A microscale device for measuring emissions from materials for indoor use.

Emission test chambers or cells are used to determine organic vapour emissions from construction products under controlled conditions. Polymeric car trim component emissions are typically evaluated using direct thermal desorption/extraction. The Microchamber/Thermal Extractor (mu-CTE, Markes International) was developed to provide both a complementary tool for rapid screening of volatile organic compound (VOC) emissions--suitable for industrial quality control--and a means for thermal extraction of larger, more representative samples of car trim components. To determine the degree of correlation between conventional emission test methods and the microchamber, experiments were carried out under different conditions of temperature, air change rate and sample conditioning time. Good quantitative and qualitative correlation was obtained for measurements at ambient temperature. Moreover, it was shown that ambient-temperature emissions data collected using the mu-CTE as rapidly as possible--i.e. with minimal or no sample conditioning time--nevertheless provided a reliable guide as to how well that material would perform in subsequent 3-day chamber tests of VOC emissions. The parameters found to have the greatest influence on data correlation for experiments carried out at elevated temperatures were the sample mass (for bulk emissions testing) and the conditioning time. The results also showed that, within the constraints of inherent sample homogeneity, the mu-CTE gave reproducible emissions data, despite its small sample size/capacity relative to that of conventional chambers. Preliminary results of modelling the air flow within a microchamber using computational fluid dynamics showed a high degree of turbulent flow and two potential areas of still air which could cause sink effects. However, the experimental data reported here and in previous studies showed enhanced recovery of semivolatile components from the mu-CTE relative to a recovery from a 1 m(3) conventional chamber. This indicates that if these areas of relatively still air are present within the microchamber, they do not appear to be significant in practice.

Journal Article↗

Influence of molecular parameters on the sink effect in test chambers.

UNLABELLED: The determination of the specific emission rates of individual products and materials under indoor-related conditions requires the use of climate-controlled emission test chambers. However, most chambers demonstrate an inherent sink effect, i.e. the released components undergo adsorption/desorption processes with construction materials. Furthermore, this sink effect is enhanced by introducing an adsorbing sample surface into the test chamber. The degree of adsorption, as well as the extent of the recovery, can vary significantly for different chambers and samples and also depends on the physical properties of the relevant substance. Whereas the sink effect caused by the chamber itself can be reduced by using appropriate construction materials, it is not possible to avoid the sink effect attributable to the actual sample. For this reason it is of importance to evaluate chambers and samples for possible sink effects, taking into consideration the physical properties of substances. This can be achieved by kinetic modeling of emission data and determination of rate constants. The kinetic parameters obtained from curve fitting were combined with molecular parameters and applied to multivariate statistics. The properties of three different chambers with and without sink could be compared by cluster analysis. Principal component analysis revealed that the sink effect essentially depends on the boiling point of the substances examined. PRACTICAL IMPLICATIONS: Emission test chambers are operated by research institutions and testing laboratories for different purposes. The determined emission rate value of a building product is a function of the chamber construction, the material to be tested and the molecular properties of the target compound. In this work it is demonstrated, which parameters have the main influence on the test result. Furthermore it is shown how multivariate statistical analysis can be applied to experimental data to characterize the sink effect under dynamic conditions. This new technique provides a suitable tool for the evaluation and comparison of test chambers.

Air Pollution, Indoor↗

Plastics additives in the indoor environment--flame retardants and plasticizers.

Phthalic acid esters and phosphororganic compounds (POC) are generally known as semivolatile organic compounds (SVOCs) and are frequently utilized as plasticizers and flame retardants in commercial products. In the indoor environment, both compound groups are released from a number of sources under normal living conditions and accumulate in air and dust. Therefore, inhalation of air and ingestion of house dust have to be considered as important pathways for the assessment of exposure in living habitats. Especially in the case of very young children, the oral and dermal uptake from house dust might be of relevance for risk assessment. A critical evaluation of indoor exposure to phthalates and POC requires the determination of the target compounds in indoor air and house dust as well as emission studies. The latter are usually carried out under controlled conditions in emission test chambers or cells. Furthermore, chamber testing enables the determination of condensable compounds by fogging sampling. In the case of automobiles, specific scenarios have been developed to study material emissions on a test stand or to evaluate the exposure of users while the vehicle is driving. In this review, results from several studies are summarized and compared for seven phthalic esters and eight POC. The available data for room air and dust differ widely depending on investigated compound and compartment. Room air studies mostly include only a limited number of measurements, which makes a statistical evaluation difficult. The situation is much better for house dust measurements. However, the composition of house dust is very inhomogeneous and the result is strongly dependent on the particle size distribution used for analysis. Results of emission studies are presented for building products, electronic equipment, and automobiles. Daily rates for inhalation and dust ingestion of phthalic esters and POC were calculated from 95-percentiles or maximum values. A comparison of the data with results from human biomonitoring studies reveals that only a small portion of intake takes place via the air and dust paths.

Journal Article↗

Flame retardants in the indoor environment -- Part II: release of VOCs (triethylphosphate and halogenated degradation products) from polyurethane.

Organophosphate esters, halogenated and non-halogenated, are frequently used for fire protection of building materials. With regard to toxicological profiles it is desired to avoid human exposure in the indoor environment. Moreover, some hazardous volatile organic compounds detected in indoor air are directly linked to the utilization of flame retardants. In this study, different polyurethane (PUR) products for building and indoor use treated with organophosphate flame retardants were tested in 1 m(3) emission test chambers. Emissions of flame retardants and degradation products were measured under living conditions. A PUR hard foam sample showed area-specific emission rates >100 microg/m(2) h for the compound triethylphosphate. During the tests several chlorinated degradation products of organophophorous flame retardants could be identified in the chamber air.

Air Pollution, Indoor↗

Diffusion studies of VOC mixtures in a building material.

Volatile organic compound (VOC) adsorption by indoor materials will reduce peak concentrations, and subsequent desorption will prolong the presence of a compound indoors. Diffusion within materials plays an important role in this context. The purpose of this paper is to present two experimental set-ups to study VOC diffusion, and to show corresponding experimental results. The Field and Laboratory Emission Cell (FLEC) is in both cases an integral part of the set-up. The mass flow of VOC mixtures across gypsum board is studied. Diffusion of less polar VOCs in gypsum board can be fast (diffusion coefficients of 0.001-0.003 m2/h). Diffusion coefficients of chlorinated compounds are correlated with boiling points and molecular areas. Different compounds show similar diffusion properties.

Adsorption↗

Phthalic esters in the indoor environment--test chamber studies on PVC-coated wallcoverings.

Phthalic acid esters are important additives in polyvinyl chloride (PVC) products. Since PVC plastisoles for the production of wallcoverings contain about 30% phthalic acid esters, it is a crucial question whether these products can contribute to the pollution of the indoor environment. In this study, the emission of several technically relevant phthalates from PVC-coated wallcoverings were measured in emission test chambers under standard room conditions. During a 14-day test period, both the chamber air concentrations and the condensation on a cooled plate (fogging) were determined. In the chamber air, maximum concentrations of 5.1 micrograms/m3 for di-n-butylphthalate (DBP), 2.08 micrograms/m3 for di-pentylphthalate (DPP) and 0.94 microgram/m3 for di-(2-ethylhexyl)phthalate (DEHP) were found. After 14 days of exposure, up to 60.4 micrograms DEHP and 17.7 micrograms DPP could be quantified on the cooled plates of the fogging apparatus. The amounts of DBP and DIBP were significantly lower. A simple exposure calculation indicated no specific risk of an increased phthalate exposure in rooms with PVC wallcoverings.