Costs of implementing a tuberculosis control plan: a complete education module that uses a train-the-trainer concept.

BACKGROUND: Tuberculosis once was thought to be nearly eradicated, but there was a 14% increase in cases of tuberculosis between 1985 and 1993, although decreases were observed in both 1994 and 1995. To reduce spread of this disease, health care workers must be familiar with tuberculosis, its signs, symptoms, and modes of transmission. In October 1994 the Centers for Disease Control and Prevention issued "Guidelines for Preventing the Transmission of Mycobacterium tuberculosis in Health Care Facilities." The combination of persistently high tuberculosis case rates, the development of multidrug-resistant tuberculosis, the new Centers for Disease Control and Prevention recommendations, and Occupational Safety and Health Administration enforcement has mandated large-scale training in health care facilities. METHODS: A tuberculosis control plan was developed and the train-the-trainer concept was selected after review of the hospital's tuberculosis risk assessment, staff members requiring training, and available teaching staff. The training program that was developed included tuberculosis pathology and transmission, national and local epidemiology, placement and evaluation of skin tests, and an algorithm to assist in determining when isolation is indicated. RESULTS: One hundred forty-six trainers were trained in 4 days. During the next quarter, 66% (1989/3000) of staff members requiring instruction were trained. The total cost involved in development and training was approximately $26,000 and involved 1600 person-hours. CONCLUSION: Tuberculosis training should be directed toward high-risk areas, including intensive care units, emergency departments, and acute medicine wards. Large-scale training is time-consuming and expensive. Evaluation remains difficult. To facilitate compliance, pretest and posttest results should be provided, linked to Occupational Safety and Health Administration compliance and quality indicators for the hospital.

Allied Health Personnel↗

A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients.

STUDY OBJECTIVE: To determine the safety and cost-effectiveness of mechanical ventilation with an extended-use hygroscopic condenser humidifier (Duration; Nellcor Puritan-Bennett; Eden Prairie, Minn) compared with mechanical ventilation with heated-water humidification. DESIGN: Prospective randomized clinical trial. SETTING: Medical and surgical ICUs of Barnes-Jewish Hospital, St. Louis, a university-affiliated teaching hospital. PATIENTS: Three hundred ten consecutive qualified patients undergoing mechanical ventilation. INTERVENTIONS: Patients requiring mechanical ventilation were randomly assigned to receive humidification with either an extended-use hygroscopic condenser humidifier (for up to the first 7 days of mechanical ventilation) or heated-water humidification. MEASUREMENTS: Occurrence of ventilator-associated pneumonia, endotracheal tube occlusion, duration of mechanical ventilation, lengths of intensive care and hospitalization, acquired multiorgan dysfunction, and hospital mortality. RESULTS: One hundred sixty-three patients were randomly assigned to receive humidification with an extended-use hygroscopic condenser humidifier, and 147 patients were randomly assigned to receive heated-water humidification. The two groups were similar at the time of randomization with regard to demographic characteristics, ICU admission diagnoses, and severity of illness. Risk factors for the development of ventilator-associated pneumonia were also similar during the study period for both treatment groups. Ventilator-associated pneumonia was seen in 15 (9.2%) patients receiving humidification with an extended-use hygroscopic condenser humidifier and in 15 (10.2%) patients receiving heated-water humidification (relative risk, 0.90; 95% confidence interval=0.46 to 1.78; p=0.766). No statistically significant differences for hospital mortality, duration of mechanical ventilation, lengths of stay in the hospital ICU, or acquired organ system derangements were found between the two treatment groups. No episode of endotracheal tube occlusion occurred during the study period in either treatment group. The total cost of providing humidification was $2,605 for patients receiving a hygroscopic condenser humidifier compared with $5,625 for patients receiving heated-water humidification. CONCLUSION: Our findings suggest that the initial application of an extended-use hygroscopic condenser humidifier is a safe and more cost-effective method of providing humidification to patients requiring mechanical ventilation compared with heated-water humidification.

Adolescent↗

High frequency of pseudobacteremia at a university hospital.

A prospective survey of all positive blood cultures was performed during a 6-month period at a 390-bed, tertiary-care teaching hospital in St Louis, Missouri. Data were collected from the clinical microbiology laboratory, medical records, and physicians caring for patients with positive blood cultures. Of 5,732 blood cultures, 261 (4.6%) were positive, and approximately half of these (51.3%) were categorized as false positive. Positive cultures were significantly more likely to be true positives if obtained from patients with malignancies or if they became positive within the first 48 hours of incubation.

Bacteremia↗

Mechanical ventilation with or without daily changes of in-line suction catheters.

The purpose of this study was to determine the safety and cost-effectiveness of not routinely changing in-line suction catheters for patients requiring mechanical ventilation. Patients were randomly assigned to receive either no routine in-line suction catheter changes (n = 258) or in-line suction catheter changes every 24 h (n = 263). The main outcome measure was the incidence of ventilator-associated pneumonia. Other outcomes evaluated included hospital mortality, acquired organ system derangements, duration of mechanical ventilation, lengths of intensive care and hospital stay, and the cost for in-line suction catheters. Ventilator-associated pneumonia was seen in 38 patients (14.7%) receiving no routine in-line suction catheter changes and in 39 patients (14.8%) receiving in-line suction catheter changes every 24 h (relative risk, 0.99; 95% CI, 0.66 to 1.50). No statistically significant differences for hospital mortality, lengths of stay, the number of acquired organ system derangements, death in patients with ventilator-associated pneumonia, or mortality directly attributed to ventilator-associated pneumonia were found between the two treatment groups. Patients receiving in-line suction catheter changes every 24 h had 1,224 catheter changes costing a total of $11,016; patients receiving no routine in-line suction catheter changes had a total of 93 catheter changes costing $837. Our findings suggest that the elimination of routine in-line suction catheter changes is safe and can reduce the costs associated with providing mechanical ventilation.

Adult↗

Patient transport from intensive care increases the risk of developing ventilator-associated pneumonia.

STUDY OBJECTIVE: To determine whether patient transport out of the ICU is associated with an increased risk of developing ventilator-associated pneumonia. DESIGN: Prospective cohort study. SETTING: ICUs of Barnes-Jewish Hospital, a university-affiliated teaching hospital. PATIENTS: Five hundred twenty-one ICU patients requiring mechanical ventilation for > 12 h. INTERVENTION: Prospective patient surveillance and data collection. MEASUREMENTS AND RESULTS: The primary outcome measure was the development of ventilator-associated pneumonia. A total of 273 (52.4%) mechanically ventilated patients required at least one transport out of the ICU while 248 (47.6%) patients did not undergo transport. Sixty-six (24.2%) of the transported patients developed ventilator-associated pneumonia compared with 11 (4.4%) patients in the group not undergoing transport (relative risk=5.5; 95% confidence interval [CI]=2.9 to 10.1; p<0.001). Multiple logistic regression analysis demonstrated that a preceding episode of transport out of the ICU was independently associated with the development of ventilator-associated pneumonia (adjusted odds ratio=3.8; 95% CI=2.6 to 5.5; p<0.001). Other variables independently associated with the development of ventilator-associated pneumonia included reintubation, presence of a tracheostomy, administration of aerosols, and male gender. CONCLUSIONS: We conclude that patient transport out of the ICU is associated with an increased risk for the development of ventilator-associated pneumonia.

APACHE↗

Nosocomial outbreak of gastroenteritis due to Salmonella senftenberg.

We describe a prolonged nosocomial outbreak of Salmonella senftenberg, an uncommon human pathogen. We detected 22 cases of infection due to S. senftenberg that occurred from March 1993 through November 1994 and involved 18 patients and four healthy employees. All infected persons had consumed food prepared by the hospital kitchen. The estimated attack rate for the period of the outbreak was 0.19-0.23 cases per 100,000 meals served. Infection control interventions included observation of food preparation, disinfection of kitchen devices, and education of food handlers. The consumption of lettuce (11 of 15 patients who could recount extended dietary histories vs. 4 of 20 controls; P = .005), cauliflower (5 of 15 vs. 0/20; P = .02), cottage cheese (4 of 15 vs. 0/20; P = .03), and deli turkey (8 of 15 vs. 0/20; P < .001) was associated with S. senftenberg infection. The isolates had identical antibiograms and pulsed-field gel electrophoretic patterns. Cultures of stool samples from food handlers as well as food items, kitchen devices, and kitchen surroundings were negative for S. senftenberg. Interruption of the outbreak occurred coincidentally with the institution of infection control measures. This prolonged outbreak of salmonellosis was probably related to contamination in the kitchen from turkey, with cross-contamination via equipment.

Adult↗

Mechanical ventilation with or without 7-day circuit changes. A randomized controlled trial.

OBJECTIVE: To determine whether a practice of not routinely changing ventilator circuits in patients who require prolonged mechanical ventilation is associated with an increased incidence of nosocomial pneumonia. DESIGN: Randomized controlled trial. SETTING: Intensive care units in two university-affiliated teaching hospitals. PATIENTS: 300 patients admitted to an intensive care unit who required mechanical ventilation for more than 5 days. INTERVENTION: Patients were randomly assigned to receive either no routine ventilator circuit changes or circuit changes every 7 days. MEASUREMENTS: The primary outcome measure was the incidence of ventilator-associated pneumonia. Other outcome measures included duration of mechanical ventilation, length of hospital stay, and hospital mortality. RESULTS: 147 patients were randomly assigned to receive no routine ventilator circuit changes, and 153 patients were randomly assigned to receive circuit changes every 7 days. The two groups were similar at the time of randomization with regard to demographic characteristics, intensive care unit admission diagnoses, and severity of illness. Ventilator-associated pneumonia was seen in 36 patients (24.5%) receiving no routine changes and in 44 patients (28.8%) receiving changes every 7 days (relative risk, 0.85 [95% CI, 0.55 to 1.17]). No statistically significant differences for hospital mortality, intensive care unit mortality, death during mechanical ventilation, death in patients with ventilator-associated pneumonia, or mortality directly attributed to ventilator-associated pneumonia were found between the two treatment groups (P > or = 0.11). Patients receiving changes every 7 days had 247 circuit changes costing a total of $7410; patients receiving no routine changes had a total of 11 circuit changes costing $330. CONCLUSION: The elimination of routine ventilator circuit changes can reduce medical care costs without increasing the incidence of nosocomial pneumonia in patients who require prolonged mechanical ventilation.

Adult↗

The effect of late-onset ventilator-associated pneumonia in determining patient mortality.

STUDY OBJECTIVE: To determine whether the development of late-onset ventilator-associated pneumonia (VAP) is associated with an increased risk of hospital mortality. DESIGN: Prospective cohort study. SETTING: ICUs of two university-affiliated teaching hospitals. PATIENTS: Three hundred fourteen patients admitted to an ICU who required mechanical ventilation for greater than 5 days. INTERVENTIONS: Prospective patient surveillance and data collection. MEASUREMENTS: The primary outcome measures were the development of late-onset VAP (ie, occurring > 96 h after intubation) and hospital mortality. RESULTS: Late-onset VAP was observed in 87 patients (27.7%). Thirty-four (39.1%) patients with late-onset VAP died during hospitalization compared with 85 patients (37.4%) without late-onset VAP (relative risk, 1.04; 95% confidence interval [CI], 0.76 to 1.43). Twenty patients (6.4%) developed late-onset VAP due to a "high-risk" pathogen (ie, Pseudomonas aeruginosa, Acinetobacter sp, Xanthomonas maltophilia) with an associated mortality rate of 65%. Stepwise logistic regression analysis identified five variables as independent risk factors for hospital mortality (p < 0.05): an organ system failure index of 3 or greater (adjusted odds ratio [AOR], 3.4; 95% CI, 2.0 to 5.8; p < 0.001), having a nonsurgical diagnosis (AOR, 2.1; 95% CI, 1.3 to 3.6; p = 0.002), a premorbid lifestyle score of 2 or greater (AOR, 1.8; 95% CI, 1.1 to 2.9; p = 0.015), acquiring late-onset VAP due to a "high-risk" pathogen (AOR, 3.4; 95% CI, 1.2 to 10.0; p = 0.025), and having received antacids or histamine type-2 receptor antagonists (AOR, 1.7; 95% CI, 1.0 to 2.9; p = 0.034). Additionally, we found the occurrence of late-onset VAP due to high-risk pathogens to be the most important predictor of hospital mortality among patients developing VAP (AOR, 5.4; 95% CI, 2.8 to 10.3; p = 0.009). CONCLUSIONS: Nosocomial pneumonia due to certain high-risk microorganisms is an independent risk factor for hospital mortality among patients requiring prolonged mechanical ventilation. We suggest that future investigations of late-onset VAP stratify patient outcomes according to the distribution of high-risk pathogens when reporting their results.

APACHE↗