Quantitative estimation of attenuation in ultrasound video images: correlation with histology in diffuse liver disease.

RATIONALE AND OBJECTIVES: To determine the relationship between the attenuation of backscatter intensity in B-scan images of the liver and diffuse liver disease in order to assess the usefulness of this method in providing quantitative objective characterization of diffuse liver diseases in general and in fatty liver in particular. METHODS: Twenty-four healthy volunteers and 28 patients with elevated liver enzyme levels who underwent liver biopsy were included in this study. An automatic far-field slope (FFS) algorithm that estimates the decrease in amplitude of the backscattered echo as a function of beam depth was implemented on the noncompensated image that was acquired on a commercial phased-array ultrasound system fitted to a custom-built interface card. The images were processed at a work-station. All scans were acquired repeatedly, read, and graded blindly by experienced ultrasound radiologists. Histology obtained via needle biopsy was reviewed without knowledge of the ultrasound findings. RESULTS: Analysis of the FFS data for fatty infiltration in all patient groups yielded a sensitivity of 67%, a specificity of 77%, a positive predictive value (PPV) of 77%, negative predictive value (NPV) of 67%, and an accuracy of 71%. The mean score of the ultrasound reviewers showed a sensitivity of 82%, a specificity of 66%, a PPV% of 68%, an NPV of 81%, and an accuracy of 72%. Normal FFS values (false-negative) were found in five patients with proved fatty infiltration. All of these patients had coexistent moderate to severe hepatic inflammation. However, FFS data in patients with uncomplicated (pure) fatty infiltration revealed a sensitivity of 100%, a specificity of 80%, a PPV of 89%, an NPV of 100%, and an accuracy of 92%. The best ultrasound score yielded a sensitivity of 100%, a specificity of 60%, a PPV of 80%, an NPV of 100%, and an accuracy of 85% in the same patients. CONCLUSIONS: The data demonstrate an excellent sensitivity (100%) of the FFS values in patients with uncomplicated fatty infiltration. This was also the only group of patients in whom the FFS score was superior to the radiologists' best score. The FFS method can be used as a tool to follow up the response to a clinical or research treatment and to obtain standardization of pattern interpretation independently of the individual reader.

Adolescent↗

Ultrasonic attenuation maps of liver based on a conventional B-scan and an amplitude loss technique.

The authors present a novel ultrasonic amplitude loss technique, using image processing techniques and designed for computation of local attenuation estimates. Three different estimation approaches were evaluated: the extended Prony, the maximum likelihood, and the least squares approaches. The latter two approaches were found to result in a much higher estimation error than that observed for the Prony method. The attenuation values in the normal population (49 subjects) were 0.44 +/- 0.03 dB/MHz/cm. Three hundred sixty-seven liver scans from 266 patients were evaluated. Hodgkin's lymphoma patients with liver involvement had attenuation values of 0.22 +/- 0.07 dB/MHz/cm. Low attenuation values also were observed for four patients with viral hepatitis (0.31 +/- 0.08 dB/MHz/cm). The detectability of other disease states was not increased by these global attenuation estimates; however, the results demonstrate possible potential uses for the proposed technique for the diagnosis of diffuse liver disease.

Adult↗

Local tissue attenuation images based on pulsed-echo ultrasound scans.

This paper presents a novel technique for creating images of local tissue attenuation. The original conventional B scan is traversed, one pixel at a time. In the vicinity of each pixel, a uniform area is determined and average attenuation is computed utilizing an extended modified Prony approach. B scans of tissue mimicking phantoms and in vivo human liver scans are used in order to illustrate the performance of the proposed algorithm. The results show good agreement between estimated and known attenuation values. Clinical studies demonstrate significant potential of the proposed technique, in particular for diagnosis of diffuse liver disease.

Algorithms↗