronary perfusion pressure, left ventricular (LV) end-diastolic pressure, global and regional myocardial contractility (maximal change in pressure over time, LV segmental shortening, microsonometry method), LV myocardial blood flow (fluorescent microsphere technique), LV oxygen delivery, and the ratio between LV subendocardial and subepicardial myocardial perfusion. In the HSA group, critical hematocrit was found at 6.1 (1.8)% (hemoglobin, 2 g x dL(-1)), whereas all DCLHb-treated animals survived hemodilution until hematocrit 1.2 (0.2)% (hemoglobin, 4.7 g x dL(-1)) was achieved without signs of hemodynamic instability. Although arterial oxygen content was higher in the DCLHb group at 1.2% hematocrit than in the HSA group at critical hematocrit (i.e., hematocrit, 6.1%; hemoglobin, 2 g.dL-1) neither oxygen delivery and oxygen uptake nor median tPo2 and hypoxic tPo2 values on the skeletal muscle were different between groups. In contrast, subendocardial ischemia was absent in DCLHb-diluted animals until 1.2% hematocrit was achieved. This was attributable to a higher coronary perfusion pressure (65 (22) mm Hg vs. 19 (8) mm Hg; p <.05), higher subendocardial perfusion (4.1 (2.6) mL.min-1.g-1 vs. 1.2 (0.4) mL x min(-1) x g(-1)), and subendocardial oxygen delivery (5.7 (2) mL x min(-1) x g(-1), p <.05) in DCLHb-diluted animals, resulting in superior myocardial contractility reflected by maximal change in pressure over time (3829 (1914) vs. 1678 (730); p <.05) and higher regional myocardial contractility (11 (8)% vs. 6 (2)%; p <.05). An increased LV end-diastolic pressure reflected LV myocardial pump failure in HSA-diluted animals but was unchanged in DCLHb-diluted animals. In the DCLHb group, systemic vascular resistance index remained at baseline values throughout the protocol, whereas coronary vascular resistance decreased. In contrast, both variables decreased in HSA-diluted animals. CONCLUSION: DCLHb as a diluent allowed for hemodilution beyond the hematocrit value, determined "critical" after hemodilution with HSA (6.1% (1.8)%). Even at 1.2% hematocrit (hemoglobin, 4.7 g x dL(-1)) myocardial perfusion and function were maintained, although at the expense of peripheral tissue oxygenation. This discrepancy in regional oxygenation might be caused by a redistribution of blood flow favoring the heart, which is related to a disproportionate decrease of coronary vascular resistance index during hemodilution with DCLHb.

Animals↗

Automation of the use of fluorescent microspheres for the determination of blood flow.

Fluorescent-labeled microspheres (FM) are a new tool for the determination of organ blood flow. However, the FM-method is labor intensive, because of the necessity to recover the microspheres from the tissue samples. The aim of this study was to automate the FM-method. A Zymate-Robotic System (Zymark, Idstein, Germany) was modified to handle a novel filtration device. The robot is surrounded by 12 different stations which are necessary to process the samples. It performs the sequential steps which are needed to recover the microspheres from the samples. The dyes are finally released from the FM with a solvent and their fluorescent intensity is measured online using a spectrophotometer (Perkin Elmer, Uberlingen, Germany). The robotic system is able to recover the FM through digestion and filtration of the tissue samples using the new filter, to dissolve the FM and to release the dyes so that their fluorescent intensities can be measured for the calculation of organ blood flow.

Animals↗

[A new experimental model for repetitive osseous blood supply measurement].

The aim of this study was to establish a novel model permitting repetitive analysis of osseous perfusion over a period of 33 days using the fluorescent microsphere technique. After implantation of two port systems into the right and left carotid artery in New Zealand rabbits (n = 3), fluorescent microspheres were injected into the left ventricle, while blood samples for reference probes were taken from the descending aorta. Using seven different fluorescently labeled microspheres, injections were repeatedly performed starting 3 days after implantation (t = 0) at days 1, 3, 5, 12, 19, 26, and 33. Osseous blood flow was semiquantitatively analyzed by counting the number of trapped microspheres within the bone sections performed through the distal femur condyle (n = 8) using a fluorescence microscope. Over the entire observation period of 33 days, intraindividual variance in the number of trapped microspheres was low while there were marked interindividual differences between animals. The mean osseous perfusion in the three animals evaluated so far remained constant over the observation period of 33 days. The present model is the first to allow repetitive analysis of osseous perfusion over an observation period of 33 days. Using this model, the role of regional osseous perfusion can be studied under conditions such as impaired bone healing following radiotherapy- and/or chemotherapy, implantation of biomaterials, and transplantation of bone.

Animals↗

Changes in serum osmolarity influence the function of outer hair cells.

Fast motility of outer hair cells (OHC) is thought to be based on a hydromechanic principle. In vitro, the function of OHCs can be disturbed by a change in the osmolarity of the culture medium. Whether changes in the serum osmolarity in vivo can also interfere with OHC motility has not been investigated as yet. Serum osmolarity of New Zealand White rabbits (n = 18) was elevated by a continuous infusion of glucose 40%, decreased by an infusion of aqua dest, or kept constant by an infusion of saline. OHC function was monitored using distortion products of otoacoustic emissions (DPOAE). Input output curves were established between 2 and 5 kHz (geometric mean of f2) with primaries of levels between 35 and 55 dB SPL. Cochlear perfusion was measured using a fluorescence microsphere method. Elevation of the serum osmolarity from 306 +/- 17 mosm/l to 365 +/- 23 induced a decrease of DPOAE between 3 and 12 dB SPL. Cochlear blood flow increased from 0.11 +/- 0.09 to 0.15 +/- 0.10 ml/min/g. When decreasing the serum osmolarity from 303 +/- 9 to 281 +/- 8 mosm/l, only slight changes of the DPOAE could be verified. As in the control group, cochlear perfusion was almost unchanged. In the control group, neither serum osmolarity nor DPOAE changed. Comparable to findings in vitro, increasing the serum osmolarity can lead to a disturbance of OHC function. In patients suffering from sudden hearing loss. dehydration due to physical or mental stress is often observed. This new and promising pathophysiological concept needs further clinical evaluation.

Acoustic Stimulation↗

A new sample-processing unit for the fluorescent microsphere method.

The use of fluorescent-labeled microspheres (FM) for measurement of regional blood flow is an attractive alternative to the use of radioactive-labeled microspheres. In the FM method the FM have to be completely recovered from the tissue samples in a time- and labor-intensive process. For this reason, a considerable loss of FM is possible. The aim of this study was to develop a filtration device that allows the tissue sample to remain in a single container throughout the procedure to make the process easier and to avoid the loss of FM. The core of the sample-processing unit (SPU) is a single-tube filtration device with a polyamide wire mesh. The protocol for processing tissue from different organs (heart, kidney, liver, spleen, intestine, muscle, bone, lung, brain) was modified and thus shortened significantly. Furthermore, the SPU allows direct filtration of the blood reference sample without previous digestion. Different experiments showed that the SPU in combination with the new protocol excludes the loss of 15-micrometers FM. The modifications of the whole procedure render it faster and highly standardized.

Animals↗

Determination of regional bone blood flow by means of fluorescent microspheres using an automated sample-processing procedure.

The determination of regional blood flow utilizing fluorescent microspheres (FMs) is an established method for numerous organs. Recent progress, in particular the automation of sample processing, has further improved this method. However, the FM method (reference sample technique), which allows repetitive measurement of regional organ blood flow, has so far not been used for the determination of blood flow in bone. The aim of the present study was to establish FM for the quantification of regional bone blood flow (RBBF). Female, anesthetized New Zealand rabbits (n = 6) received left ventricular injections of different amounts of FM at six subsequent time points. In order to examine the precision of RBBF determination, two different FM species were injected simultaneously at the sixth injection. At the end of the experiments the femoral and tibial condyles of each hind limb were removed and the fluorescence intensity in the tissue samples was measured by an automated procedure. In an in vitro study we have shown that acid digestion of the crystalline matrix has no effect on the fluorescence characteristics of FM. The determination of the number of spheres per tissue sample revealed that depending on the tissue sample size up to 3 x 10(6) spheres/injection were necessary to obtain about 400 microspheres in the individual bone samples. RBBF values of the tibial and femoral condyles did not differ at various injection intervals. The tibial blood flow values varied between 6.6 +/- 1.1 and 8.5 +/- 1.4 ml/min/100 g and were significantly higher than those of the femur (4.3 +/- 1.1 to 6.0 +/- 1.8 ml/min/100 g). The bone blood flow values obtained by simultaneous injection of two FM species correlated significantly (r = 0.96, slope = 1.06, intercept = 0.05), the mean difference was 0.39 +/- 1.11 ml/min/100 g. Our data demonstrate that the measurement of RBBF by means of FM allows a valid determination of RBBF.

Animals↗