Alteration of ventricular fibrillation by propranolol and isoproterenol detected by epicardial mapping with 506 electrodes.

INTRODUCTION: We hypothesized that drugs which alter ventricular refractoriness or excitability produce quantifiable changes in ventricular fibrillation. METHODS AND RESULTS: We used a 528-channel mapping system to quantify the effects of the beta-antagonist, propranolol, and the beta-agonist, isoproterenol, on activation patterns in ventricular fibrillation. A plaque of 506 (22 x 23) electrodes spaced 1.12 mm apart and covering about 5% of the ventricular epicardium was sewn to the anterior right ventricle in 18 pigs (30 kg). Propranolol (0.25 to 0.4 mg/kg) increased the refractory period at a right ventricular epicardial site while isoproterenol (3 to 5 micrograms/min) shortened it. Ventricular fibrillation was induced by programmed stimulation, and unipolar electrograms were recorded from the 506 plaque electrodes for 2 seconds beginning 1, 15, and 30 seconds after the onset of fibrillation. Active epicardial recording sites were identified from the first derivative of the unipolar potentials (dV/dt) detected at each electrode. Then, neighboring active sites were grouped into activation fronts by computer analysis. In six pigs the effect of repeated inductions of ventricular fibrillation was assessed by comparing ventricular fibrillation after saline with a preceding control episode of fibrillation. Each activation front excited 40% +/- 46% of the mapped region before blocking. No changes were observed with saline and multiple inductions of fibrillation. In another six pigs, ventricular fibrillation after propranolol was compared with a preceding control episode of fibrillation. Ventricular fibrillation after propranolol exhibited a decreased activation rate per epicardial recording site and fewer activation fronts per second. There was no change in the amount of tissue excited by each activation front or the number of reentry cycles per activation front compared with control. In addition, there was no change in the maximum negative dV/dt detected per activation at an epicardial site. In six pigs ventricular fibrillation during isoproterenol was compared with control episodes of ventricular fibrillation before and 45 minutes after washout of the drug. The control episodes of fibrillation were not different from each other. Compared with control, ventricular fibrillation during isoproterenol exhibited an increased activation rate per epicardial site, an increased amount of tissue excited by each activation front, and an increased maximum negative dV/dt for each activation. There was no change in the number of activation fronts per second or the number of reentry cycles per activation front compared with control. CONCLUSION: Quantitative analysis revealed that propranolol and isoproterenol do not have symmetrically opposite effects on ventricular fibrillation. Propranolol decreased the number of activation fronts while isoproterenol increased the amount of tissue excited by each activation front. Thus, drugs that alter ventricular refractoriness or excitability alter ventricular fibrillation.

Animals↗

An automated technique for identification and analysis of activation fronts in a two-dimensional electrogram array.

Cardiac activation sequences are normally determined by (i) the detection and timing of local activations in cardiac electrograms, (ii) the grouping together of activations in different electrodes that are generated by the same activation fronts, and (iii) the construction by interpolation of isochronal maps showing the pathways of the activation fronts. This process is typically carried out by manual or semiautomated methods. These methods are usually adequate for stable, repeatable rhythms in normal hearts. However, in situations in which the electrograms are distorted, as in those recorded from abnormal myocardium, or the mapped rhythms are rapidly changing, as in ventricular fibrillation, they are tedious and time-consuming and yield results that are subjective and not repeatable from one investigator to another. Therefore, we developed a computer-based method for automating the identification and analysis of activation fronts recorded from a large array of electrodes. The electrodes are closely spaced (1 mm) so that interpolation is not required. Electrodes are identified as recording an activation when the temporal derivative of the potential is more negative than a user-specified value. Activations occurring less than a user-specified distance apart in time and space are identified as part of the same activation front. Characteristics of the activation fronts, such as their number, size, and the presence of reentry or collision, are then quantified. The differences between the results obtained by this automated method and those obtained by four human investigators was no greater than the differences in results among the four investigators themselves. Because the method is automated and algorithmic, it is both rapid and repeatable.

Algorithms↗

Evaluation of an automatic cardiac activation detector for bipolar electrograms.

The identification of local activation events in bipolar cardiac electrograms, the first step of isochronal map construction, is a time-consuming and difficult process. Owing to the variability among bipolar activation complexes and the lack of practical knowledge concerning the relationship of the bipolar waveform to action potential characteristics, a set of empirical rules to guide the assignment of local activation times have been adopted. A computer program, called AP, has been designed, which implements these rules in the form of a syntactic analyser. Canine epicardial recordings were used to evaluate AP by comparing local activation times, assigned by AP, with times assigned independently by three investigators. The Hermes-Cox model for detector evaluation and a bootstrap statistical method were used in conjunction with ROC analysis to evaluate the ability of AP to detect events. Analysis of discrepancies among investigator-assigned times showed that the reliabilities of AP event detection and AP-assigned times were comparable to those of the investigators. The methods used in system design and evaluation are applicable to a broad range of problems in the detection and localisation of waveform components.

Animals↗

Visualization of bioelectric phenomena.

Biomedical investigators are currently able to acquire and analyze physiological and anatomical data from three-dimensional structures in the body. Often, multiple kinds of data can be recorded simultaneously. The usefulness of this information, either for exploratory viewing or for presentation to others, is limited by the lack of techniques to display it in intuitive, accessible formats. Unfortunately, the complexity of scientific visualization techniques and the inflexibility of commercial packages deter investigators from using sophisticated visualization methods that could provide them added insight into the mechanisms of the phenomena under study. Also, the sheer volume of such data is a problem. High-performance computing resources are often required for storage and processing, in addition to visualization. This chapter describes a novel, language-based interface that allows scientists with basic programming skills to classify and render multivariate volumetric data with a modest investment in software training. The interface facilitates data exploration by enabling experimentation with various algorithms to compute opacity and color from volumetric data. The value of the system is demonstrated using data from cardiac mapping studies, in which multiple electrodes are placed in an on the heart to measure the cardiac electrical activity intrinsic to the heart and its response to external stimulation.

Algorithms↗

The assumptions of isochronal cardiac mapping.

Isochronal maps of cardiac activation are commonly used to study the mechanisms and to guide the ablative therapies of arrhythmias. Little has been written about the assumptions implicit in the construction and use of isochronal cardiac maps. These assumptions include the following: (1) the location of the recording electrodes is known with sufficient accuracy to determine the mechanism of an arrhythmia or to guide therapy; (2) a single, discrete activation time can be assigned to each recording electrode location; (3) the presence or absence of activation at an electrode site can be reliable ascertained, and when activation is present, the time of activation can be determined with sufficient accuracy to specify the mechanism of an arrhythmia or to guide therapy; and (4) the recording electrodes are close enough together that the activation sequence can be estimated with sufficient accuracy to determine the mechanism of an arrhythmia or to guide therapy. The manuscript reviews evidence that these assumptions may not always be true, and when they are not, the isochronal map may be misleading.

Arrhythmias, Cardiac↗