PubMed Health⌕ Search

Biomedical subjects

E W Saaski

Publications and source records attributed to E W Saaski.

2 recordsLinked to original sources

Detecting staphylococcal enterotoxin B using an automated fiber optic biosensor.

The Man-portable Analyte Identification System (MANTIS), the first fully automated, self-contained, portable fiber optic biosensor, was utilized for the detection of Staphylococcal Enterotoxin B (SEB), a bacterial toxin produced by Staphylococcus aureus that commonly causes food poisoning. Because of its remarkable toxicity and stability, SEB is considered a prime threat as a biological weapon of mass destruction. The assay for SEB was used to evaluate the MANTIS' ability to function in the presence of various environmental interferents. The sensor could reliably detect SEB spiked into liquid samples containing a variety of smoke particles. However, substantial interference occurred when SEB was mixed into matrices capable of adsorbing SEB, such as 1% solutions of clay, topsoil, or pollen. Of equal importance, none of the interferents produced false positives in the MANTIS. The MANTIS demonstrated the capability to perform simultaneous immunoassays rapidly in the field with little or no user intervention.

Biosensing Techniques↗

Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor.

A portable fiber-optic biosensor was used to detect Escherichia coli O157:H7 in seeded ground beef samples. The principle of the system is a sandwich immunoassay using cyanine 5 dye-labeled polyclonal anti-E. coli O157:H7 antibodies for generation of a specific fluorescent signal. Signal acquisition is effected by launching light from a 635-nm diode laser into a dual tapered 600-microm silica fiber. Fluorescent molecules within approximately 100 nm of the fiber surface are excited by the evanescent field, and a portion of the emission recouples into the fiber. A photodiode allows for quantitation of the collected emission light at wavelengths of 670 to 710 nm. Biotin-avidin interactions are used to attach polyclonal antibodies specific for E. coli O157:H7 to the final 7.5 cm of the fiber probe. The biosensor was able to detect E. coli O157:H7 to 3 to 30 CFU/ml in seeded ground beef samples. The reaction was highly specific. Signals with Listeria monocytogenes, Salmonella Typhimurium, or E. coli nonO157:H7 were 2 to 3% of those observed with a similar concentration of E. coli O157:H7. Assays were conducted at or near real-time with results obtained within 20 min of sampling.

Animals↗