Mesh tube--constricted varicose veins used as bypass grafts for infrainguinal arterial reconstruction.

Varicose veins are generally deemed inappropriate graft material for arterial reconstructions despite their physiologic flow surface because of their large and irregular caliber. Size reduction by threading such veins in constricting tubes may create bypass grafts of suitable caliber as long as redundant wall material does not cause stenoses. Sixteen human varicose veins (mean +/- SD, 13 +/- 3 mm diameter) obtained after stripping operations were inserted into Dacron mesh tubes of 6 mm internal diameter. Paraffin casts of the distended veins showed a size reduction of 6.9 +/- 2.6 mm. Wall material formed folds in only two veins. In both cases, diameter reduction was more than 10 mm. However, the folds did not result in significant stenoses. Mesh-constricted varicose veins were used as bypass material in 11 infrainguinal arterial reconstructions. All externally supported segments showed satisfactory size reduction without stenoses or folds. One graft occluded 2 months after surgery. Two patients had to undergo reoperation after 2 and 16 months, respectively. None of the complications could be attributed to the constriction of veins. The remaining grafts are patent and functional after a mean of 17 months (range, 6 to 42 months). Considerable size reduction by external wrapping of varicose veins is possible without adverse side effects. Such constricted veins were used successfully as bypass grafts for infrainguinal arterial reconstructions.

Aged

Management of severe bronchial ischemia after bilateral sequential lung transplantation.

A case of severe diffuse bronchial ischemia after bilateral sequential lung transplantation is presented. A combination of initial conservative treatment with silicone stenting and late bilateral retransplantation under stable conditions resulted in good clinical outcome. Factors in decision making and technical aspects of the stenting procedure are discussed.

Adult

Doppler sonographic evaluation of the CarboMedics bileaflet valve prosthesis: one-year experience.

Between April 1989 and March 1991, 237 CarboMedics bileaflet valve prosthesis carriers (165 aortic and 72 mitral valves, mean age 54.4 years) were studied prospectively with pulsed- and continuous-wave Doppler at a mean interval of 11.4 months following surgery in order to establish ranges of normal flow velocities and pressure gradients. Physical examination revealed no signs of prosthetic dysfunction or heart failure. Postoperative left ventricular function as measured by fractional shortening was 37% for aortic valve carriers and 30% for mitral valve carriers (p = NS). Mean peak velocity (+/- SD) across the aortic valve was 2.6 m/sec (+/- 0.4) and calculated instantaneous peak pressure gradient ranged from 11 to 58 mmHg (mean 28.1 +/- 10.3). It has to be emphasized that occasional patients with normally functioning valve prostheses can show unusual high gradients. Ring diameters between 21 and 27 mm showed no significant difference with regard to flow velocities and pressure gradients, whereas in 19-mm valves, significantly higher values could be demonstrated. The 123 aortic valve carriers with normal left ventricular function (fractional shortening greater than 25%) showed significantly higher pressure gradients than the 19 patients with reduced left ventricular function (28.6 +/- 11.6 mmHg vs 16.2 +/- 5.1 mmHg, p less than 0.05). In the mitral position, the mean of peak velocity (+/- SD) was 1.7 +/- 0.4 m/sec and pressure half-time was 108 +/- 26 msec, representing a calculated valve area between 1.4 to 3.1 cm2 (mean orifice size 2.1 +/- 0.5 cm2). No significant difference between valves of different sizes was found.(ABSTRACT TRUNCATED AT 250 WORDS)

Aortic Valve

Improved biocompatibility of bioprosthetic heart valves by L-glutamic acid treatment.

Treatment of glutaraldehyde-fixed pericardium with L-glutamic acid and storage in bacteriostatic preservatives (paraben) stably antagonizes free, reactive aldehyde groups within the fixed bioprosthetic heart valve tissue. In 63-day subcutaneous implants in rats, the calcification rate of this treatment (13.3 +/- 2 mg calcium/g wt tissue) was markedly reduced as compared to conventionally treated tissue (169 +/- 24 mg/g; p less than 0.05). To test the influence of tissue-released toxic aldehydes on spontaneous endothelial cell ingrowth in vivo, vascular grafts (8-cm long, 6-mm diameter) from fixed pericardium treated with L-glutamic acid were interposed into the carotid arteries in ten sheep. They were compared to grafts from conventionally treated pericardium implanted at the contralateral side. Following 3 months of implantation, planimetry revealed 49% +/- 20% of the surface of conventionally preserved pericardium to be covered with red thrombus, but only 12% +/- 5% in L-glutamic acid treated pericardium (p less than 0.05). The ultrastructural findings of a closed endothelial cell layer on the graft surface reveals the new technique to be a promising approach towards increased biocompatibility of aldehyde-fixed bioprosthetic heart valves.

Animals

Endothelial cell lining of bioprosthetic heart valve material.

In this in vitro study, the growth properties of cultured endothelial cells on conventionally treated pericardial valve material were measured. These data were compared to endothelial cell proliferation on an alternatively treated valve material. This alternative preservation procedure was developed in order to bind free, residual glutaraldehyde in the valve tissue by reaction with L-glutamic acid. In order to optimize endothelial cell attachment and proliferation, fibronectin and fibrillar collagen type I were tested as surface precoating substances. Cell viability of the seeded cells was evaluated by means of proliferation kinetics, antithrombotic activity, and morphological appearance. Endothelial cell death occurred within the first 2 days after seeding on conventionally treated valve tissue, independent of the type of precoating. On alternatively treated tissue, regular endothelial cell proliferation was observed. Precoating with fibrillar collagen markedly increased endothelial cell attachment and proliferation as compared to fibronectin. Maintenance of antithrombotic activity of the seeded cells was proven by regular release of prostacyclin.

Animals

One and one-half year experience with unilateral and bilateral lung transplantation.

Lung transplantation has now become an established form of treatment for end-stage pulmonary parenchymal and vascular diseases. Despite its wide acceptance, technical aspects are still in discussion. We report on the initiation of our own lung transplant program and the technical changes we have performed during our first 1 1/2-year experience. During that period of time, we have performed 26 lung transplantations (16 single lung [SLTX] and 10 bilateral lung transplantations [BLTX]). Three-month survival for the whole group was 74% (69% for the SLTX group and 77% for the BLTX group). No instance of bronchial dehiscence was observed; however, there were eight cases of bronchial stenosis: six were managed by silicone stent insertion, one by bronchoplastic correction, and one by retransplantation. Changes in the technique of the bronchial anastomosis together with the addition of prednisone to the immediate postoperative immunosuppressive regime resulted in almost complete avoidance of these problems.

Adult

Closing sounds and related complaints after heart valve replacement with St Jude Medical, Duromedics Edwards, Björk-Shiley Monostrut, and Carbomedics prostheses.

OBJECTIVE: To measure the noise produced and related subjective complaints after implantation of four different mechanical heart valve prostheses and to identify further factors related to the patient and prosthesis that influence noise generation and complaints. DESIGN: Sound pressure was measured 5 and 10 cm and 1 m from the point of maximal impulse on the body surface by a calibrated meter in quiet rooms with either a decibel(A) filter or octave filters. The patients were asked about their complaints and examined physically. SETTING: The measurements were conducted in silent rooms of ear, nose, and throat departments. The patients had been operated on either in a university hospital or a community hospital. MAIN OUTCOME MEASURES: Sound pressures of frequency bands and sound pressures measured in dB(A) at various distances. Complaints registerd were: sleep disturbance, disturbance during daytime, "wants a less noisy prosthesis," and "can hear the closing click". PATIENTS: 143 patients after heart valve replacement with St Jude Medical (n = 35), Duromedics Edwards (n = 38), Carbomedics (n = 34) and Björk-Shiley Monostrut (n = 36) prostheses operated on between 1984 and 1988 were matched for valve position, ring size, and body surface area. RESULTS: Duromedics Edwards (33.5 (6) dB(A)) and Björk-Shiley Monostrut valves (31 (4) dB(A)) were significantly louder than St Jude Medical (24 (4) dB(A)) and Carbomedics (25 (6) dB(A)) prostheses (p = 0.0001) (mean (SD)). The louder valves were significantly more often heard by the patients (p = 0.0012) and caused more complaints both during sleep (p = 0.024) and during the daytime (p = 0.07). Patients with these valves were more likely to want a less noisy valve (p = 0.0047). Patients with symptoms were younger, had better hearing, and were more likely to be in sinus rhythm. As well as the type of prostheses, the valve diameter and body height also had an effect on sound emission. CONCLUSIONS: The intensity of the closing click of mechanical valve prostheses was significantly different for various designs. Patient complaints were related to the objectively measured sound pressure. Noise production should be considered when a mechanical valve is selected.

Adult

[The coronary sinus as a source of activated T-lymphocytes in patients after orthotopic heart transplantation].

Mononuclear cells are the component of blood responsible for allograft recognition, rejection and acceptance. Shifts in the patterns of various mononuclear cell subpopulations were often used as a diagnostic tool in detection of heart rejection. The specificity of mononuclear cell monitoring has remained a controversial point until today, because infections led to similar changes as organ rejection. In this study we investigated whether mononuclear cells taken from coronary sinus blood give more information about the immunological status of the transplanted heart than those taken from central verous blood. After endomyocardial biopsy, coronary sinus blood was sampled by catheterization under X-ray control. Blood from the right atrium was taken for control measurement. Mononuclear cells obtained by density gradient cytocentrifugation were stained with monoclonal fluorescein conjugated antibodies detecting CD4- (T helper)-, CD8- (T suppressor)-, CD25- (Interleukin-2 receptor), and the CD71- (Transferrin receptor) antigens. Endomyocardial biopsies were graded according to the Billingham scheme. In the absence of rejection, the phenotypes of mononuclear cells from the coronary sinus did not differ from those of right atrial cells. Mild rejection led to a statistically insignificant increase of CD4- CD25- and CD7-antigen bearing cells in the coronary sinus blood, whereas the CD8 positive cells remained stable as compared to mononuclear cells from the right atrium. However, patients with moderate rejection showed a significant elevation of CD4 positive cells and activated T-cells (CD15-, CD71-positive cells) in the coronary sinus as compared with cells from the right atrium. The T helper/suppressor ratio (Th/s-ratio) shifted towards the T-helper population.(ABSTRACT TRUNCATED AT 250 WORDS)

CD4-CD8 Ratio

Endothelial cell lining of bioprosthetic heart valve materials.

To investigate the conditions for endothelial cell lining of glutaraldehyde-treated bioprosthetic heart valves, we examined in vitro the growth properties of endothelial cells on clinically used pericardial valve material and on glutaraldehyde-fixed pericardium treated with L-glutamic acid. To improve endothelial cell attachment to the valvular surface, we precoated both materials either with fibronectin or with fibrillar collagen (95% type I, 5% type III). Toxicity of glutaraldehyde, released from clinically used valve material, caused endothelial cell death, independent of the type of precoating. Treatment of the valve material with L-glutamic acid resulted in regular endothelial cell proliferation. We found that collagenous precoating, compared with fibronectin precoating, markedly enhanced endothelial cell proliferation and attachment (p less than 0.05). Maintenance of antithrombogenic potency of the seeded cells on L-glutamic acid-treated valve material was proved by regular release of prostacyclin. We conclude that bioprosthetic heart valve materials can be lined with endothelial cells if toxic glutaraldehyde released from the bioprostheses is eliminated.

Animals

Aprotinin decreases release of 6-keto-prostaglandin F1 alpha and increases release of thromboxane B2 in cultured human umbilical vein endothelial cells.

Use of the proteinase inhibitor aprotinin significantly improves hemostasis and reduces bleeding after operations in which extracorporeal circulation is used. The mechanism of action, however, has been only partially clarified. In this work we investigated whether aprotinin influenced the production and release of the eicosanoids prostacyclin, measured as the stable metabolite 6-keto-prostaglandin F1 alpha, and thromboxane A2, measured as the stable metabolite thromboxane B2, from endothelial cells. Human umbilical vein endothelial cells were incubated with different concentrations of aprotinin (5.5, 20, 55, and 100 mumol/L). The levels of 6-keto-prostaglandin F1 alpha and thromboxane B2 were measured at baseline and after thrombin stimulation. A concentration-dependent effect of aprotinin on 6-keto-prostaglandin F1 alpha synthesis was demonstrated. After incubation with 100 mumol/L of aprotinin, a 90% reduction in 6-keto-prostaglandin F1 alpha production was seen (31.69 versus 307.44 picograms per million cells; p less than 0.001). Conversely, thromboxane B2 production showed a 345% increase after incubation with aprotinin (287.80 versus 83.82 picograms per million cells; p less than 0.0001). Since 6-keto-prostaglandin F1 alpha inhibits and thromboxane B2 strongly enhances platelet aggregation, it appears that one mechanism of the clinically observed effectiveness of aprotinin lies in the altered ratio of 6-keto-prostaglandin F1 alpha: thromboxane B2 in endothelial cells, which leads to enhanced platelet aggregation and improved vessel sealing.

6-Ketoprostaglandin F1 alpha

Implantation of in vitro endothelialized polytetrafluoroethylene grafts in human beings. A preliminary report.

To assess the impact of in vitro endothelialization on prosthetic graft patency, we performed femorotibial reconstruction in four patients. Polytetrafluoroethylene grafts (6 mm), lined with cultivated autologous endothelial cells, harvested from the veins of the forearm, were used. Autologous endothelial cells were harvested enzymatically and characterized by morphology and factor VII staining. After a cultivation period of 17 to 23 days, the cell count increased from 27 +/- 3 x 10(4) endothelial cells to 5.4 +/- 1.1 x 10(6). Endothelial cell seeding on polytetrafluoroethylene prostheses was then performed. To improve endothelial cell attachment to the graft surface, polytetrafluoroethylene grafts (60 to 70 cm; 6 mm diameter) were precoated with fibrin glue containing fibrin and fibronectin and the fibrinolysis inhibitor aprotinin. Seeding density of 49 +/- 10 x 10(3) endothelial cells per square centimeter yielded a preconfluent monolayer immediately after seeding, as demonstrated by scanning electron microscopy. A second cultivation period of 6 days, after seeding and before implantation, was necessary for establishment of a confluent monolayer and to allow for maturation of the endothelial cell cytoskeleton as well as production and excretion of extracellular matrix. Grafts endothelialized in vitro were implanted in four patients requiring femorotibial reconstruction. Scintigraphic studies with indium 111-labeled platelets demonstrated little or no platelet deposition, indicating persistent endothelialization. All grafts remained patent at 3 months after implantation.

Aged

Aprotinin increases release of von Willebrand factor in cultured human umbilical vein endothelial cells.

Through the perioperative administration of the proteinase inhibitor aprotinin, hemostasis can be improved and postoperative bleeding reduced after cardiac operations. The mechanism of action has been only partially clarified. The goal of our study was to investigate the influence of aprotinin on the synthesis of von Willebrand factor (vWF) in human endothelial cells. Human umbilical vein endothelial cells (HUVEC) were cultivated in vitro and incubated with different aprotinin concentrations (55, 100, and 215 mol/L). With all investigated aprotinin concentrations, there was an increase in vWF synthesis compared with basal secretion (p less than 0.001). When the HUVEC were preincubated with aprotinin and stimulated with thrombin, there was a further significant increase in vWF synthesis. HUVEC that, were first incubated with aprotinin and then stimulated with thrombin demonstrated a significant increase in vWF synthesis compared with basal secretion in nonincubated cells (p less than 0.0001). Also, compared with the cells that had received thrombin stimulation alone, the combination of aprotinin incubation and thrombin stimulation led to a significantly higher vWF concentration (p less than 0.05). Because vWF is necessary for the interaction with platelet factor glycoprotein Ib and platelet adhesion, the demonstrated increase in vWF synthesis could be one of the mechanisms of action of aprotinin leading to its blood-sparing effect.

Aprotinin

[Surgery of blunt heart trauma].

Between 1972 and 1990 11 patients--all but one of them with multiple injuries--were treated surgically for blunt cardiac trauma caused by traffic accident in about 90%. Myocardial rupture (n = 3), laceration of the pericardial sac (n = 1), mitral insufficiency (n = 5; one of them in combination with atrial septal defect), ventricular septal defect (n = 1) and myocardial aneurysm (n = 1) occurred. Patients with myocardial rupture and pericardial laceration died within 2 h after admission to hospital; the other patients were successfully treated by mitral valve replacement (n = 4), mitral valvuloplasty and repair of ASD, suture repair of VSD and resection of myocardial aneurysm in one case, respectively. The interval to operation was 8 months to 12 years. Whereas pericardial tamponade caused by rupture of the atrial or ventricular wall and injuries of main coronary vessels require immediate surgical intervention, valve insufficiencies, septal defects or myocardial aneurysms may be mostly treated at a later date. Improvement of logistic measurements and the suspicion of blunt cardiac trauma followed by immediate surgical intervention may reduce the mortality rate in cases of cardiac rupture.

Adolescent

[Video-endoscopic interventions in thoracic surgery].

Between October and December 1991 we performed videoendoscopic procedures, including resection of lung tissue, on 9 patients in our thoracic surgery unit. A lung measuring 15 x 18 was extirpated in 1 patient and parietal pleurectomy was performed after complicated pneumothorax in 4 patients. In one of these cases it was necessary to close a parenchymal leak and in 3 cases bullae had to be removed. Resection was undertaken in 4 patients for peripheral lung nodules, in one of them for metastases. Two patients proceeded to conventional lobectomy immediately after the frozen section results came through. Closure of lung parenchyma was carried out by means of the new ENDO-GIA stapler. Duration of the procedure was less than one hour except in the case of one patient. In one case it was necessary to use three cannulae. In the other cases two cannulae (one for videoendoscopy and fixating instrument, one for preparation instrument and stapler) sufficed for the operation to be undertaken without difficulty. This new technique brings all the known advantages of minimal invasive intervention to patients requiring thoracic surgery.

Adult

The determinants of elevated total plasma cholesterol levels in cardiac transplant recipients administered low dose cyclosporine for immunosuppression.

Elevated total plasma cholesterol level is a frequent finding after cardiac transplantation. To identify risk factors for the development of hypercholesterolemic states, we applied multivariate statistics in a logistic and linear manner. Six-month posttransplantation levels of total plasma cholesterol in 57 adult heart recipients were available for analysis. Maintenance immunosuppression was carried out with either cyclosporine and azathioprine or both agents plus low-dose steroids. Total plasma cholesterol levels were dichotomized for the logistic analysis (1) by the age- and sex-matched 75th and 90th percentiles of a reference population according to National Institutes of Health treatment guidelines and (2) by the cut point 250 mg/dl. Twelve potential risk factors were evaluated as covariates: recipient age, body weight after 6 months, body weight gain over 6 months, body mass index after 6 months, body mass index gain over 6 months, current cyclosporine dosage, trough level of cyclosporine in whole blood according to high-performance liquid chromatography after 6 months, cumulative cyclosporine dosage over 6 months, serum bilirubin, type of original cardiac disease, maintenance steroids, and steroid bolus treatment. Multivariate logistic regression yielded the type of original cardiac disease as a significant predictor of posttransplantation hypercholesterolemia exceeding the 90th percentile (p = 0.019) and of hypercholesterolemia exceeding 250 mg/dl (p = 0.032). Maintenance steroids were identified as a second significant cofactor (p = 0.069) for total plasma cholesterol levels exceeding 250 mg/dl. Multiple linear regression again revealed the type of original cardiac disease and maintenance steroids as significant predictors by p values of 0.005 and 0.013, respectively. Patients with coronary artery disease as the original cardiac pathology and low-dose maintenance steroids had the greatest risk for the development of elevated total plasma cholesterol levels after cardiac transplantation. However, the overall predictive quality of the linear model was limited (multiple r value 0.43), which indicates that other variables besides the tested ones attributed to elevated total plasma cholesterol levels. These results confirm the adverse role of maintenance steroids on posttransplantation hypercholesterolemia and demonstrate the type of original cardiac disease as the most important risk factor. They suggest that abnormalities of lipoprotein metabolism and dietary factors continue to affect total plasma cholesterol levels after cardiac transplantation.

Adult